41
Making Measurements in BPD TEST Mode
N
(
-
)
P
(
+
)
7
Release
6
5
Press
5
Press the
MEASURE
key
.
Starts a measurement.
To make a continuous measurement,
raise the
MEASURE
key.
6
Check the judgment and
displayed values.
7
Release the
MEASURE
key with the test leads connected to
the measurement object.
Ends the measurement.
•
During measurement, do not switch over to other modes.
•
The screen is locked 1 minute after the last measurement. To continue
the measurement, release the lock function. (p. 39)
• If negative voltage notification function is engaged, no measurement
starts. Verify the test lead connections once again.
•
If the solar panel is not generating power due to the shielding of the light,
continuous measurement and negative voltage notification functions will
not be activated.
• The R
BPR
value will flash if the insolation varies during measurement
(for example, due to the movement of clouds). In this case, it will not
be possible to accurately measure the bypass route resistance. Repeat
measurement under conditions of consistent insolation
Press the
MEASURE
key once per string for measurements. If the result
is FAIL, verify the test lead connections once again.
8
Measure all strings.
Repeat the above procedure from
3
to
7
.
1
2
4
5
6
7