![HIKVISION DeepinMind iDS-6700NXI Series Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/hikvision/deepinmind-ids-6700nxi-series/deepinmind-ids-6700nxi-series_user-manual_2132235062.webp)
DeepinMind Series NVS User Manual
iDS-67 00 Deep inMind Series NVS User Manua l
61
Threshold:
Range [0-2s], the threshold for the time of the object loitering in the region.
If you set the value as 0, alarm is triggered immediately after the object entering the
region.
5)
Drag the slider to set the sensitivity value.
Sensitivity
: Range [1-100]. It stands for the percentage of the body part of an
acceptable target that goes across the pre-defined line.
Sensitivity = S1/ST*100
S1 stands for the target body part that goes across the pre-defined line. ST stands for
the complete target body.
Example: if you set the value as 60, the action can be counted as a line crossing action
only when 60 percent or more body part goes across the line.
The
Sensitivity
of the detection is supported by certain camera models. Refer to actual display for
details.
6)
Drag the slider to set the percentage.
Percentage
: Range [1-100]. Percentage defines the ratio of the in-region part of the
object which can trigger the alarm. For example, if the percentage is set as 50%, when
the object enters the region and occupies half of the whole region, the alarm is
triggered.
7)
Repeat the above steps to configure other regions. Up to 4 regions can be set. You can
click the
Clear
button to clear all pre-defined regions.
Step 6
Click
Arming Schedule
to set the arming schedule. Refer to
Step 6
in
Chapter 6.1.1
Step 7
Click
Linkage Method
to select the linkage methods for intrusion detection. Refer to
Step 7
in
Chapter 6.1.1
Step 8
Click
Save
.
6.2.4 Configuring Line Crossing Detection
Line crossing detection function detects people, vehicle or other objects which cross a pre-defined
virtual line, and some certain actions can be taken when the alarm is triggered.
Line crossing detection function varies according to different camera models.
Step 1
Go to
Configuration
>
Event
>
Smart Event
>
Line Crossing Detection
.