background image

 

VIEW ZONE STATUS 

Step 1  Press   

r

    

  . The LCD Screen will display the zone status. 

Step 2  Use the up and down scroll keys to browse through the descriptions. The 

LCD Screen will display the list of all zones in sequential order by zone 
number. 

Step 3  Press [#] to exit this function.

 

 
 
SETTING THE KEYPAD TONE 

Step 1  Press   

r

     

0

   .  Keypad is now in the “Adjust Tone” mode. 

Step 2  Press the  

   up scroll key located 

on the right side of the display to 
adjust the keypad sounder to higher 
tones.

 

Step 3  Press the 

  down scroll key to adjust the keypad sounder to lower tones.

 

Step 4  When the desired tone is reached, press   

   to set this tone and exit from 

the “Adjust Tone” mode. 

 
 

VIEW ALARM MEMORY 

Step 1  Press   

r

      

3

    to display the zone(s) on the keypad that created the last 

alarm.

 

Raise tone

                 

º

 

Lower tone

         º

 

A

l

arm Memory 1 

ZONE 1 

Step 2  The LCD Screen will display the 

zone description for those zones. 

Step 3  Press [

#

] to exit the alarm memory.

 

 
 
TEST FUNCTION (Optional, if programmed) 

If programmed, this function will perform a battery test, communicator test, and/or a 
siren test. No alarms will be sent, and no reports will be sent unless a 
communicator test is performed, in which case a test signal will be sent. 

Step 1  Press   

r

     

4  

   

  . The test will be performed as programmed. 

Step 2  If the siren test is performed, enter a user code to silence the siren. 
 
 

Hills LCD Keypad 

11 

Содержание HILLS series

Страница 1: ...HILLS Series LCD Code Pad User Manual ...

Страница 2: ...RS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system YOU SHOULD BE AWARE OF THE FOLLOWING FACTS WHEN PREPARING A SAFETY SECURITY PLAN FOR YOUR HOME BUSINESS 1 Your security system is an electronic device and like any electronic device is subject ...

Страница 3: ...SETTING THE KEYPAD TONE 11 VIEW ALARM MEMORY 11 TEST FUNCTION OPTIONAL IF PROGRAMMED 11 DISPLAY TEST FUNCTION 12 LIGHT CONTROL FOR X 10 DEVICES OPTIONAL IF PROGRAMMED 12 CHANGE LANGUAGES 12 CHANGING USER CODES 13 ASSIGNING USER CODE AUTHORITY LEVELS 13 RESET FUNCTION 14 READING THE EVENT LOG 15 ADJUSTING THE VIEW BRIGHTNESS OF THE LCD 15 SETTING THE SYSTEM CLOCK 16 USING THE DOOR CHIME FEATURE 16 ...

Страница 4: ...he warranty period return it to place of purchase Hills Industries assumes no liability for consequential or indirect damage and accepts no responsibility for repairing damage to the product caused by misuse careless handling or where repairs have been made by others No other guarantee written or verbal is authorized by or on behalf of Hills Industries Hills LCD Keypad 2 ...

Страница 5: ...dy to be force armed will flash the ready light NOTE Those zones that are not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 digit code that has been programmed by the installer to operate a device Group Bypass An option that allows the user to bypass multiple zones with a single operation Instant Delay An option that allows an instant alarm condition for ...

Страница 6: ... will flash during the last 10 seconds of the exit delay as a warning that the time is running out The user may want to disarm the system if the exit light is flashing in order to prevent an alarm The user may then re arm the system and exit before the delay expires Fire Light A steady fire light means a fire zone has been faulted A rapidly flashing fire light means that a fire zone is in a troubl...

Страница 7: ...ur 4 or 6 digit user code to arm the system The armed and exit lights will illuminate You may now leave the building System Ready Type Code to Arm System Not Ready For help press º System Armed All Zones Secure IMPORTANT The exit light will flash rapidly for the last 10 seconds of the exit delay as a warning to the user that the exit time is about to expire The user may wish to disarm and rearm th...

Страница 8: ...xit door If Auto Bypass is enabled omit Step 3 When Auto Instant is enabled if you do not leave through a designated entry exit door the display will read Instant indicating that the entry exit doors no longer have an entry delay If Auto Instant is enabled omit Step 4 Step 3 Press the STAY key The stay light will illuminate indicating that all interior zones are bypassed All interior devices will ...

Страница 9: ...g the EXIT key will start the Exit delay enabling you to leave the building IMPORTANT An alarm will be created if the Instant message is ON at this time and you re enter the building You may re initiate an entry exit delay by pressing the STAY key again The Instant message will disappear DISARMING YOUR SYSTEM When you enter the protected area through one of the designated Entry Exit doors the keyp...

Страница 10: ...st be done while the system is in the disarmed state If the zone is not known refer to Procedure 2 Procedure 1 If you know the number of the zone to bypass use the following Step 1 Press the BYPASS key Step 2 When the LCD prompts for a code optional if programmed enter your user code Step 3 The bypass light flashes Step 4 Enter the zone you wish to bypass Example Press 6 for zone 6 or 1 1 2 for zo...

Страница 11: ... will be bypassed Press the BYPASS key again to exit group bypassing UNBYPASSING To manually unbypass zones perform the bypassing procedure on a zone that is already bypassed NOTE All zones will automatically be unbypassed each time the system is disarmed EMERGENCY ACTIVATION KEYS NOTE You must press and hold these keys for 2 seconds to activate these functions Your system may not be programmed fo...

