3.
Check the voltage in
AC
on the connector
Y
Yellow & Red
(with
running machine)
V
≥
25
YES
⇒
Replace the
motor
NO
⇒
Point 4
4.
Check the voltage
on the connector
X
Red & Black
(with
running machine)
V
≥
33
YES
⇒
Replace the
motor card
NO
⇒
Point 5
5.
Check the voltage
on the connector
W
Black & Yellow
(with
running machine)
V
≥
0
YES
⇒
Point 6
NO
⇒
Replace the
motor
6.
Check the voltage
on the connector
W
Black & White
(with
running machine)
V
≥
0
YES
⇒
Point 7
NO
⇒
Replace the
motor
7.
Check the voltage
on the connector
W
Black & Green
(with
running machine)
V
≥
0
YES
⇒
Replace the
motor card
NO
⇒
Replace the
motor
8.
Check the voltage
on the connector
J1
Red & Black
(with
running machine)
V
≥
33
YES
⇒
Replace the
cables
NO
⇒
Replace the
main card