![HiP 25D815 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/hip/25d815/25d815_instructions-parts-list-manual_2137629028.webp)
Repair
28
3A6828B
Repair
Replacing the Transducer
See
Kits and Accessories
, on page 25, for transducer
kit numbers.
1. Follow the
Pressure Relief Procedure
on page 11.
2. Turn the disconnect switch (8) to the OFF position.
3. Disconnect the transducer cable (R) from the trans-
ducer (S). (See F
IG
. 1 on page 8.)
4. Replace the transducer (S) near the pump’s outlet
port (M).
5. Connect the transducer cable (R) to the new trans-
ducer (S).
6. Turn the disconnect switch (8) to the ON position.
Replacing the Electronic Air
Regulator
See
Kits and Accessories
, on page 25, for air regula-
tor kit numbers.
1. Follow the
Pressure Relief Procedure
on page 11.
2. Turn the disconnect switch (8) to the OFF position.
3. Disconnect the PT2020 from the AC outlet.
4. Open the enclosure.
5. Remove the M12 cable (2) from the top of the air
regulator (1).
6. Disconnect the hoses and fittings (3) from the sides
of the air regulator (1).
7. Loosen the four screws (5) on the base (4) of the air
regulator (1) to remove the regulator assembly from
the backplate (6) of the enclosure.
8. Install the fittings (3) to the new regulator
9. Use the included screws to attach the new air regu-
lator (1) to the included base (4).
10. Use the included screws (5) to attach the regulator
assembly to the backplate (6) of the enclosure.
11. Connect the hoses (3) to the sides of the air regula-
tor (1).
12. Attach the M12 cable (2) to the top of the air regula-
tor (1).
13. Close the enclosure.
14. Reconnect power to the controller.
F
IG
. 28 Replace the Regulator
3
5
4
2
1
6
8