62
Installation BAT-R
Release 09 03/2017
7.7
EMC and immunity
MCS13
2 dBm
-77 dBm
MCS14
2 dBm
-75 dBm
MCS15
1 dBm
-73 dBm
MCS16
8 dBm
-92 dBm
MCS17
8 dBm
-91 dBm
MCS18
8 dBm
-89 dBm
MCS19
8 dBm
-84 dBm
MCS20
3 dBm
-81 dBm
MCS21
2 dBm
-77 dBm
MCS22
1 dBm
-75 dBm
MCS23
1 dBm
-73 dBm
EMC interference
immunity
EN 61000-4-2
Electrostatic discharge
Contact discharge, test level 4
± 8 kV
Air discharge, test level 4
± 15 kV
EN 61000-4-3
Electromagnetic field
80 MHz ... 1000 MHz
20 V/m
1400 MHz ... 2700 MHz
10 V/m
EN 61000-4-4
Fast transients (burst), test level 4
DC power line
± 4 kV
AC Power Line
± 4 kV
Data line
± 4 kV
EN 61000-4-5
Voltage surges
DC power line
± 2 kV line/ground; ± 1 kV line/line
AC Power Line
± 4 kV line/ground; ± 2 kV line/line
Data line, shielded
± 4 kV line/ground
Data line, unshielded
± 2 kV line/ground
Data line, unshielded
± 1 kV line/line
EN 61000-4-6
Conducted interference voltages, test level 3
150 kHz ... 80 MHz
10 V
EN 61000-4-9
Pulse magnetic fields
300 A/m
IEEE 802.11n
Bandwidth 5.180 GHz to 5.825 GHz
Coding
Typical transmit power
Typical receiving sensitivity