2.6

Installing the plug-in power units in the 

M4-POWER power unit chassis

When replacing a defective plug-in power unit, only use a plug-in power unit 
of the M4-P-... 300W type 

(see on page 61 “Order numbers/product 

description”)

 

Remove the power supply cables.

Loosen the four screws used to fasten the plug-in power unit in the basic 
device and pull the unit out of the basic device, or remove the cover plate 
of the power unit slot.

Slide the new plug-in power unit all the way into the basic device along 
the mounting rails above and below.

Make sure that there is a good connection between the multiple plug of 
the plug-in power unit and the female multipoint of the system bus.

Screw the slotted-head screws in the front panel of the plug-in power unit 
flush with the frame of the basic device.

Connect the power supply cables.

Note: 

The tightening torque is

7 lb in. (0.791 Nm) for input connections.

11 lb in. (1.243 Nm) for all field wiring terminal blocks. 

Содержание MACH4000 Series

Страница 1: ...R 1 LS DA 2 3 4 5 6 7 8 LS DA LS DA LS DA LS DA LS DA LS DA LS DA P 1 LS DA 2 3 4 5 6 7 8 1 4 7 2 5 8 3 6 M4 FAST 8SFP P 1 2 3 4 5 6 7 8 1 4 7 2 5 8 3 6 P P1 P2 P3 P4 RM RL1 RL2 FAN RUN L D FDX 1000 A...

Страница 2: ...res described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the comp...

Страница 3: ...t area of basic board 24 1 5 2 Right area of basic board 25 1 6 Signal contact 26 1 7 Media modules 27 1 7 1 M4 8TP RJ45 27 1 7 2 M4 FAST 8TP RJ45 PoE 28 1 7 3 M4 FAST 8 SFP 28 1 7 4 M4 GIGA 8 SFP 28...

Страница 4: ...nstalling the M4 AIR plug in fan unit 44 2 6 Installing the plug in power units in the M4 POWER power unit chassis 45 2 7 Installing the media modules 46 2 8 Installing SFP XFP transceivers optional 4...

Страница 5: ...n the device when the housing is closed Close all empty slots with a covering panel Screw the power supply units to the housing before connecting the input voltage If you are using the M4 POWER power...

Страница 6: ...ion terminals for the supply voltage and the signal contact Do not touch the connection terminals for the supply voltage and the signal contact Close all empty slots with a covering panel Modules fans...

Страница 7: ...al data are maintained Only to be used in an environment with the pollution degree specified in the technical data Increased ambient temperature When you are operating the device in a closed switch ca...

Страница 8: ...he electrical installation may only be carried out by personnel trained for this purpose Note LED or LASER components in compliance with IEC 60825 1 2007 CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT Nati...

Страница 9: ...e regulations of member states with regard to electrical equipment to be used within specific voltage ranges 2004 108 EC EMC Directive of the European Parliament and the council for standardizing the...

Страница 10: ...ss A digital device in line with part 15 of the FCC regulations These requirements are designed to provide sufficient protection against interference when the device is being used in a business enviro...

Страница 11: ...Command Line Interface user manual The Industrial HiVision Network Management Software provides you with additional options for smooth configuration and monitoring Simultaneous configuration of multip...

Страница 12: ...12 Installation MACH4000 Release 14 06 2013 Legend The symbols used in this manual have the following meanings Listing Work step Subheading...

Страница 13: ...tches and the power unit chassis are suitable for mounting in the 19 rack The devices allow you to set up switched industrial Ethernet networks that conform to the IEEE 802 3 standard The HIPER Ring r...

Страница 14: ...module 3 plug in unit 3 Media module 1 plug in unit 4 Basic board integrated ports 6 1 to 6 16 5 Media module 4 plug in unit 6 Media module 2 plug in unit 7 Back of device power supply unit 8 External...

