Installation EAGLE20/30
Release 12 03/2021
45
6
Disassembly
6.1
Removing the device
Disconnect the data cables.
Disable the supply voltage.
Disconnect the terminal blocks.
Disconnect the grounding.
To remove the device from the DIN rail, press the device downwards and
pull it out from under the DIN rail.
Figure 9: Removal from the DIN rail
WARNING
ELECTRIC SHOCK
Disconnect the grounding only after disconnecting all other cables.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.