background image

12

English

6 Operating the laser receiver

6.1 Inserting the batteries in the laser receiver

Insert the batteries in the laser receiver.

Note

Use only batteries that have been manufactured in accordance with international standards.

6.2 Using the laser receiver to detect the laser beam

1. Press the

button on the laser receiver.

2. Hold the laser receiver with the receiving window directly in the plane of the laser beam.

3. Hold the laser receiver still while alignment is taking place and take care to ensure that the line of sight

between the laser receiver and the tool is not obstructed.

Detection of the laser beam is indicated by visual and audible signals.

The laser receiver indicates the distance to the laser beam.

6.3 Setting the units to be used

1. When switching the laser receiver on, press and hold the

button for two seconds.

The menu is then shown in the display.

2. Use the

button to toggle between metric or imperial measuring units.

3. Switch the laser receiver off by pressing the

button.

The settings will be saved.

6.4 Changing the units used by the laser receiver

1. Switch the laser on. → page 9

2. Press the

button repeatedly.

The desired accuracy (mm/cm/off) is shown alternately in the digital display.

6.5 Adjusting the volume level on the laser receiver

1. Switch the laser on. → page 9

2. Press the

button repeatedly.

The desired volume level (low/normal/high/off) is shown alternately in the digital display.

Note

The laser receiver is set to “Normal” volume when switched on.

6.6 Adjusting the signal tone on the laser receiver

1. When switching the laser receiver on, press and hold the

button for two seconds.

The menu is then shown in the display.

2. Use the

button to assign the rapid signal tone to the upper or lower detection area.

Printed: 31.07.2017 | Doc-Nr: PUB / 5260662 / 000 / 01

Содержание PR 2-HS A12

Страница 1: ...PR 2 HS A12 English Printed 31 07 2017 Doc Nr PUB 5260662 000 01 ...

Страница 2: ...Printed 31 07 2017 Doc Nr PUB 5260662 000 01 ...

Страница 3: ...ps in the text Item reference numbers are used in the overview illustration In the product overview section the numbers shown in the legend relate to these item reference numbers 1 2 On the product Laser information Laser Class 2 based on the IEC60825 1 EN60825 1 2007 standard in com pliance with CFR 21 1040 Laser Notice 50 Do not stare into beam 1 3 About this documentation Read these operating i...

Страница 4: ...y Hilti may restrict the user s authorization to operate the equipment You must check the accuracy of the tool after it has been dropped or subjected to other mechanical stresses When the tool is brought into a warm environment from very cold conditions or vice versa allow it to become acclimatized before use Make sure that the tool is mounted securely when adapters or accessories are used Keep th...

Страница 5: ...e There is a risk of explosion Do not disassemble squash or incinerate batteries and do not subject them to temperatures over 80 C 176 F This presents a risk of fire explosion or injury through contact with caustic substances Do not subject the battery to hard mechanical impacts and do not throw the battery Batteries must be kept out of reach of children Avoid ingress of moisture Ingress of moistu...

Страница 6: ...location well away from flammable materials where it can be kept under observation and allowed to cool down 3 Description 3 1 Overview of the product 3 1 1 PR 2 HS A12 rotating laser Laser beam plane of rotation Rotary head Grip Battery release button Li ion battery Battery charge status display Control panel Base plate with 5 8 thread Printed 31 07 2017 Doc Nr PUB 5260662 000 01 ...

Страница 7: ...g Button and LED Shock warning deactiva tion Button and LED Manual inclined plane mode Battery charge state LEDs 3 1 3 PRA 20 laser receiver control panel On off button Volume button Units key Receiving area Marking notch Display Printed 31 07 2017 Doc Nr PUB 5260662 000 01 ...

Страница 8: ... Auto leveling is active within the 5 range relative to the horizontal plane and can be deactivated by pressing the button The tool can be set up directly on the ground or floor on a tripod or with the aid of suitable mounting brackets Inclination angle Alternatively in inclined plane mode the slope adapter can be adjusted manually to achieve slopes of up to 60 Auto leveling is not active Automati...

Страница 9: ...s light Charge status 25 to 50 1 LED lights Charge status 10 to 25 1 LED blinks Charge status 10 Note When the tool is in operation the battery charge status is indicated in the display on the tool When not in operation battery charge state can be indicated by lightly pressing the release button During charging charge state is indicated by the LEDs on the battery please refer to the operating inst...

Страница 10: ...me without detection before automatic power off 15 min Drop test height in the PRA 83 laser receiver holder under standard ambient conditions in accordance with MIL STD 810G 6 ft 10 in 2 m Operating temperature 4 122 20 50 Storage temperature 13 140 25 60 Weight including batteries 0 55 lb 0 25 kg Protection class in accordance with IEC 60529 IP66 5 Operating the rotating laser 5 1 Handling the la...

Страница 11: ...efore inserting the battery CAUTION Risk of injury If the battery is not fitted correctly it may drop out and fall Check that the battery is securely seated in the tool so that it cannot drop out and fall thereby presenting a hazard to other persons 1 Push the battery in until it engages securely The laser is ready to switch on 2 Press the release button and hold it in this position 3 Pull the bat...

Страница 12: ...osition yourself behind the laser tool facing the control panel 6 With the aid of the target notch on the head of the laser tool adjust the tool with the slope adapter until it is parallel to the inclined plane 7 Press the button on the laser tool The inclined plane mode LED then lights on the control panel of the laser tool The laser tool then begins automatic self leveling The laser switches on ...

Страница 13: ...n doing so ensure that the height of the tool does not change 5 Fig b Use the laser receiver to catch the laser beam and mark a second point point 2 on the wall 6 Fig c and d Repeat the two previous steps twice and use the laser receiver to catch the beam and mark points 3 and 4 on the wall Note If the procedure has been carried out accurately the vertical distance between the two marked points 1 ...

Страница 14: ... on press and hold the button for two seconds The menu is then shown in the display 2 Use the button to toggle between metric or imperial measuring units 3 Switch the laser receiver off by pressing the button The settings will be saved 6 4 Changing the units used by the laser receiver 1 Switch the laser on page 9 2 Press the button repeatedly The desired accuracy mm cm off is shown alternately in ...

Страница 15: ...o severe injury and burns Always remove the battery before carrying out care and maintenance tasks Care and maintenance of the tool Carefully remove any dirt that may be adhering to the tool Use only a slightly damp cloth to clean the casing Do not use cleaning agents containing silicone as these may attack the plastic parts Care of the lithium ion batteries Keep the battery free from oil and grea...

Страница 16: ...of his her obligation to check the product before and during use 7 3 Checking accuracy In order to ensure compliance with the technical specifications the tool should be checked regularly at least before each major relevant measuring task After falling from considerable height the tool should be checked for correct accurate operation When the following conditions are fulfilled it can be assumed th...

Страница 17: ... present a health hazard Batteries may explode if damaged or exposed to very high temperatures causing poisoning burns acid burns or environmental pollution Careless disposal may permit unauthorized and improper use of the equipment This may result in serious personal injury injury to third parties and pollution of the environment Dispose of defective batteries right away Keep them out of reach of...

Страница 18: ...16 English Note Changes or modifications not expressly approved by Hilti may restrict the user s authorization to operate the equipment Printed 31 07 2017 Doc Nr PUB 5260662 000 01 ...

Страница 19: ...Printed 31 07 2017 Doc Nr PUB 5260662 000 01 ...

Страница 20: ...Hilti registered trademark of Hilti Corp Schaan 20170720 Printed 31 07 2017 Doc Nr PUB 5260662 000 01 ...

Отзывы: