Installation & Adjustments
Predator SS Turntable Stretch Wrapper Operation Manual
Highlight Industries, Inc. ● 2694 Prairie S
W, Wyoming
, Mi 49519 ● 1
-800-531-2465
22
Scale Calibration Procedure
Note
Highlight Industries, Inc calibrates the scale before shipment using known
weights. The values stored in theses settings are custom per scale and
machine. Do not change these values unless directed to do so by Highlight
personnel.
Step 1: Navigate the scale menu t
o parameter “F 16.”
Step 2: Press the “ZERO” button ONCE. This enters the Zero Calibration Menu. The
display will momentarily show “C 0” followed by a value.
Step 3: After making sure that there are no test weights on the machine press the “ZERO”
button again. The display will zero.
Step 4: Press the “SET / NET” button to save the zero point value. The display will show
“EndC0” momentarily then revert to parameter F16.
Step 5: Navigate to parameter “F 17.”
Step 6: Press the “ZERO” button ONCE. This ent
ers the Span Calibration Menu. The
display will momentarily show “C 1” followed by a value with one flashing digit. This value
will be zero with the decimal point parameter selected in F10.
Step 7: Place a known weight on the machine. Ensure that the test weight is below the
maximum capacity of the scale and above 1% of the maximum capacity of the scale.
Step 8: Key in the weight of the test weight using the buttons on the screen. Press the
“TARE / <<” button to select the digit to the left of the current
position. Press “PRINT / >>”
to select the digit to the right of the current position. Press “UNITS” to increase the value of
the digit and press “ZERO” to decrease the value of a digit.
Step 9: Once the weight of the test weight is keyed in exactly, pre
ss the “SET / NET” button
to save the value. If the calibration was successful the display will read “EndC1”
momentarily, and then revert back to “F17”. If “Err0” is displayed the test weight is larger
than the full capacity of the scale. If “Err1” is disp
layed the test weight is below 1% of the
full capacity of the scale. If “Err2” is displayed the internal resolution of the scale is not high
enough to accept the calibration value.
Содержание Predator SS
Страница 4: ...1 Highlight Industries Inc Predator SS Turntable Stretch Wrapper Operation Manual General Information...
Страница 10: ...2 Highlight Industries Inc Predator SS Turntable Stretch Wrapper Operation Manual Specifications...
Страница 14: ...3 Highlight Industries Inc Predator SS Turntable Stretch Wrapper Operation Manual Installation Adjustments...
Страница 24: ...4 Highlight Industries Inc Predator SS Turntable Stretch Wrapper Operation Manual Operation Instructions...
Страница 31: ...5 Highlight Industries Inc Predator SS Turntable Stretch Wrapper Operation Manual Maintenance...
Страница 36: ...6 Highlight Industries Inc Predator SS Turntable Stretch Wrapper Operation Manual Trouble shooting...
Страница 44: ...7 Highlight Industries Inc Predator SS Turntable Stretch Wrapper Operation Manual Technical References...
Страница 65: ...8 Highlight Industries Inc Predator SS Turntable Stretch Wrapper Operation Manual Notes...