Страница 12: ...r security system will respond to the Panic Hold Up activation FUNCTION MENU The functions listed below are found in the Function Menu Step 1 Press r The display will now begin scrolling though a list of functions and the corresponding numbers associated with those functions Step 2 Press the number listed on the display in order to access that particular function Hint If you already know the funct...

Страница 13: ... desired tone is reached press to set this tone and exit from the Adjust Tone mode VIEW ALARM MEMORY Step 1 Press r 3 to display the zone s on the keypad that created the last alarm Raise tone º Lower tone º Alarm Memory 1 ZONE 1 Step 2 The LCD Screen will display the zone description for those zones Step 3 Press to exit the alarm memory TEST FUNCTION Optional if programmed If programmed this func...

Страница 14: ... want to control The LCD screen will show the light number on the left On the right side of the display it will prompt you to turn the light X 10 device On or Off Step 3 Press the to turn the X 10 device On or press the to turn the X 10 device Off Step 4 The LCD screen will again prompt you to Select Light Number 0 9 Step 5 Repeat Steps 2 and 3 until complete Step 6 Press to exit from the X 10 men...

Страница 15: ...up and down scroll keys to select the digit to change and enter the correct number If it rejects the code because of duplication or such the sounder will beep 3 times Step 5 If another user code needs to be programmed return to step 3 and enter the user code Step 6 To exit Code Programming press while the screen is prompting for a new user ASSIGNING USER CODE AUTHORITY LEVELS Assign authority leve...

Страница 16: ...that partition with a hyphen indicating access has been removed If you wish to re establish user access to the partition press the partition number again Step 5 Press r to save the data The LCD will then prompt you for the next user code Step 6 If another user code needs to be programmed return to Step 3 If not press to exit this feature without saving the data RESET FUNCTION This function is used...

Страница 17: ...own in and À indicates an 24 hour format event not reported This screen shows an opening of Partition 3 on September 25th at 5 27 p m by user 75 The r shows that this event is not programmed to be reported to the central monitoring station Refer to Appendix A on page 23 for a list of possible log messages ADJUSTING THE VIEW BRIGHTNESS OF THE LCD Step 1 Enter r 9 1 The LCD Screen will prompt for a ...

Страница 18: ...r key to move to the minutes day of week date month and year Step 5 Repeat Steps 3 and 4 until the entire time and date are set USING THE DOOR CHIME FEATURE The door chime is turned on or off by pressing the CHIME key If the chime is on the chime light will be illuminated If the chime is off the chime light will be off Each press of the CHIME key will toggle the chime feature on off and produce a ...

Страница 19: ...ll illuminate if ALL partitions are Ready The ready light will flash if all areas are Ready or Force armable FIRE will illuminate if ANY one area has a Fire condition The fire light will flash if ANY area has a Fire Trouble condition POWER will illuminate if the primary power is connected to the NX 8 control panel It will flash if the system has a low standby battery condition STAY will illuminate...

Страница 20: ...arm disarm multiple partitions enter a code that has arm disarm authority for ALL of the partitions to be armed disarmed The following display will appear on the LCD screen The numbers on the top line represent the disarmed areas to which this code has access The numbers on the bottom line represent the areas that are armed Refer to the following table for possible conditions Ready 12345678 Armed ...

Страница 21: ...idual area press r Area number To operate an individual area enter the number of the partition you wish to operate The LCD keypad will now operate as a single area keypad All keys and functions entered will affect this individual partition only The lights and display represent the status of that partition only The word System will be replaced with the word Area The following is an example of this ...

Страница 22: ...eps to indicate telephone line fault if selected Beeps during an exit delay beeps rapidly for the last 10 seconds of an exit delay and beeps 1 second at the end of the exit delay Pulses when one or more of the following conditions are detected Zone or Box Tamper Low Battery AC Power Fail or Expander trouble Beeps 3 times every minute indicating a low battery or missing transmitter is detected if w...

Страница 23: ...tempted to communicate a message to the Central Station but was unsuccessful Control Ground fault A short to ground has been detected on a control circuit Control Loss of time Your system has lost total power and needs the clock reset Control Low Battery The standby battery is low Control Over current A short circuit of a control s power supply has occurred Control Phone trouble The phone line con...

Страница 24: ...he expander Expansion RF Jammed A radio receiver is being jammed Not applicable to all controls Expansion Trouble An expansion device or keypad is not reporting to the control panel Zone Lost Press r A wireless or multiplexed zone device is not reporting to the control Press r to identify the zone Zone Low Batt Press r A wireless device has a low battery Press r to identify the zone Zone Tamper Pr...

Страница 25: ...Srn Tamp Siren Tamper A siren or speaker tamper has been detected Tel Flt Telephone Fault A telephone fault or tamper has been detected Exp Trb Expansion Trouble An expansion device or keypad is not reporting to the control Log Full Log Full The event log is full Old events will be pushed out as new ones enter the log Open Open Reports user number date time and partition of opening Close Close Rep...

Страница 26: ...n ended Cross Trip Cross Trip The first zone of a cross zone has been tripped log only Expansion Event Expansion Event An expansion module created an undefined event Partial Arm Partial Arm Reports a closing in the stay mode Listen In Listen In A listen in function has been activated Service Start Service Start Technician is on site Service End Service End Technician is off site Code Entry Code En...

Страница 27: ...the window if there is a long drop to the ground below Set a meeting place outdoors for a headcount of the building occupants Practice escape procedures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it cautiously Be ready to slam the door if smoke or heat ...

Страница 28: ...Programmed Phone Number 1 Programmed Phone Number 2 Programmed Phone Number 3 ZONE LIST ENTRY EXIT 24 STAY MODE 24 HOUR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 For Service Contact ...

Отзывы: