Appendix
IRD 8500/..
Intergrated Receiver Decoder
6 - 11
Message:
SMPT: Fatal: Couldn_t spawn mailclient
Cause:
Something is wrong with the mail client
Solution:
Change the device and contact one of our service centers.
Message:
Supply voltage failure.
Cause:
Unknown.
Solution:
Change the device and contact one of our service centers.
Message:
Temperature too high.
Cause:
The housing temperature is above 70 degrees Celsius.
Solution:
Verify that the vents are not blocked.
Message:
Temperature too low.
Cause:
The temperature is below 0 degrees Celsius or hardware failure.
Solution:
Verify that the ambient temperature of the equipment is in the
operation range of 0 ... 45 degrees Celsius
OR Change the device.
Message:
Too many guests online, disconnect.
Cause:
More than 5 guests have tried to log in.
Solution:
Reduce the number of guests.
Message:
Twisted pair disconnected / Incorrect mail settings
Cause:
Broken connection
OR invalid settings.
Solution:
Verify that the network connection and the mail configuration (IP
number, mail address, host, account) are correct.
Message:
xx V power supply failure.
Cause:
Unknown.
Solution:
Change the device and contact one of our service centers.
NOTE:
NOTE:
NOTE:
NOTE:
Under normal conditions most network errors will cause the BS8000
to make a reset and fix the problem automatically.