Table 2-1 Descriptions of Terminals and Interfaces 

Name

Name

Name

Name    

No.

No.

No.

No.     Interface

Interface

Interface

Interface    

Description

Description

Description

Description    

Grounding 

A1 

GND 

Grounding 

ALARM OUT 

A2 

AOUT 

Alarm Relay Out 

ALARM IN 

A3 

AIN8 

Zone Detector Input Terminal 8 

A4 

AIN7 

Zone Detector Input Terminal 7 

 

A5 

AIN6 

Zone Detector Input Terminal 6 

A6 

AIN5 

Zone Detector Input Terminal 5 

A7 

AIN4 

Zone Detector Input Terminal 4 

A8 

AIN3 

Zone Detector Input Terminal 3 

A9 

AIN2 

Zone Detector Input Terminal 2 

A10 

AIN1 

Zone Detector Input Terminal 1 

RES 

A11 

RES 

Reserved 

A12 

RES 

Reserved 

Power Supply 

and Network 

Transmission 

B1 

Two-Wire 

Interface 

3 groups of two-wire interfaces (B1 and B2, B3 and B4, B5 

and B6) for power supply and network transmission of the 

indoor station. 

B2 

B3 

B4 

B5 

B6 

 

 

Door Station

Door Station

Door Station

Door Station    Terminals

Terminals

Terminals

Terminals    

 

Figure 6, Door Station Terminals 

 

 

Содержание DS-KIS701

Страница 1: ... Station DS KV8103 IME2 Video Audio Distributor DS KAD709 DS DS DS DS KIS KIS KIS KIS701 701 701 701 Two Two Two Two Wire Wire Wire Wire Video Video Video Video Intercom Bundle Intercom Bundle Intercom Bundle Intercom Bundle Quick Start Guide ...

Страница 2: ... YOU FOR ANY SPECIAL CONSEQUENTIAL INCIDENTAL OR INDIRECT DAMAGES INCLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION SECURITY BREACHES OR LOSS OF DATA OR DOCUMENTATION IN CONNECTION WITH THE USE OF OR RELIANCE ON THIS MANUAL EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY O...

Страница 3: ...Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radioexempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne do...

Страница 4: ...service center If the product does not work properly contact your dealer or the nearest service center Never attempt to disassemble the device yourself We shall not assume any responsibility for problems caused by unauthorized repair or maintenance Do not drop the device or subject it to physical shock and do not expose it to high electromagnetism radiation Avoid the equipment installation on surf...

Страница 5: ...Door Station Terminals 10 Video Audio Distributor Terminals and Interfaces 11 2 2 Wiring 11 3 Installation 13 3 1 Indoor Station Installation 13 3 2 Door Station Installation 14 Flush Mounting 14 Surface Mounting 16 3 3 Video Audio Distributor Installation 17 4 Getting Started 19 4 1 Activate Device via Batch Configuration Tool 19 4 2Editing Network Parameters 21 4 3Adding Device 21 Adding Online ...

Страница 6: ...DS KIS701 Video Intercom Bundle Quick Start Guide QSG DS KIS701 Video Intercom Bundle 080519NA 6 Add Device 25 5 Video Intercom Operation 28 6 Appendix 29 6 1 Installation Notice 29 ...

Страница 7: ...n Station Figure 1 Front Panel Figure 2 Rear Panel Table 1 1 Components Description No No No No Description Description Description Description No No No No Description Description Description Description 1 Power Supply Indicator 8 LCD Display Screen 2 Information Indicator 9 Microphone 3 Alarm Indicator 10 Two Wire Interface 4 Call Accept Decline Key 11 Terminals 5 Unlock Key 12 Serial Port 6 Live...

Страница 8: ...cription Description Description Description 1 Microphone 6 Supplement Light 2 Calling Indicator 7 Loudspeaker 3 Speaking Indicator 8 Call Button 4 Open Door Indicator 9 Tamper Button 5 Built in Camera The calling indicator turns yellow when calling The speaking indicator turns red when speaking The open door indicator turns blue when the door opens 1 3 1 3 1 3 1 3 Video Audio Video Audio Video Au...

