26
Malfunction
Possible cause
Action to be taken
Fastener driving failure rate is
too high.
The fastener guide is not held per-
pendicular to the working surface.
▶
Press the nosepiece against the
working surface while keeping
the tool perpendicular to the
surface.
Wrong type of fastener used.
▶
Use a suitable type of fastener.
The supporting material is too
hard.
▶
Consider using a DX fastening
tool.
No fastener is driven.
The nail pusher was not moved
forward.
▶
Release the nail pusher and
guide it forward as far as it will
go.
Insufficient nails in the magazine (2
nails or fewer).
▶
Load the magazine. → page 20
Nail transport malfunction.
▶
Use a different nail strip.
▶
Clean the magazine.
Gas can is empty.
▶
Check the status of the gas can.
→ page 22
LED 1 lights red
▶
Check the status of the gas can.
→ page 22
Air in the gas lines
▶
Press the setting tool three
times in position without pulling
the trigger.
Foreign object in the area of the
fastener guide
▶
Remove foreign objects and
nails from the area around the
fastener guide. → page 24
The fastening tool is too hot.
▶
Allow the fastening tool to cool
down.
Electronic fault.
▶
Remove the gas can and then
reinsert it. If the problem
persists, use a new gas can.
The fastening tool is hot and
doesn’t work even after a
break.
The fastener driving rate was well
above 1,200 fastenings per hour.
▶
Allow the fastening tool to cool
down.
No fastener is driven (or
driven only intermittently).
Ambient conditions are outside the
permissible range.
▶
Make sure that the permissible
ranges, in accordance with the
technical data, are observed.
The gas can temperature is outside
the permissible range.
▶
Make sure that the permissible
ranges, in accordance with the
technical data, are observed.
Gas bubbles have formed in the
gas regulating system.
▶
Remove the gas can and then
reinsert it.
The tool was not lifted completely
away from the surface after driving
a fastener.
▶
Lift the fastening tool completely
away from the working surface
after driving a fastener.
A fastener cannot be
removed from the fastener
guide.
A fastener has jammed in the fas-
tener guide.
▶
Release the jammed fastener.
13 Disposal
Most of the materials from which
Hilti
tools and appliances are manufactured can be recycled. The
materials must be correctly separated before they can be recycled. In many countries, your old tools,
machines or appliances can be returned to
Hilti
for recycling. Ask
Hilti
Service or your Hilti representative
for further information.
Printed: 29.01.2016 | Doc-Nr: PUB / 5261568 / 000 / 00