Fault
Possible cause
Remedy
The piston gets stuck in the
base material / fastener is
driven too deeply.
The fastener is too short.
Use a longer fastener.
The fastener has no washer.
Use a fastener with washer for applic-
ations on wood.
Driving power is too high.
Use a less powerful cartridge.
The fastener is not driven
deeply enough.
The fastener is too long.
Use a shorter fastener.
NOTE
Observe the min. fastener driving
depth requirements. Obtain a copy
of the Fastening Technology Manual
from your local Hilti Center.
Driving power is too low.
Use a more powerful cartridge.
The nail bends.
Hard surface or hard and/or large ag-
gregates in the concrete.
Use a more powerful cartridge.
Use the DX-Kwik method (predrilling).
A rebar is located just below the con-
crete surface.
Use a shorter nail.
Use a nail with a higher application
limit.
Use the DX-Kwik method (predrilling).
Drive the fastener at a different posi-
tion.
Concrete spalling.
Hard/old concrete.
Use a shorter nail.
Hard surface or hard and/or large ag-
gregates in the concrete.
Use a more powerful cartridge.
Use the DX-Kwik method (predrilling).