HD-TVI Speed Dome DS-2AE7232TI-A User Manual
UM THD DS-2AE7232T-x 020519NA
35
2.
Choose the zone number:
A.
Move the cursor to
ZONE NUM.
and click
IRIS+
button to enter the editing mode.
B.
Click the up and down buttons to select the zone number to be configured.
C.
Click
IRIS+
again to confirm the settings and exit the editing mode of this column.
NOTE:
Up to eight zones can be configured.
3.
Configure the zone area.
A.
Move the cursor to
EDIT ZONE
and click
IRIS+
button to enter the editing mode.
B.
You can see
SET LEFT LIMIT
on the screen. Click the direction buttons to set the left limit.
C.
Follow the prompts on the screen to set the right limit.
D.
Click
IRIS+
button to save the settings and exit.
4.
Set the zone status and scan status.
•
ZONE STATUS:
The zone status just indicates the current status of the zone.
•
SCAN STATUS:
You can set the scan status to
ON/OFF
to enable/disable the scanning in the zone.
NOTE: ZONE STATUS
is not editable. After you edit the zone, it will switch to
ON
automatically; if you
delete the zone, the
ZONE STATUS
will switch to
OFF
.
5.
Clear the zone settings. Move the cursor to
CLEAR ZONE
, click
IRIS+
to clear all the settings of the
current zone, and click
IRIS+
again to confirm the settings and exit.
Configuring Smart Settings
Purpose:
Set the smart settings to
ON
to automatically track the moving object, and meanwhile adjusts the focus
and the position to set the target in the center of the field of view.
1.
Move the cursor to enter the smart setting submenu:
MAIN MENU > DOME SETTINGS > SMART SETTINGS
.