Figure 125, Capacitance Measurement Lead Setup
•
Before connecting the test leads to the two sides of the capacitor
being measured, ensure that the capacitor has been discharged
fully.
The capacitance of a capacitor should be tested
separately, and should not be tested on the circuit itself.
To avoid electric shock, ensure that the capacitors have
been discharged fully before measuring the
capacitance.
While testing the capacitance up to 660 µF, the
maximum time will be 6.6 second. If the capacitor is
damaged or has a leak, the data will not be read. The
Tester will return to normal after the capacitor is
disconnected.
Manual Range and Auto Range
When testing, click
Range Select
to change the value. Click
Auto
Range
to start the Auto Measurement feature
.