background image

Part 

No. 

4801-5801 

Rev. 

4-2010 

    Page 

6

 of 

24

 

 

 

Super Saver XL Heater Maywick 

 

 

Limited Warranty 

4. Warranty 

The GSI Group, LLC. (“GSI”) warrants products which it manufactures to be free of defects in 
materials and workmanship under normal usage and conditions for a period of 12 months after 
sale to the original end-user or if a foreign sale, 14 months from arrival at port of discharge, 
whichever is earlier.  The end-user’s sole remedy (and GSI’s only obligation) is to repair or 
replace, at GSI’s option and expense, products that in GSI’s judgment, contain a material defect in 
materials or workmanship.  Expenses incurred by or on behalf of the end-user without prior 
written authorization from the GSI Warranty Group shall be the sole responsibility of the end-user. 

 

Warranty Extensions:

  The Limited Warranty period is extended for the following products: 

 

Product

Warranty Period

AP Fans and 
Flooring 

Performer Series Direct Drive  
Fan Motor 

  3 Years 

All Fiberglass Housings 

 Lifetime 

All Fiberglass Propellers 

 Lifetime 

Cumberland 
Feeding/Watering 
Systems 

Feeder System Pan Assemblies 

  5 Years ** 

Feed Tubes (1.75" & 2.00") 

10 Years * 

Centerless Augers 

10 Years * 

Watering Nipples 

10 Years * 

Grain Systems 

Grain Bin Structural Design 

  5 Years 

Grain Systems 
Farm Fans 
Zimmerman

 

Portable & Tower Dryers 

  2 Years 

Portable & Tower Dryer Frames 
and Internal Infrastructure † 

  5 Years 

 

GSI further warrants that the frame, basket and excluding all auger and auger drive components of the portable 
and tower dyer shall be free from defects in materials for a period of time beginning on the twelfth (12

th

) month 

from the date of purchase and continuing until the sixtieth (60

th

) month from the date of purchase (extended 

warranty period). During the extended warranty period, GSI will replace the frame or basket components that 
prove to be defective under normal conditions of use without charge, excluding the labor, transportation, and/or 
shipping costs incurred in the performance of this extended warranty. 

Conditions and Limitations: 

THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET 
FORTH ABOVE.  SPECIFICALLY, GSI MAKES NO FURTHER WARRANTY OF ANY KIND, EXPRESS OR 
IMPLIED, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE OR USE IN CONNECTION WITH:  (i) PRODUCT MANUFACTURED OR SOLD BY 
GSI OR (ii) ANY ADVICE, INSTRUCTION, RECOMMENDATION OR SUGGESTION PROVIDED BY AN 
AGENT, REPRESENTATIVE OR EMPLOYEE OF GSI REGARDING OR RELATED TO THE 
CONFIGURATION, INSTALLATION, LAYOUT, SUITABILITY FOR A PARTICULAR PURPOSE, OR DESIGN 
OF SUCH PRODUCTS. 

GSI shall not be liable for any direct, indirect, incidental or consequential damages, including, without 
limitation, loss of anticipated profits or benefits.  The sole and exclusive remedy is set forth in the 
Limited Warranty, which shall not exceed the amount paid for the product purchased.  This warranty is 
not transferable and applies only to the original end-user.  GSI shall have no obligation or responsibility 
for any representations or warranties made by or on behalf of any dealer, agent or distributor. 

GSI assumes no responsibility for claims resulting from construction defects or unauthorized 
modifications to products which it manufactured.  Modifications to products not specifically delineated in 
the manual accompanying the equipment at initial sale will void the Limited Warranty. 

This Limited Warranty shall not extend to products or parts which have been damaged by negligent use, 
misuse, alteration, accident or which have been improperly/inadequately maintained.  This Limited 
Warranty extends solely to products manufactured by GSI.   

Prior to installation, the end-user has the responsibility to comply with federal, state and local codes which apply to the 
location and installation of products manufactured or sold by GSI.

 

 

* Warranty prorated from list price: 
        0 to 3 years – no cost to end-user 
        3 to 5 years – end-user pays 25% 
        5 to 7 years – end-user pays 50% 
        7 to 10 years – end user pays 75% 
 
** Warranty prorated from list price: 
        0 to 3 years – no cost to end-user 
        3 to 5 years – end-user pays 50% 
 
  † Motors, burner components and    
     moving parts not included. Portable  
     Dryer screens included. Tower Dryer  
     screens not included. 

Содержание Maywick SS-225-XL

Страница 1: ...upteurs electriques 3 Etegnex toute flamme hue 4 Contactez immediatement votre compangie de gaz FOR YOUR SAFETY Do not store or use gasoline or any flammable vapors and liquids in the vicinity of this...

Страница 2: ...lvents paint thinner dust particles or unknown chemicals Failure to follow these instructions may result in a fire or explosion property damage personal injury or loss of life WARNING Not for home or...

