EXHAUST (J05E)
11–97
MOUNTING THE DPR DIFFERENTIAL PRESSURE
SENSOR
1.
MOUNTING THE DPR DIFFERENTIAL PRESSURE SENSOR
(1)
Mount the DPR differential pressure sensor to the bracket with 2
nuts.
Tightening Torque:
31 N·m {316 kgf·cm, 22.9 lbf·ft}
2.
CONNECTING THE HOSE
(1)
Align the markings on the hoses, differential pressure sensor, and
muffler. Mount 2 hoses to the DPR differential pressure sensor
and differential pressure pipe with 4 clamps.
! CAUTION
•
If the DPR differential pressure sensor hose is inserted incor-
rectly, the DPR will not operate properly.
•
Use care to avoid twisting or kink of the hoses.
•
Insert the hoses to the end at which they come in contact
with the DPR differential pressure sensor body.
•
Insert the hoses to the end at which they come in contact
with the spools on the differential pressure pipes.
3.
CONNECTING THE HARNESS
(1)
Connect the connector to the DPR differential pressure sensor.
(2)
Mount the harness clamp.
DPR
DIFFERENTIAL
PRESSURE
SENSOR
SHTS021271000174
Содержание S5-LJ05E04A
Страница 4: ...INDEX ENGINE GROUP 2 2 ENGINE PTO POWER TAKE OFF INDEX_EN fm 3 ページ 2012年11月19日 月曜日 午前9時46分 ...
Страница 235: ...EMISSION CONTROL J05E 8 11 1 Closed ventilator 3 Element 2 Cap 4 Body 1 2 3 4 SHTS021270700016 ...
Страница 377: ...ENGINE MECHANICAL J05E 10 101 CRANKSHAFT COMPONENT LOCATOR EN01F02127090402028001 1 Crankshaft 1 SHTS021270900240 ...
Страница 378: ...ENGINE MECHANICAL J05E 10 102 1 Thrust bearing 2 Crankshaft bearing 1 2 SHTS021270900241 ...
Страница 550: ...COOLING J05E 12 15 RADIATOR CAP COMPONENT LOCATOR EN01F02127110402020001 1 Radiator cap 1 SHTS021271100023 ...