Страница 15: ...DA LS DA LS DA LS DA P 1 LS DA 2 3 4 5 6 7 8 1 4 7 2 5 8 3 6 M4 FAST 8SFP P 1 2 3 4 5 6 7 8 1 4 7 2 5 8 3 6 P P1 P2 P3 P4 RM RL1 RL2 FAN RUN L D FDX 1000 AN TP FO RING PORT STBY LED TEST 2 1 1 2 3 4...

Страница 16: ...0 1000 Mbit s TP SFP combo ports 10 100 1000 Mbit s XFP slots 10 Gbit s 10 100 Mbit s 10 100 1000 Mbit s 4002 48 4G 48 16 4 4a a SFP 1000 Mbit s 4b b M4 8TP RJ45 M4 8TP RJ45 PoE or M4 FAST 8 SFP 137 W...

Страница 17: ...4 Gigabit Ethernet ports combo ports i e SFP slots for 1000BASE SX or 1000BASE LX and RJ45 sockets for 10 100 1000BASE TX media module 5 and 16 Fast Ethernet ports 10 100BASE TX media module 6 In the...

Страница 18: ...OWER power unit chassis The M4 POWER power unit chassis enables redundant power supply The power supply cable s between M4 POWER and MACH4000 is are connected at the back of the MACH4000 device M4 POW...

Страница 19: ...e DC modules M4 VDC 300W are grounded via the 3 pin DC socket connection Figure 8 Plug connections at the DC socket external voltage supply 1 3 1 Supply voltage on the back of the device Plug in power...

Страница 20: ...the back of the MACH4000 device using the power supply cable supplied with the M4 P xx plug in power units Figure 9 M4 POWER power unit chassis front side of the device mounting with up to 3 power un...

Страница 21: ...lling the M4 AIR plug in fan unit on page 54 M4 AIR Plug in fan for MACH4000 switch chassis without temperature sensor for use in ambient temperatures up to a maximum of 60 C M4 AIR L Plug in fan for...

Страница 22: ...rs on the Ethernet connections Temperature difference The difference between the ambient temperature and the circuit board PCB temperature is primarily independent of the ambient temperature MACH4000...

Страница 23: ...Basic board MACH4002 48G Figure 15 Basic board MACH4002 24G 3X MACH4000 device Printed circuit board PCB temperature threshold value MACH4002 48 4G Ambient temperature 20 K MACH4002 24G 48G Ambient te...

Страница 24: ...Eight Gigabit Ethernet ports Combo in MACH4002 24G and MACH4002 48G There are eight Gigabit Ethernet ports ports number 6 1 to 6 8 for connecting network segments on the left side of the basic board T...

Страница 25: ...on the right side of the basic board These ports are RJ45 sockets 16 Gigabit Ethernet ports in MACH4002 48G and MACH4002 48G 3X There are sixteen 10 100 1000BASE TX ports ports number 6 1 to 6 16 for...

Страница 26: ...tact The signal contact is a potential free relay contact The device allows you to perform remote diagnosis via the signal contact In the process the device signals events such as a line interruption...

Страница 27: ...TP RJ45 PoE M4 FAST 8 SFP M4 GIGA 8 SFP MACH4002 48 4G 0 4 Media modules 0 4 Media modulesa a Note the PoE capacity limits see Maximum number of ports and media modules and maximum PoE power on page 1...

Страница 28: ...ble The power is supplied via the data lines The individual ports are not electrically insulated from each other 1 7 3 M4 FAST 8 SFP The M4 FAST 8 SFP media module has eight 100BASE FX ports SFP slots...

Страница 29: ...on page 61 1 8 SFP XFP transceiver Figure 19 SFP transceiver and XFP transceiver 1 Fast Ethernet F O SFP transceiver 2 Gigabit Ethernet F O SFP transceiver 3 10 Gigabit Ethernet F O XFP transceiver S...

Страница 30: ...utonegotiation activated The socket housing is electrically connected to the front panel The pin assignment corresponds to MDI X 1 9 2 100 Mbit s F O connection These ports are SFP slots 100 MBit s F...

