Alarm: Alarm triggered recording.
Segment Record: Up to 8 time segments can be set in a day. Device records only in set time
segments.
1)
Set the Start Time, End Time, and Record Type for a time segment.
2)
Optionally, repeat step 1) to configure more time segments.
Step 7
Select day(s) in Copy to Week and click Copy, thus to copy the schedule to other days. Or
repeat the step 5 and 6 to configure.
Step 8
Click OK to go back to previous menu.
Step 9
Optionally, click Advanced to set Advanced Settings.
Pre-Record: The time you set to record before the scheduled time or event. For example,
when an alarm triggered the recording at 10:00, if you set the pre-record time as 5 seconds,
the camera records it at 9:59:55.
Post-Record: The time you set to record after the scheduled time or the event. For example,
when an alarm triggered the recording ends at 11:00, if you set the post-record time as 5
seconds, it records till 11:00:05.
Redundant Record: Enabling redundant record or capture means you save the record and
captured picture in the redundant HDD.
Record Audio: Check the checkbox to enable or disable audio recording.
Expired Time: The expired time is the longest time for a record file to be kept in the HDD, if
the deadline is reached, the file will be deleted. You can set the expired time to 0, and then the
file will not be deleted. The actual keeping time for the file should be determined by the
capacity of the HDD.
Step 10
Click Save to save the settings.
8.7 Alarm Input Recording Settings
Purpose:
Follow the steps to configure the alarm input recording schedule and alarm responding actions.
Step 1
Go to Configuration > Remote Configuration > Alarm Settings > Alarm Input.