background image

Diagnosis with LEDs

29/63

5.5

OpenModbusTCP

For the 

OpenModbusTCP

 protocol, the communication LEDs 

RUN

 and

ERR

 as well as the Ethernet LEDs 

LINK

 and 

ACT

 can assume the states

described below. This description is valid from stack version V0.9.

Communication status OpenModbusTCP

LED

Color

State

Description

RUN

Position in the device
overview: 

(10)

Duo LED red/green

 (green)

On

Connected:

 OMB task has communication. At least one TCP

connection is established.

 (green)

Flashing 
(1 Hz)

Ready, not configured yet:

 OMB task is ready and not yet

configured.

 (green)

Flashing
(5 Hz)

Waiting for Communication:

 OMB task is configured.

 (off)

Off

Not Ready:

 OMB task is not ready.

ERR

Position in the device
overview: 

(7)

Duo LED red/green

 (off)

Off

No communication error

 (red)

Flashing 
(2 Hz, 25% on)

System error

 (red)

On

Communication error active

Table 26: Communication status OpenModbusTCP

LED state

Definition

Flashing 
(1 Hz)

The LED turns on and off with a frequency of 
1 Hz: "On" for 500 ms, followed by "Off" for 500 ms.

Flashing
(5 Hz)

The LED turns on and off with a frequency of 
5 Hz: “On” for 100 ms, followed by “Off” for 100 ms.

Flashing 
(2 Hz, 
25% on)

The LED turns on and off with a frequency of 
2 Hz: “On” for 125 ms, followed by “Off” for 375 ms.

Table 27: Definition LED states communication status

Ethernet status OpenModbusTCP

LED

Color

State

Description

LINK

Ch0: 

(11)

 , Ch1: 

(8)

LED green

 (green)

On

The device is linked to the Ethernet.

 (off)

Off

The device has no link to the Ethernet.

ACT

Ch0: 

(9)

 , Ch1: 

(6)

LED yellow

(yellow)

Flickering (load
dependent)

The device sends/receives Ethernet frames.

 (off)

Off

The device does not send/receive Ethernet frames.

Table 28: Ethernet status OpenModbusTCP

LED state

Definition

Flickering 
(load 
dependent)

The LED turns on and off with a frequency of approximately 10 Hz to
indicate high Ethernet activity: "On" for approximately 50 ms, followed by
"Off" for 50 ms. The LED turns on and off in irregular intervals to indicate low
Ethernet activity.

Table 29: Definition LED states Ethernet status

CIFX M223090AE-RE\F | Hardware description and installation
DOC190704UM06EN | Revision 6 | English | 2022-02 | Released | Public

© Hilscher 2019 - 2022

Содержание CIFX M223090AE-RE/F

Страница 1: ...anual CIFX M223090AE RE F PC card PCI Express M 2 2230 A E Real Time Ethernet Slave Hilscher Gesellschaft f r Systemautomation mbH www hilscher com DOC190704UM06EN Revision 6 English 2022 02 Released...

Страница 2: ...evices 12 3 5 4 Power drop during write and delete accesses in the file system 13 3 5 5 Exceeding the maximum number of permitted write and delete accesses 13 3 6 Information and data security 13 3 7...

Страница 3: ...us 38 7 3 AIFX V2 RE 39 7 4 Communication protocols 40 7 4 1 EtherCAT Slave 40 7 4 2 EtherNet IP Adapter 42 7 4 3 Open Modbus TCP 43 7 4 4 PROFINET IO Device 44 8 Dimensions 46 8 1 Tolerances of PCB d...

Страница 4: ...Connector Ethernet X1 on AIFX V2 RE added Section EtherNet IP Adapter V3 5 page 27 updated Device Explorer details updated with configuration download Section Dimensions AIFX V2 RE page 48 Thickness...

Страница 5: ...22x30 mm Keys A and E PCI Express slot 3 3 V for M 2 type 2230 D3 Dual Key A E Socket 1 Connectivity Table 2 PC card CIFX M223090AE RE F Product family Card format and size netX Key Network Cable CIF...

Страница 6: ...ground contact for mounting the PC card 3 Cable connector Ethernet X801 20 pin 4 System LED yellow green 5 Matrix label 6 PCI Express M 2 bus pin 1 to pin 7 7 PCI Express M 2 bus pin 8 to pin 15 key...

Страница 7: ...channel 1 CH1 9 Ethernet LED yellow channel 0 CH0 10 Communication status LED COM0 red green 11 Ethernet LED green channel 0 CH0 Table 5 Legend on the detached network interface AIFX V2 RE Important...

Страница 8: ...Part no Hardware revision CIFX M223090AE RE F Basic card CIFX M223090AE and AIFX V2 RE 1443 101 CIFX M223090AE Communication Interface M 2 2230 Key A E basic card 1443 100 4 AIFX V2 RE Detached netwo...

Страница 9: ...vice overview The device label consists of a matrix code and the information contained therein in plain text The 2D code Data Matrix Code contains the following information Part number 1234 567 Hardwa...

Страница 10: ...hernet system can be realized Information on the permissible Real Time Ethernet systems can be found in the section Revision or version status of hardware and software page 8 3 3 Personnel qualificati...

Страница 11: ...e power plug of the PC or connection device before opening the housing Make sure that the power supply is off at the PC or connection device Only then open the housing and install or remove the PC car...

Страница 12: ...the specified signal voltage can cause serious damage to the PC card 3 5 3 Electrostatic sensitive devices This equipment is sensitive to electrostatic discharge which cause internal damage and affec...

Страница 13: ...uration or changing the name of station leads to the maximum number of permitted write delete accesses being exceeded and to device damage For example if the configuration is changed once an hour the...

Страница 14: ...First disconnect the power plug of the PC or connection device before you open the housing Make sure that the power supply is off at the PC or connection device Personal injury device damage due to h...

Страница 15: ...t the I O signal pins on the PCIe bus of the PC card Host system For communication via PCI Express the host system may only use the standard mode with a length of 5 bits for identification tag field l...

Страница 16: ...or mounting the AIFX must be provided on the housing of the PC or connection device Panel cut outs The layout for the panel cut outs must be sufficiently dimensioned for Two Ethernet RJ45 sockets for...

Страница 17: ...ttings in the used Master must match the settings in the Slave Software installation cifX Device Driver as driver for the host interface latest version of the driver Device Explorer as software for do...

Страница 18: ...he hardware installation Open the housing of the PC or connection device Insert the basic card into the PCI Express M 2 slot and mount the basic card Mount the detached network interface to the front...

Страница 19: ...rquing of the mounting screw Do not over torque the screw used to mount the basic card to the board to prevent damage to the printed circuit board 3 Installation Open the housing of the PC or connecti...

Страница 20: ...hard disk of your PC If necessary transfer the configuration to the PC You create the configuration using a suitable configuration software Use Device Explorer to load the firmware and configuration...

Страница 21: ...ard cifX is in the in operation state The salve device is in the state of cyclic communication with the connected master device The communication between the master device and the salve device runs wi...

Страница 22: ...basic card Therefore pull the cable out of the cable connector Ethernet X801 on the basic card as well as out of the cable connector Ethernet X1 on the AIFX V2 RE Loosen the screw that secures the ba...

Страница 23: ...stems duo LEDs and Ethernet LEDs Ethern et Ch0 Green L A IN LINK LINK L A LINK Yellow ACT ACT RX TX Ethern et Ch1 Green L A OUT LINK LINK L A LINK Yellow ACT ACT RX TX Category LED Name Category LED N...

Страница 24: ...is being installed gray Off No supply voltage No supply voltage for the device or hardware defect During a firmware reset Table 16 States of the SYS LED LED state Definition Blinking The LED turns on...

Страница 25: ...e commanded by master is impossible due to register or object settings red Single flash Local error Slave device application has changed the EtherCAT state autonomously Possible reason 1 A host watchd...

Страница 26: ...Ethernet Ch0 9 Ch1 6 LED yellow off Off This LED is not used Table 20 Ethernet status EtherCAT Slave LED state Definition Flickering load dependent The LED turns on and off with a frequency of approx...