Страница 9: ...r Indicator 3 Two Wire Interface 4 RJ 45 Interface 5 Power Supply Interface 2 2 2 2 Terminal and Terminal and Terminal and Terminal and Wiring Wiring Wiring Wiring 2 1 2 1 2 1 2 1 Terminals and Terminals and Terminals and Terminals and Interfaces Interfaces Interfaces Interfaces Indoor Station Indoor Station Indoor Station Indoor Station Terminals Terminals Terminals Terminals Figure 5 Indoor Stat...

Страница 10: ...Terminal 7 A5 AIN6 Zone Detector Input Terminal 6 A6 AIN5 Zone Detector Input Terminal 5 A7 AIN4 Zone Detector Input Terminal 4 A8 AIN3 Zone Detector Input Terminal 3 A9 AIN2 Zone Detector Input Terminal 2 A10 AIN1 Zone Detector Input Terminal 1 RES A11 RES Reserved A12 RES Reserved Power Supply and Network Transmission B1 Two Wire Interface 3 groups of two wire interfaces B1 and B2 B3 and B4 B5 a...

Страница 11: ... GND Grounding A11 PLC Power Input A12 PLC Power Output Video A Video A Video A Video Audio Distributor Ter udio Distributor Ter udio Distributor Ter udio Distributor Terminals and minals and minals and minals and Interfaces Interfaces Interfaces Interfaces The video audio distributor contains nine groups of two wire interfaces for the access of other devices Figure 7 Video Audio Distributor Termi...

Страница 12: ...er Max Distance Max Distance Max Distance Max Distance Door station s Door station s Door station s Door station supplies upplies upplies upplies electric lock electric lock electric lock electric lock power power power power 24 AWG 10 Ω 50 m 50 m 30 m 20 AWG 7 Ω 100 m 100 m 80 m 18 AWG 4 Ω 150 m 150 m 100 m The input voltage for the electric lock is 12 V and the maximum current is 200 mA If using...

Страница 13: ... continuous loop 2 Press the button during a ring to select it The door station prompts Setting succeeded after 1 to 2 mins 3 Check the PLC setting on the indoor station 3 3 3 3 Installation Installation Installation Installation 3 1 3 1 3 1 3 1 Indoor Station Indoor Station Indoor Station Indoor Station Installation Installation Installation Installation Installation Accessory Description Install...

Страница 14: ...tation to the wall mounting plate tightly by inserting the plate hooks into the indoor station s rear panel slots during which the lock catch will lock automatically Figure 10 Hooking the Indoor Station to the Plate 3 2 3 2 3 2 3 2 Door Station Door Station Door Station Door Station Installation Installation Installation Installation The door stations support flush mounting and surface mounting Fl...

Страница 15: ...on Make sure all related equipment is powered off during the installation Connect cables to the door station before mounting 1 Remove the gang box and screws from the packing box 2 Chisel a hole in the wall The hole size should be 104 mm width 163 mm length 39 mm depth 3 Insert the gang box into the hole chiseled in the wall and fasten the gang box with four screws 4 Install the door station into ...

Страница 16: ...e protective shield is 113 4 mm width 184 4 mm length 60 55 mm depth Before Before Before Before You Start You Start You Start You Start Make sure the device in the package is in good condition Make sure all related equipment is powered off during the installation Connect cables to the door station before mounting 1 Remove the door station and screws from the packing box 2 Mount the protective shi...

Страница 17: ...istributor Video Audio Distributor Video Audio Distributor Installation Installation Installation Installation You can mount the video audio distributor with screws or a DIN rail Before Before Before Before You Start You Start You Start You Start Make sure the device in the package is in good condition Make sure all the related equipment is powered off during the installation Check the product spe...

Страница 18: ...acking box Figure 15 Mount the Video Audio Distributor 2 Mount the video audio distributor onto the wall with four screws Mode 2 Mode 2 Mode 2 Mode 2 1 Remove the video audio distributor from the packing box Affix the matching DIN rail onto the wall The suggested DIN rail dimensions are shown below Figure 16 DIN Rail Dimensions 2 Press the red clip upward and lock it to the DIN rail ...

