![Highway Care BG800 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/highway-care/bg800/bg800_product-and-installation-manual_2130918034.webp)
ENGINEERING YOUR SAFETY
WWW.HIGHWAYCARE.COM
Rev. C
–
10/18
©2018 Highway Care Limited. All Rights Reserved.
Page
34
of
61
Different Anchor Types
Installation
The list below are the most commonly used
foundation anchors. Please contact Highway
Care for alternative anchoring solutions.
Note: Always follow the installation instructions
supplied by the fixing manufacturer. These may
differ to the guidelines below.
Flat Top Pin & Flag Top Pins
Flat Top Pin (BG-21-20) Flag Top Pin (BG-21-24)
1.
Drill a hole with a diameter of 32mm and a
depth of 450mm.
2.
Clean the hole using an air line and blow
pipe or similar.
3.
Position the anchor plate.
4.
Fit either a flag top of flat top pin in the hole.
5.
Drive the pin into the ground using a large
hammer/sledge hammer as required.
Note: Flag top pins should not be used on any
external anchor. Pins are normally used on
temporary installations only.
Mechanical Anchor Bolt
FMA-24-185-YZ
1.
Drill a hole with a diameter of 30mm and a
depth of 250mm.
2.
Clean out the hole using an air line and blow
pipe or similar.
3.
Insert the complete mechanical anchor into
the hole.
4.
Tighten the anchor to the manufacturer’s
specification.
Resin Anchor Studding
FATB-24-460-GLV
Note: this part No. does not include the resin
1.
Drill a hole with a diameter of 28mm and a
depth of 450mm.
2.
Clean the hole using an air line blow pipe or
similar.
3.
Mix the resin as specified by the
manufactures specification.
4.
Pour the required volume of resin into the
hole; leave approximately 100mm without
resin at the top of the hole as this may need
to be increased or decreased to suit each
application.