Panic Alarm Station Configuration Guide
18
Figure 3-13 Set Zone Parameters
4. Set zone parameters.
Name
Zone name.
Detector Type
The detector type of the zone.
Zone Type
Four zone type can be set for Non-default zones: Instant Zone, Fire Zone, 24-hour Non-voiced
Zone, Shield Zone.
Instant Zone
In the armed state, as long as the detector connected to the zone is triggered, an alarm is
generated immediately without delay.
Fire Zone
The fire zone must be set to a 24-hour alarm zone. When the fire zone is triggered, start
the external siren/sounder.
24-hour Non-voiced Zone
The detector working in 24-hour non-voiced zone is in an alert state for 24 hours, and will
not be affected by the disarming operation. Once triggered, the information is immediately
uploaded to the center with no alarm sound.