Страница 3: ...tructions Model No Maximum Input Ventilation air required to support combustion SS 225 XL 225 000 BTUH 65 9 kW 1000 CFM 1699 m3 hr LP Propane Gas Maximum 14 in W C 34 8 mbar and minimum 12 5 in W C 31...

Страница 4: ...be used for heating where flammable liquids and vapors are stored or used 11 Inadequate gas volume and or pressure will directly influence the combustion efficiency of the heater Adequate gas volume a...

Страница 5: ...ect heater and gas connections periodically for gas leaks with an approved gas leak testing solution soap and water work well 6 Keep heater clean at all times A Open doors and blow out dust with high...

Страница 6: ...ions THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH ABOVE SPECIFICALLY GSI MAKES NO FURTHER WARRANTY OF ANY KIND EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION...

Страница 7: ...eveling Adjust cables or chains as required to level the heater Use a carpenter s level to check that the heater is level 5 3 Installing Dual Flare Duct Fold Dual Flare duct to shape as shown in Fig 1...

Страница 8: ...heater will operate every time power is supplied and the on off switch is activated If an external thermostat is to be used See Component Wiring Diagram the heater will operate only when power is sup...

Страница 9: ...rectangle and fasten around exhaust outlet on front of heater with sheet metal screws provided 9 Place heater on support bracket Support bracket must be level before heater is set in place 10 Slide t...

Страница 10: ...oor cover in slots on heater door and slide down This will lock the cover in place on the door See Detail F Repeat this step for the second door 15 To continue with installation of your heater see Use...

Страница 11: ...Part No 4801 5801 Rev 4 2010 Page 11 of 24 Super Saver XL Heater Maywick COMPONENT AND WIRING DIAGRAM 230 Volts A C 50 Hz Single Phase 8 Component and Wiring Diagram...

Страница 12: ...INE VOLTAGE THERMOSTAT 10 AMP FUSE ON OFF TRANSFORMER 24 VAC 40VA 50 60 Hz LINE VOLTAGE LOW LINE UNITED TECHNOLOGIES Hot Surface Ignition Control FLAME SENSOR PROBE GND REDUNDANT VALVE MAIN VALVE HIGH...

Страница 13: ...ed below will help determine if system is operating properly The igniter will warm up and glow bright red The main burner flame will ignite The main burner flame will continue to burn after the ignite...

Страница 14: ...gnition sequence when the false flame is no longer present 4 Status Indicator Flashing Four Times When the status indicator LED shows the repeating error code of four flashes the control has gone into...

Страница 15: ...Part No 4801 5801 Rev 4 2010 Page 15 of 24 Super Saver XL Heater Maywick 10 4 Chart 1 First Visual Check Chart 1 First Visual Check...

Страница 16: ...Part No 4801 5801 Rev 4 2010 Page 16 of 24 Super Saver XL Heater Maywick 10 5 Chart 2 Second Visual Check Chart 2 Second Visual Check NOTE All voltage readings 10 15...

Страница 17: ...Part No 4801 5801 Rev 4 2010 Page 17 of 24 Super Saver XL Heater Maywick 10 6 Chart 3 Third Visual Check Chart 3 Third Visual Check...

Страница 18: ...000 4 x 12 160 000 48 b c 2 2 x 40 000 2 x 12 80 000 24 c e 1 1 x 40 000 1 x 12 40 000 12 b d 1 1 x 40 000 1 x 12 40 000 12 b f 1 1 x 40 000 1 x 12 40 000 12 c g 1 1 x 40 000 1 x 12 40 000 12 2 Determ...

Страница 19: ...500 7200 6700 5500 4600 3783 3432 Table values given in BTUH 1000 To convert to kW multiply table values by 0 3 1 inch 25 4 mm Pipe Sizes Determined For Diagram Pipe Section Max Gas Capacity Value Det...

Страница 20: ...date of manufacture voltage frequency gas type inside or outside mount and whether the heater is constructed of galvanized or stainless steel 1045 1305 Natural Gas 1045 0100 LP Propane Gas 1021 2501 0...

Страница 21: ...Super Saver XL Heater Maywick 3004 6000 3002 5001 24 V 3003 5010 6401 1308 1041 3066 1041 1491 1009 1500 1021 1497 1021 1496 Refer to Model No for Orifice type 0408 4492 1021 1495 1004 1422 6401 0226...

Страница 22: ...Rev 4 2010 Page 22 of 24 Super Saver XL Heater Maywick 0404 4486 6401 2879 6401 1318 0408 1131 3504 4007 3001 1740 3017 3076 240 Volt Heater Plate 3008 2258 3006 1580 1042 2693 3591 0100 1902 1138 30...

Страница 23: ...Part No 4801 5801 Rev 4 2010 Page 23 of 24 Super Saver XL Heater Maywick NOTES...

Страница 24: ...Copyright 2008 by Group Printed in the USA...