Installation Guide
DS-72xx Series DVR
Hikvision EURO, Inc. DS-72xx Series Embedded Net DVR Installation Guide and Quick Start Guide
15
There are 4 jumpers (JP4, JP5, JP6, and JP7) on the motherboard, each corresponding with one alarm output. By default, jumpers
are connected. To connect an AC load, jumpers should be removed.
Note:
An external relay is needed to prevent electric shock when connecting to an AC load.
Alarm Connection:
To connect alarm devices to the DVR:
1.
Disconnect
pluggable block
from the ALARM IN /ALARM OUT terminal block.
2.
Unfasten stop screws from the
pluggable block
, insert signal cables into slots and fasten stop screws. Ensure signal cables are
in tight.
3.
Connect
pluggable block
back into terminal block.
RS-485 Connection:
To connect RS-485 devices to the DVR:
1.
Disconnect
pluggable block
from the RS-485 terminal block.
2.
Unfasten stop screws from the
pluggable block
, insert signal cables into slots and fasten stop screws. Ensure signal cables are
in tight.
3.
Connect
pluggable block
back into terminal block.
Note:
Make sure the pan/tilt receiver unit is connected to the T+ and T- of the DVR.