background image

Eliminate the risk of  

short-circuits and electrical accidents

The world’s first instrument to offer 

no-metal-contact power measurement

Free from the risk of short-circuit accidents since no 

metal comes into contact with energized parts, the 

Clamp On Power Logger PW3365-20 can measure 

voltage, current, and power right on the cable, letting 

you safely test in locations that were dangerous or 

even impossible in the past.

CLAMP ON POWER LOGGER

Power Measuring Instruments

PW3365

28022  Madrid         Fax. 913885433          [email protected]

Septiembre, 31       Tel. 913000191           www.idm-instrumentos.es

Содержание PW3365

Страница 1: ...no metal comes into contact with energized parts the Clamp On Power Logger PW3365 20 can measure voltage current and power right on the cable letting you safely test in locations that were dangerous or even impossible in the past CLAMP ON POWER LOGGER Power Measuring Instruments PW3365 28022 Madrid Fax 913885433 idm idm instrumentos es Septiembre 31 Tel 913000191 www idm instrumentos es ...

Страница 2: ...nergized parts Measure both thick and thin cables The PW3365 20 s dedicated voltage sensor delivers the world s first no metal contact measurement Locations without energized parts Measure on the outside of cables Inside the PW9020 is an electrode a metal plate When there is a potential difference between this electrode and the measured line a minute current flows as a result By detecting this min...

Страница 3: ... 220g 7 8 oz Operating temperature and humidity 0 C to 50 C 32 F to122 F 80 RH or less no condensation Storage temperature and humidity 10 C to 60 C 14 F to 122 F 80 RH or less no condensation Dielectric strength 7 06k Vrms AC Applicable standards Safety EN61010 EMC EN61326 1 Shielded wires cannot be measured 2 For frequencies of 45 Hz to 66 Hz Effects of humidity Add the following to the combined...

Страница 4: ...t Connect the voltage sensor Connect the clamp sensors Check wire connection status Quick Set START Choose the wire type STEP1 STEP2 STEP3 STEP4 STEP5 STEP6 If you receive a FAIL result Highlight the FAIL message with the cursor and press ENTER to view information about where the connection needs to be corrected Miswiring Example Clamp Orientation The I vector s phase direction is within the deter...

Страница 5: ...display Choose one measured parameter to create a time series display as a graph Display the maximum minimum and average values at the cursor position Read values at cursor Trend Graph Display You can create a bar graph that makes it obvious whether power is being bought or sold by switching the active power demand value display from consumption to regeneration Evaluate Photovoltaic Generation Cap...

Страница 6: ...ving OFF Waveform save OFF In all cases the maximum single file size for measurement data is about 200 MB When this is exceeded a new file is created and saving continues Available Recording Time Measurement Interval Save Time 1 seconds 15 6 days 2 seconds 31 2 days 5 seconds 77 9 days 10 seconds 155 days 15 seconds 233 days Measurement Interval Save Time 30 seconds 1 year 1 minutes 1 year 2 minut...

Страница 7: ...nts Other convenient features Measure three single phase 2 wire circuits in the same system at the same time Key lock function Lock the buttons to prevent erroneous operation Control and monitor from a remote location Use a LAN cable to connect the PW3365 20 to a personal computer for real time remote monitoring and measurement display on a web browser Files recorded in the Clamp On Power Logger s...

Страница 8: ...50 100 500 A 500A range AC FLEXIBLE CURRENT SENSOR CT9667 01 02 03 500 1k 5k A 5000A range Leakage current LEAK CLAMP ON SENSOR 9675 50m 100m 500m 1 5 A LEAK CLAMP ON SENSOR 9657 10 50m 100m 500m 1 5 A Total display range Within 0 4 to 130 of the range zero is suppressed for less than 0 4 Effective measurement range Within 5 to 110 of the range OVER indicates over range warning Power ranges 200 00...

Страница 9: ... settings Sets the header and footer for each printout Printing support Any color or monochrome printing supported by the operating system Report printing Print static contents over a specific time period Output contents Standard or selected output items Available output items Trend graph summary daily report waveform Report creation method Standard print Report output settings Save load report ou...

Страница 10: ...3 8 1 oz 77W 151H 42D mm 380g 3 03 5 94 1 65 13 4 oz 99 5W 188H 42D mm 590g 3 92 7 40 1 65 20 8 oz 50 5W 58H 18 7Dmm 50g 2 28 2 28 0 74 1 8 oz 50 5W 58H 18 7Dmm 50g 2 28 2 28 0 74 1 8 oz Accuracy Amplitude 45 to 66 Hz Phase 45 Hz to 5 kHz 0 3 rdg 0 02 f s 0 3 rdg 0 02 f s 0 3 rdg 0 01 f s 1 0 rdg 0 01 f s 0 3 rdg 0 02 f s 0 3 rdg 0 02 f s Within 2 Within 1 Within 0 5 Within 1 Within 2 Within 1 Mea...

Страница 11: ...ach measurement applied to calculation 1 dgt Energy Active and reactive power measurement accuracies 1 dgt Power factor From each measurement applied to calculation 1 dgt Frequency 0 5 rdg with 90 to 520 V sine wave input Demand value Active and reactive power measurement accuracies 1 dgt Demand quantity Active and reactive power measurement accuracies 1 dgt Conditions of guaranteed accuracy After...

Страница 12: ... function Waveform display Print function Report printing BATTERY SET PW9002 Battery Case and Battery Pack Set CLAMP ON LEAK SENSOR for leakage current measurement CLAMP ON SENSOR for load current measurement CLAMP ON ADAPTER 9290 10 Primary side 1000A Secondary side 100A CLAMP ON SENSOR 9694 AC5A CLAMP ON SENSOR 9660 AC100A CLAMP ON SENSOR 9661 AC500A CLAMP ON SENSOR 9669 AC1000A AC FLEXIBLE CURR...

Отзывы: