![HighPoint RocketRAID 4520 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/highpoint/rocketraid-4520/rocketraid-4520_user-manual_2130680061.webp)
61
Number of drives per spin up:
Select the number of disks per spin up
(eg. 2 drives powered on every 2 seconds.)
Delay between spin up (seconds):
Time interval between spin ups.
Spin down idle disk (minutes)
Hard drives can be instructed to spin
down when there is no disk activity for set
period of time.
Enable automatic rebuild
When enabled, any new disk attached to
the controller will automatically be used
to rebuild a critical RAID array
Continue Rebuilding on error
Disk bad sectors can interrupt the RAID
rebuild process. Enabling this option will
allow rebuilding to continue, ignoring bad
sectors.
Rebuild Priority:
This setting determines how HBA
resources should be directed towards
repairing broken RAID arrays.
Provide INT13 support
INT13 is the HBA’s boot function
Use single BCV entry
When enabled (and if HBA hosts several
logical disks) only the first disk will be
reported to the motherboard BIOS.
This setting could be useful when bottom
from a disk or array attached to your
RocketRAID HBA.
Stop on error
(Default: Enabled)
If disabled, the host
adapter BIOS menu will bypass array or
device errors when booting the system