Страница 31: ...plex mode Default setting Full duplex Note Make sure that you connect SR ports exclusively with SR ports LR ports exclusively with LR ports ER ports exclusively with ER ports and ZR ports exclusively...

Страница 32: ...Display elements for device state and port display state 1 Device state 2 Port display state 1 10 1 Device state These LEDs provide information about conditions which affect the operation of the whol...

Страница 33: ...oltage 3 or voltage too low at external input 3 Green flashing Supply voltage 3 is present but the plug in power unit is reporting an error LED Display Color Activity Meaning P4 Power supply Green Lig...

Страница 34: ...eporting an error or the plug in fan unit is not installed LED Display Color Activity Meaning RUN BOOT RUN Green Lights up The system is operational Green Lights up The system is booting None The syst...

Страница 35: ...g light The initialization phase is running after a restart LED Display Color Activity Meaning 1 Green Service LED LED Display Color Activity Meaning 2 PoE status Green Lights up The port LEDs of the...

Страница 36: ...it s is active Green Lights up Transmission speed 100 Mbit s is active Yellow Lights up Transmission speed 1000 Mbit s is active green yellow flashing Transmission speed 10000 Mbit s is active LED Dis...

Страница 37: ...interface is not electrically isolated from the supply voltage Figure 21 Pin assignment of the V 24 interface and the DB9 connector Note You will find the order number for the terminal cable which is...

Страница 38: ...s an interface for the local connection of an AutoConfiguration Adapter It is used for saving loading the configuration and for loading the software See Accessories on page 63 Figure Pin Operation 1 V...

Страница 39: ...cting the supply voltage starting up Wiring and assembling the signal contact Connecting the data lines Note Read the safety guidelines under Safety instructions on page 5 2 1 Unpacking and checking C...

Страница 40: ...o the front panel as a conductor 2 2 2 Mounting on a flat surface Before operating the device on a flat surface such as a table fasten the housing feet supplied at a distance of 2 cm from the corners...

Страница 41: ...ail 3 19 switching cabinet On delivery two brackets are attached to the sides of the device see figure below NOTE VIBRATIONS Assemble the device in a 19 switch cabinet on sliding mounting rails Non ad...

Страница 42: ...all the way into the basic device along the mounting rails above and below Make sure that there is a good connection between the multiple plug of the plug in power unit and the female multipoint of th...

Страница 43: ...te the external power supply from the M4 POWER power unit chassis Remove all the plug in power units from the M4 POWER power unit chassis Connect one end of the M4 POWER CABLE to the MACH4000 device C...

Страница 44: ...g in power units 1 Plug in power unit 1 2 Plug in power unit 2 3 Not used 4 M4 POWER power unit chassis front of device 2 5 Installing the M4 AIR plug in fan unit Slide the new plug in fan unit all th...

Страница 45: ...t out of the basic device or remove the cover plate of the power unit slot Slide the new plug in power unit all the way into the basic device along the mounting rails above and below Make sure that th...

Страница 46: ...talled while the network is operating hot swappable Figure 25 Installing the media modules 1 Step 1 2 Step 2 3 Step 3 Note Note the ESD guidelines on see on page 8 and the safety instructions on see o...

Страница 47: ...3 47 Insert the media module as far as it will go into the desired slot by closing the blue insertion catches See Fig above step 3 Screw the two knurled screws in the front panel of the media module f...

Страница 48: ...SFP XFP transceiver with the lock closed into the socket until it latches audibly in place 2 9 Connecting the supply voltage starting up Remarks Observe the information about the voltages to be conne...

Страница 49: ...WG12 For the current conductors at the voltage input of the AC DC plug in power units use a cable cross section of at least 1 0 mm North America AWG16 Connect the power supply cable to the power input...

Страница 50: ...lowing condition is also reported in RM mode Ring redundancy reserve is available On delivery there is no ring redundancy monitoring Pull the terminal block off the Switch and connect the signal lines...

