***** Nur für internen Gebrauch ***** 07.02.2020 / 13:17:39 - H2\DOK-Sprachpaket\System\PM_30-G1\DEU\PM30-MG_POS1
*2243556*
2243556
English
15
Operating status indicator
Laser beams and the switch positions “Off”, “On
locked” and “On unlocked”
Power source
Hilti
B 12 Li-ion battery
Battery life (all lines on)
Hilti
B12 Li-ion battery 2600 mAh, tempe24
°C (+72 °F): 8 h (typical)
Battery life (horizontal or vertical lines on)
Hilti
B 12 Li-ion battery, 2600 mAh, temperature
+24 °C (+72 °F): 12 h (typical)
Operating temperature
−10 ℃ … 40 ℃
(14 ℉ … 104 ℉)
Storage temperature
−25 ℃ … 63 ℃
(−13 ℉ … 145 ℉)
Dust and water spray protection (except bat-
tery compartment)
IP 54
Tripod thread
BSW 5/8" | UNC 1/4"
Beam divergence
0.05 mrad * 360°
Average output power (max.)
< 0.95 mW
Weight including battery
1.28 kg
(2.82 lb)
5
Operation
CAUTION
Risk of injury!
Do not direct the laser beam toward persons.
▶
Never look directly into the source of the laser beam. In the event of direct eye contact, close your eyes
and move your head out of the path of the laser beam.
5.1
Charging the battery
1. Before charging the battery, read the operating instructions for the charger.
2. Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3. Use an approved charger to charge the battery.
5.2
Inserting the battery
CAUTION
Risk of injury by short circuit or falling battery!
▶
Before inserting the battery, make sure that the contacts on the battery and the contacts on the product
are free of foreign matter.
▶
Make sure that the battery always engages correctly.
1. Charge the battery fully before using it for the first time.
2. Push the battery into the battery holder until it engages with an audible click.
3. Check that the battery is seated securely.
5.3
Removing the battery
1. Press the battery release button.
2. Remove the battery from the device.
5.4
Matching two points over distance by fine adjustment
1. Position the device with the lower plumbing beam centered on the reference cross on the ground.
2. Turn the knob for fine adjustment until the vertical laser beam is aligned with the second, remote control
point.
Содержание PM 30-MG
Страница 2: ... Nur für internen Gebrauch 07 02 2020 13 17 39 H2 DOK Sprachpaket System PM_30 G1 DEU PM30 MG_POS1 1 ...
Страница 337: ... Nur für internen Gebrauch 07 02 2020 13 17 39 H2 DOK Sprachpaket System PM_30 G1 DEU PM30 MG_POS1 ...
Страница 338: ... Nur für internen Gebrauch 07 02 2020 13 17 39 H2 DOK Sprachpaket System PM_30 G1 DEU PM30 MG_POS1 ...
Страница 339: ... Nur für internen Gebrauch 07 02 2020 13 17 39 H2 DOK Sprachpaket System PM_30 G1 DEU PM30 MG_POS1 ...
Страница 340: ...Hilti registered trademark of Hilti Corp Schaan Pos 1 20200207 2243556 2243556 ...