Страница 19: ...t before first use The three devices can be activated in the same way Activation via Batch Configuration Tool and Activation via iVMS 4200 are supported Here we take activation via the Batch Configuration Tool as an example to introduce device activation Refer to the user manual for activation via iVMS 4200 Before You Start Before You Start Before You Start Before You Start Make sure the video aud...

Страница 20: ...s numbers and special characters in order to increase the security of your product We also recommend that you reset your password regularly Especially in high security systems resetting the password monthly or weekly can better protect your product Proper configuration of all passwords and other security settings is the responsibility of the installer and or end user 4 Click the OK OK OK OK button...

Страница 21: ...T Parameters Edit NET Parameters Edit NET Parameters Button 1 Select an online activated device and click the Edit NET Parameters Edit NET Parameters Edit NET Parameters Edit NET Parameters button 2 Change the device IP IP IP IP A A A Address ddress ddress ddress and G G G Gateway ateway ateway ateway A A A Address ddress ddress ddress to the same subnet as your computer 3 Enter the password and c...

Страница 22: ...ne device or hold down the Ctrl Ctrl Ctrl Ctrl or Shift Shift Shift Shift key to select multiple devices in the online devices list Figure 22 Online Devices Interfaces 2 Click the button to pop up the login dialog box Figure 23 Login Dialog Box 3 Enter the user name and password 4 Click the OK OK OK OK button to save the settings Only devices successfully logged in will be added to the device list...

Страница 23: ...ou add devices by IP Address IP Address IP Address IP Address or IP IP IP IP Segment Segment Segment Segment the devices should be online 4 4 4 4 4 4 4 4 Set Indoor Set Indoor Set Indoor Set Indoor Station Station Station Station Set Room Set Room Set Room Set Room No No No No You can set the indoor station no via the batch configuration tool remotely You can dial the Roo Roo Roo Room No m No m No...

Страница 24: ...among devices Make sure you have activated the indoor station and add it to the batch configuration tool 1 Click Remote Remote Remote Remote Configuration Configuration Configuration Configuration Network Network Network Network Linked Linked Linked Linked Network Network Network Network Configuration Configuration Configuration Configuration to enter the L L L Linked inked inked inked Network Con...

Страница 25: ... a user account for iOS or Android 1 Search for Hik Connect in the iOS App Store or Google Play to download and install the app or Figure 28 iOS App Store Google Play 2 Launch the app and follow the on screen instructions to register a user account 3 Start the Hik Connect app and log in to the app Add Device Add Device Add Device Add Device Before You Start Before You Start Before You Start Before...

Страница 26: ... 30 Device Result 3 Tap Add Add Add Add to add the door station Mode 2 Add Device via Serial No Mode 2 Add Device via Serial No Mode 2 Add Device via Serial No Mode 2 Add Device via Serial No You can add the door station to the app by entering the device serial no on the indoor station interface 1 On the app home page tap on the upper right corner to add the device ...

Страница 27: ... Verification Code 3 Enter the device verification code and click OK OK OK OK You can get the serial no on the indoor station Maintenance Maintenance Maintenance Maintenance page Settings Settings Settings Settings Maintenance Maintenance Maintenance Maintenance The admin password of the indoor station is 88 88 88 888999 8999 8999 8999 The default device verification code is ABCDEF ABCDEF ABCDEF A...

Страница 28: ...oms between you and the resident connect you can speak to the resident and the live view of door station will be displayed on the connected indoor station When the door station calls the resident the door station will detect the video brightness automatically If the brightness is lower than the expected threshold the supplement light will be enabled When the supplement light is enabled the key bac...

Страница 29: ... Installation Notice Installation Notice Installation Notice While installing the door station make sure that the distance between any two devices is as far as possible to avoid audio feedback howling and echoing The distance between any two devices is recommended to be longer than 33 feet 10 meters Devices here refer to indoor station door station and video audio distributor ...

Страница 30: ......

Отзывы: