Successively with compressed
Air
,
clean the air conveyor compartment
of the suction motor.
7.4.5
Recovery Tank
Check
(to perform every
50h
)
The recovery tank has to be clean and
has not to have cracks or, in general,
any kind of damage.
The Lid housing
has to be even and flat to allow the
gasket to adhere perfectly to the tank
to avoid any air infiltration.
The hose
fittings have to be in optimum condition
in order to avoid any dirty water leakage
or any pressure drop during the job.
7.4.6
Vacuum Motor
Check
(to perform every
150h
)
Access the Check/Monitor Menu, and
select the parameter
I Vac
, pressing the
button 2.
The vacuum motor with hose discon-
nected from the squeegee has to absorb
less than
2,8 Amps
.
The motor should rotate evenly and
smoothly and doesn’t have to produce
unusual noises.
The motor contacts
have to be clean, they have not to show
signs of wear or heating in general.
The motor wires
insulation has to be
intact in all its parts and does not show
signs of cracks. The single cable have to
be flexible.
46