Страница 27: ...figuration can be considered a major recoverable fault red On Major unrecoverable fault The device has detected a major unrecoverable fault off Off No power The device is powered off NS Network status...

Страница 28: ...LINK Ch0 11 Ch1 8 LED green green On The device is linked to the Ethernet off Off The device has no link to the Ethernet ACT Ch0 9 Ch1 6 LED yellow yellow Flickering load dependent The device sends r...

Страница 29: ...ms followed by Off for 500 ms Flashing 5 Hz The LED turns on and off with a frequency of 5 Hz On for 100 ms followed by Off for 100 ms Flashing 2 Hz 25 on The LED turns on and off with a frequency of...

Страница 30: ...or 3 seconds with a frequency of 1 Hz On for 500 ms followed by Off for 500 ms Flashing 2 Hz The LED turns on and off with a frequency of 2 Hz On for 250 ms followed by Off for 250 ms Table 31 Definit...

Страница 31: ...itive channel 2 TX Transmit data negative channel 3 RX Receive data positive channel 4 Term 1 Bridged and terminated to PE via RC link 5 Term 1 6 RX Received data negative channel 7 Term 2 Bridged and...

Страница 32: ...r the respective communication systems The following table shows the usability of hubs and switches for each communication system Communication system Hub Switch EtherCAT Forbidden Only permitted betw...

Страница 33: ...LINK ACT0 yellow green Output 9 RSTOUT Reset out Output 10 MLED1 COM1 RE LED COM1 red green Output 11 CH0_TXP Channel 0 TX Output 12 CH0_TXN Channel 0 TX Output 13 CH0_RXP Channel 0 TR Input 14 CH0_RX...

Страница 34: ...COM1 LED COM1 red green Input 11 CH0_TXP Channel 0 TX Input 12 CH0_TXN Channel 0 TX Input 13 CH0_RXP Channel 0 RX Output 14 CH0_RXN Channel 0 RX Output 15 CH1_TXP Channel 1 TX Input 16 CH1_TXN Channe...

Страница 35: ...PCI Express CEM Specification Output 44 NC not used 45 GND Return current path Power 46 NC not used 47 REFCLKP PCIe Reference Clock signals 100 MHz defined by the PCI Express CEM Specification Input 4...

Страница 36: ...NC not used 72 3 3V 3 3V supply Power 73 NC not used 74 3 3V 3 3V supply Power 75 GND Return current path Power Table 39 Pin assignment PCI Express M 2 bus X201 CIFX M223090AE CIFX M223090AE RE F Hard...

Страница 37: ...loaded Interface type 100BASE TX 10BASE T depending on firmware loaded Half duplex full duplex depending on the firmware loaded supported at 100 MBit s Auto negotiation depending on the firmware load...

Страница 38: ...ivity EMC Compliance CE sign Yes UKCA sign Yes Emission DIN EN 61000 6 3 BS EN 61000 6 3 Immunity DIN EN 61000 6 2 BS EN 61000 6 2 Documentation to prove the restriction of hazardous substances EN 505...

Страница 39: ...Ethernet activity status and other status LED green Power supply Connector Cable connector Ethernet X1 Environmental conditions Operating temperature range 20 C 70 C 20 C 60 C Air flow during measurem...

Страница 40: ...nchronized to the SM2 3 Event Synchronous with SYNC Event The application of the slave is synchronized to the SYNC0 or SYNC1 Event Supported features PDI watchdog EtherCAT mailbox handling EtherCAT st...

Страница 41: ...nal generation No Single Shot Mode support No Acknowledge Mode support Restricted DC Control Functionality No adjustment of Register Speed Counter Start 0x0930 0x931 No showing of Register Speed Count...

Страница 42: ...ct 2 0x02 Assembly object 4 0x04 Connection Manager 6 0x06 DLR object 71 0x47 QoS object 72 0x48 TCP IP object 245 0xF5 Ethernet Link object 246 0xF6 Maximum number of user specific objects 20 Support...

Страница 43: ...d via the packet API but not with the command table Protocol mode Message mode Client Client using the command table in the configuration software The data is stored in the I O process data image Clie...

