background image

Regulatory Information 

FCC Information 
Please take attention that changes or modification not 
expressly approved by the party responsible for 
compliance could void the user’s authority to operate 
the equipment. 
FCC compliance: This equipment has been tested and 
found to comply with the limits for a Class A digital 
device, pursuant to part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection 
against harmful interference when the equipment is 
operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy 
and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to 
radio communications. Operation of this equipment in a 
residential area is likely to cause harmful interference in 
which case the user will be required to correct the 
interference at his own expense. 
FCC Conditions 
This device complies with part 15 of the FCC Rules. 
Operation is subject to the following two conditions: 
1. This device may not cause harmful interference. 
2. This device must accept any interference received, 
including interference that may cause undesired 
operation. 
 
EU Conformity Statement 

This product and - if applicable - the 
supplied accessories too are marked with 
"CE" and comply therefore with the 
applicable harmonized European 

standards listed under the Low Voltage Directive 
2014/35/EU, the EMC Directive 2014/30/EU, the RoHS 
Directive 2011/65/EU. 

2012/19/EU (WEEE directive): Products 
marked with this symbol cannot be 
disposed of as unsorted municipal waste in 

the European Union. For proper recycling, 
return this product to your local supplier 
upon the purchase of equivalent new 

equipment, or dispose of it at designated collection 
points. For more information see: www.recyclethis.info. 
2006/66/EC (battery directive): This product contains a 

battery that cannot be disposed of as 
unsorted municipal waste in the European 
Union. See the product documentation for 
specific battery information. The battery is 
marked with this symbol, which may 

include lettering to indicate cadmium (Cd), lead (Pb), or 
mercury (Hg). For proper recycling, return the battery 
to your supplier or to a designated collection point. For 
more information, see: www.recyclethis.info. 

 

Industry Canada ICES-003 Compliance 
This device meets the CAN ICES-3 (A)/NMB-3(A) 
standards requirements.

 

 

Warning 
This is a class A product. In a domestic environment this 
product may cause radio interference in which case the 
user may be required to take adequate measures. 

 

Содержание D0T PIR Series

Страница 1: ... the models below Type Model Type I Camera DS 2CE11D0T PIRL DS 2CE11D0T PIRLP Type II Camera DS 2CE12D0T PIRL This manual may contain several technical incorrect places or printing errors and the content is subject to change without notice The updates will be added to the new version of this manual We will readily improve or update the products or procedures described in the manual 01000020200821 ...

Страница 2: ...peration EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply therefore with the applicable harmonized European standards listed under the Low Voltage Directive 2014 35 EU the EMC Directive 2014 30 EU the RoHS Directive 2011 65 EU 2012 19 EU WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste...

Страница 3: ... mounting is adopted If smoke odor or noise rise from the device turn off the power at once and unplug the power cord and then contact the service center Never attempt to disassemble the camera by unprofessional personal Cautions Do not drop the camera or subject it to physical shock Do not touch senor modules with fingers Do not place the camera in extremely hot cold the operating temperature sha...

Страница 4: ...from liquid while in use for non water proof device While in delivery the camera shall be packed in its original packing or packing of the same texture Mark Description Table 0 1 Mark Description Mark Description DC Voltage ...

Страница 5: ...DC Lens White Light Source Figure 1 2 Overview of Type II Camera Installation 2 Installation Before you start Make sure that the device in the package is in good condition and all the assembly parts are included Make sure that all the related equipment is power off during the installation Check the specification of the products for the installation environment Check whether the power supply is mat...

Страница 6: ...wall and secure the camera with supplied screws Figure 2 2 Fix the Camera to the Ceiling Note The supplied screw package contains self tapping screws and expansion bolts For cement wall ceiling expansion bolts are required to fix the camera For wooden wall ceiling self tapping screws are required 4 Route the cables through the cable hole or the side opening 5 Connect the corresponding power cord a...

Страница 7: ...on the ceiling wall 2 Drill screw holes and the cable hole in the ceiling wall according to the holes of the drill template Figure 2 4 Drill Template of Junction Box 3 Take apart the junction box and align the screw holes of the bullet camera with those on the Junction box cover 4 Fix the camera on the junction box s cover with supplied screws Junction Box Cover Figure 2 5 Fix the Camera on the Ju...

Страница 8: ...e drill template and the cable hole optional on the ceiling Ø 68 mm 2 68 Ø 55 mm 2 17 Template Side Opening Screw Hole Screw Hole Screw Hole Ø 18 mm 2 68 Figure 2 8 Drill Template Note Drill the cable hole in the center of the drill template when adopting ceiling outlet to route the cable 3 Route the cables through the cable hole optional or the side opening 4 Fix the camera to the ceiling with su...

Страница 9: ... Tighten the No 3 adjusting screw 2 2 2 Ceiling Wall Mounting with Junction Box Before you start You need to purchase a junction box separately Steps 1 Paste the drill template on the ceiling wall 2 Drill screw holes and the cable hole optional in the ceiling wall according to the holes of the drill template Figure 2 11 Drill Template Note Drill the cable hole when adopting ceiling outlet to route...

Страница 10: ...e installation 3 Menu Description Please follow the steps below to call the menu Note The menu description part is only for your reference It might have differences due to the specific model that you have Steps 1 Connect the camera with the TVI DVR and the monitor shown as the figure 3 1 Camera TVI DVR Monitor Figure 3 1 Connection 2 Power on the analog camera TVI DVR and the monitor to view the i...

Страница 11: ...he direction arrow to control the camera 1 Click up down direction button to select the item 2 Click Iris to confirm the selection 3 Click left right direction button to adjust the value of the selected item 3 1 VIDEO FORMAT You can select the video format as 2MP 25fps or 2MP 30fps 3 2 EXPOSURE EXPOSURE MODE You can set the EXPOSURE MODE as GLOBAL BLC HLC or DWDR GLOBAL GLOBAL refers to the normal...

Страница 12: ...time and it is better to turn the IR LIGHT on in poor light conditions IR LIGHT You can turn on off the IR LIGHT to meet the requirements of different circumstances SMART IR The Smart IR function is used to adjust the light to its most suitable intensity and prevent the image from over exposure The SMART IR value can be adjusted from 0 to 3 The greater the value is the more obvious effects are AUT...

Страница 13: ...Standard or HIGH SAT High Saturation WHITE BALANCE White balance the white rendition function of the camera is to adjust the color temperature according to the environment It can remove unrealistic color casts in the image You can set WB mode as AUTO or MANUAL AUTO Under AUTO mode white balance is being adjusted automatically according to the color temperature of the scene illumination MANUAL You ...

Страница 14: ... you can select the ALARM MODE as SOLID or FLASHING FUNCTIONS WHITE LIGHT ALARM MODE TIME SETTINGS PIR LEVEL PIR DET MODE BACK EXIT SAVE EXIT OFF FLASHING 10 S 3 OUTDOOR Figure 3 6 FUNCTIONS SOLID Select the ALARM MODE as SOLID In this way the white light source turns on when the PIR module received the alarm signal FLASHING Select the ALARM MODE as FLASHING In this way the white light source flas...

Страница 15: ... DET MODE switch 3 6 FACTORY DEFAULT Reset all the settings to the factory default 3 7 EXIT Move the cursor to EXIT and click Iris to exit the menu 3 8 SAVE EXIT Move the cursor to SAVE EXIT and click Iris to save the settings and exit the menu UD12794B A ...

Отзывы: