Terminal Installation
BG800 is always secured at its start and end by
a full height terminal. When a full height
terminal is used facing oncoming traffic, it must
be transitioned to an approved end termination
(such as a crash cushion). Details of crash
cushion transitions and connections are
available from the crash cushion supplier.
Full height terminal with hood cover
Full height terminal with hood cover removed
for anchoring and/or crash cushion installation
Crash cushion installed in front of full height
terminal
Installation is normally started from the end of
the BG800 and laid in the direction of traffic
flow. Sometimes when a long length of BG800 is
to be installed and site conditions allow, the
installation can commence at any point along
the length of the run, using a section of BG800
with two male ends as the first unit to be placed
and subsequent standard sections laid
outwards in both directions from this section
simultaneously, this double male quick link
section can easily be identified by applying a
paint mark to the top external face of the
barrier.
Double male section
Full height terminals (male and female)
anchoring positions are indicated below.
At the bolted joint there will either be an
external anchor shoe or internal anchor shoe.
Note: It is recommended that no drilling takes place
until at least the next two barrier sections have
been installed.