Страница 44: ...ured via Number of available Diagnosis buffers in tag list Up to 256 application diagnosis records of type Channel or Extended Channel Diagnosis in general and may be smaller number for specific firmw...

Страница 45: ...igured or used by an AR in subslot 0 The stack does not support usage of PDEV submodules InterfaceSubmodule or PortSubmodule outside of slot 0 In addition the InterfaceSubmodule is only supported in s...

Страница 46: ...L Length dimension of the PCB in mm mm 0 2 mm The depth T of the PCB depends on the highest component used or the PCB thickness plus the descenders The thickness of the PCB is 0 8 mm 10 Note The dime...

Страница 47: ...ent height on the upper side of the basic card CIFX M223090AE does not comply with the standard specifications For more information see section System Requirements page 15 CIFX M223090AE RE F Hardware...

Страница 48: ...48 63 8 3 Dimensions AIFX V2 RE Figure 9 Dimensions AIFX V2 RE revision 2 CIFX M223090AE RE F Hardware description and installation DOC190704UM06EN Revision 6 English 2022 02 Released Public Hilscher...

Страница 49: ...ch case the user will be required to correct the interference at his own expense 9 2 References PCI Express M 2 specification PCI SIG Special Interest Group PCI Express M 2 Specification Revision 1 1...

Страница 50: ...Normung e v and VDE Verband der Elektrotechnik Elektronik Informationstechnik e V German standard Equipment for audio video information and communication technology Part 1 Safety requirements IEC 623...

Страница 51: ...arge Reference to further information Principle Disconnect the power plug Table 47 Signs Signal words Signal word Description Indicates a hazardous situation which if not avoided will result in death...

Страница 52: ...efore we cannot assume any guarantee or legal responsibility for erroneous information or liability of any kind You are hereby made aware that descriptions found in the user s manual the accompanying...

Страница 53: ...e and or software in connection with Flight control systems in aviation and aerospace Nuclear fission processes in nuclear power plants Medical devices used for life support and Vehicle control system...

Страница 54: ...due to violations against our operating regulations or against rules of good electrical engineering practice or if our request to return the defective object is not promptly complied with Costs of su...

Страница 55: ...pecified in this agreement The customer must not use this confidential information to his own advantage or for his own purposes or rather to the advantage or for the purpose of a third party nor must...

Страница 56: ...OFINET is a registered trademark of PROFIBUS PROFINET International PI Karlsruhe PCI Express and PCIe are trademarks or registered trademarks of the Peripheral Component Interconnect Special Interest...

Страница 57: ...Ethernet AIFX V2 RE 20 Figure 5 Connecting cable to basic card example CIFX M223090AE 20 Figure 6 Ethernet pin assignment at the RJ45 socket 31 Figure 7 Cable connector Ethernet X1 1x20 pins AIFX V2 R...

Страница 58: ...ve 26 Table 21 Definition LED states Ethernet status 26 Table 22 Communication status EtherNet IP Adapter 27 Table 23 Definition LED states communication status 28 Table 24 Ethernet status EtherNet IP...

Страница 59: ...9 Table 43 Technical data EtherCAT Slave 40 Table 44 Technical data EtherNet IP Adapter 42 Table 45 Technical data Open Modbus TCP 43 Table 46 Technical data PROFINET IO Device 44 Table 47 Signs 51 Ta...

Страница 60: ...ion Technology communication system for Industrial Ethernet designed and developed by Beckhoff Automation GmbH Verl Germany EtherCAT Slave Device which is configured by the EtherCAT master receives da...

Страница 61: ...ed system architecture for communication and maximum data transfer Open Modbus TCP Communication system for Industrial Ethernet designed and developed by Schneider Automation and maintained by the Mod...

Страница 62: ...k with each other capable to analyze the network traffic in order to decide on its own and shows transparent behaviour to connected communication partners SYNC Sychronisation Cycle of the Master CIFX...

Страница 63: ...25007068 E mail info hilscher it Support Phone 39 02 25007068 E mail it support hilscher com Japan Hilscher Japan KK Tokyo 160 0022 Phone 81 0 3 5362 0521 E mail info hilscher jp Support Phone 81 0 3...

Отзывы: