GENERAL LIGHTING INFORMATION
Hillphoenix hot cases are equipped with T-8 lights and feature
specially designed light reflectors in the cornice to improve the
illumination of products. The T-8 electronic ballasts operate
both the cornice and shelf lights, and are located above the
cornice reflectors.
The lighting system has an ON/OFF switch located in the
race-
way, power box or at the inside back of the case
. Once a case
has been properly positioned in the store and an electrician
has connected the lighting circuit, the lights may be turned on
to verify that they are connected and functioning properly.
To ensure peak performance, it is advisable to run the lighting
systems only when the store climate control is on and the case
heat is started.
Note: It is highly recommended that the ambi-
ent store temperature not exceed 80°F
D A N G E R
▲
SHOCK HAZARD
Always disconnect power to case when cleaning,
servicing or confi guring components of the light-
ing system. Failure to do so may result in serious
injury or death.
Fig. 4 T-8 light power cord (WHITE)
W A R N I N G
▲
Using improper DC power supplies may damage
the luminaires, resulting in sub-standard opera-
tion and increased chances of safety issues/
injury.
Fig. 5 T-8 cap and lamp holder
LAMP HOLDER
CAP
SHELF LUMINAIRES
1.
Unplug the white T-8 lamp power cords located at the
inside-back of the case below the lamp being replaced
(Fig. 4).
Fig. 6 Positive engagement
HEATED SHELVES
Unlike the shelf luminaries that are designated with a white re-
ceptacle and cord; the heat receptable and cord designation is
black (Fig. 7). The two, light and heat cords, are located at op-
2.
Carefully seperate the cap from the lamp holder on both
ends of the T-8 lamp (Fig. 5). Simultaneously pull down at
both ends of the old T-8 lamp to remove.
3.
Push and snap the new T-8 lamp into place on the lamp
holder. When the T-8 is properly seated, the lamp button
- which secures the T-8 to the lamp holder - will be clearly
visible through the lamp button hole. The cap should be
pushed all the way down (Fig. 6) for positive engagement
indicator.
Be sure that the T-8 light caps and holders are
still positively engaged. During shipping it is possible
for these to loosen.
C A U T I O N
Be sure that the T-8 light caps and holders are
still positively engaged. During shipping it is pos-
sible for these to loosen. Prior to install check all
T-8 light connection points prior to installation
and supplying power.
▲