Panic Alarm Station Configuration Guide
19
Shield Zone
No events will trigger an alarm.
Sensitivity
The default value is 500 ms.
Audio File
Select an audio file for zone.
Upload Alarm Recovery Report
If check Upload Alarm Recovery Report, the report will be uploaded to the center when the
alarm is restored.
5. Select the zone linkage.
Linked Siren
After the zone is triggered, the selected siren sounds.
Alarm Lamp
After the zone is triggered, the selected alarm lamp is on.
Linked Relay
After the zone is triggered, the selected trigger outputs.
Note
The relay output can set the output delay time, that is, when the zone
is triggered, the trigger outputs a signal, and the trigger will turn off
the output after the output delay time ends. Please refer to the user
manual for the output delay time setting.
Channel
After the zone is triggered, the selected video channel is linked.
Other
You can select Recording Linkage and FTP Linkage.
RRecording Linkage
After the zone is triggered, the event video is recorded.
FFTP Linkage
After the zone is triggered, the event image is captured.
6. Optional: Click Copy to..., copy the zone parameter configuration to other zones.
7. Click Save.
3.3.2 Set Relay
Configure the relay parameters, include the relay name and the output delays.
Steps
1. Click
to enter the Remote Configuration page, go to Output Settings → Relay.
2. Select a relay and click
, set the relay parameters.
Содержание DS-PEA Series