10
ASSEMB
ASSEMBL
LY INST
Y INSTR
RUCTIONS
UCTIONS
7 Connect the hose and regulator to the cylinder The propane gas and
.
.
.
.
.
cylinder are sold separately Use a standard 20 lb propane cylinder only
.
Use this fire pit only with a propane vapor withdrawal supply system See
Chapter 5 of the standard for storage and handling of liquefied petroleum
,
/
.
gas ANSI NFPA 58 Your local library or fire department should have this
.
book Storage of an appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance. A cylinder must be stored
-
.
outdoors in a well ventilated area out of reach of children A disconnected
cylinder must have dust caps tightly installed and must not be stored in a
,
.
building garage or any other enclosed area The maximum inlet gas supply
:
.
:
.
pressure 250 psi The minimum inlet gas supply pressure 5 psi
The minimum hourly of 10000 Btu is required input rating for a fire pit for
.
automatic operation at rating less than full input rating The pressure
.
regulator and hose assembly supplied with the appliance must be used
,
The installation must conform with local codes or in the absence of local
,
,
. /
,
codes with national fuel gas code ANSI Z223 1 NFPA54 natural gas and
,
. ,
propane Installation Code CSA B149 1 or propane storage and handling
,
. .
code B149 2