Страница 51: ...user manual on the CD DVD Default settings IP address The device looks for the IP address using DHCP Password for management Login user password public read only Login admin password private read and...

Страница 52: ...losed relay contacts and the switching function depending on the frequency of the switching operations Hirschmann is continually working to improve and develop our software You should regularly check...

Страница 53: ...the selected media module from the slot by pulling the blue insertion catches see Fig above steps 1 and 2 Pull the media module out of the slot see Fig above step 3 Close the slot with a cover panel...

Страница 54: ...AIR or M4 AIR L plug in fan unit Pull the plug in fan unit out a few centimeters and wait until the fan comes to a halt before pulling it all the way out CAUTION ROTATING PARTS After the device is swi...

Страница 55: ...rrent consumption M4 S AC DC 300W M4 S 24VDC 300W M4 S 48VDC 300W max 1 7 A 240 V AC max 4 0 A 100 V AC max 16 0 A 24 V DC max 20 0 A 19 2 32 V DC max 8 0 A 48 V DC max 10 A 38 4 60 V DC M4 P AC DC 30...

Страница 56: ...4 GIGA 8 SFP With M4 AIR plug in fan unit Ambient air 0 C 60 C With M4 AIR L plug in fan unit Ambient air 0 C 40 C Pollution degree 2 Protection classes Laser protection Protection class Class 1 accor...

Страница 57: ...Dimensions Interfaces Interface Design MACH4002 Signal contact 4 pin pluggable terminal block V 24 access 1 x RJ11 socket USB interface For connecting an AutoConfiguration Adapter ACA 21 USB mm inch 4...

Страница 58: ...German Lloyd Classification Construction Guidelines VI 7 3 Part 1 Ed 2001 Yes Stability Vibration IEC 60068 2 6 Test FC test level according to IEC 61131 2 Yes Germanischer Lloyd Guidelines for the Pe...

Страница 59: ...dB 14 42 km 0 4 dB km 3 5 ps nm km LH LC LH 1550 nm 9 125 m 5 22 dB 23 80 km 0 25 dB km 19 ps nm km LH LC LH 1550 nm 9 125 m 15 30 dB 71 108 km 0 25 dB km 19 ps nm km LH LC LH 1550 nm 9 125 m 15 30 d...

Страница 60: ...2 6 Btu IT h 402 7 Btu IT h 426 6 Btu IT h M4 POWER 0 0 W 0 0 Btu IT h M4 S AC DC 300W 230 V M4 S AC DC 300W 110 V M4 S 24VDC 300W M4 S 48VDC 300W 350 0 W 370 0 W 380 0 W 380 0 W 170 7 Btu IT h 238 9...

Страница 61: ...upply cable for connecting power unit chassis to basic switch device Product description Description Order No Basic devices MACH4002 48 4G L2P MACH4002 48 4G L3E MACH4002 48 4G L3P Switch chassis 48 4...

Страница 62: ...up to a maximum of 40 C 942 005 001 Plug in power units M4 S AC DC 300W Plug in AC power unit 300 W for basic switch device 943 870 001 M4 S 24VDC 300W Plug in 24 V DC power unit single current for sw...

Страница 63: ...er software HiOPC 943 055 001 10 Gigabit Ethernet XFP transceiver M XFP SR LC 0 C 60 C 943 917 001 M XFP LR LC 0 C 60 C 943 919 001 M XFP ER LC 0 C 60 C 943 920 001 M XFP ZR LC 0 C 60 C 943 921 001 Gi...

Страница 64: ...nts EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement EN 60950 1 Information technology equipment Safety Part 1 General requirements EN 6113...

Страница 65: ...E mail inet ap belden com Hirschmann Competence Center The Hirschmann Competence Center is ahead of its competitors Consulting incorporates comprehensive technical advice from system evaluation throug...

Страница 66: ...66 Installation MACH4000 Release 14 06 2013...

Страница 67: ...67 Installation MACH4000 Release 14 06 2013...

Страница 68: ......

Отзывы: