20
ELECTRICAL CONNECTION
The installation of this appliance and the connection to the electrical network must only
be carried out by a qualified electrician according to local rules and regulations.
.
Ensure that no parts are under tension after the installation.
The data p l a t e must be placed on the cooktop casing near the connection box.
Connection to the mains electricity must be made using an earthed plug, which must be
accessible after installation, or via an omnipolar circuit breaking device with a contact
opening of at least 3 mm.
The electrical circuit must be separated from the network by suitable devices, for example:
circuit breakers, fuses or contactors.
If the appliance is not fitted with an accessible plug, a means of disconnecting the
cooktop must be incorporated into the installation, in accordance with local rules
and regulations.
The power supply cable must be positioned so that it does not touch any of the hot parts
of the cooktop or oven.
Caution!
This appliance must only be connected to a 230 V~ 50/60 Hz network.
Connect the earth wire.
Follow the connection diagram.
The connection box is located underneath at the back of the cooktop casing. To open the cover,
use a medium screwdriver. Place it in the slits and open the cover.
CONNECTION OF THE COOKTOP FOR HIX604B1
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz
1 Phase + N
3 x 2,5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz
2 N
4 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
* calculated with the simultaneous factor following the standard EN 60 335-2-6
CONNECTION OF THE COOKTOP FOR HIX906B1
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz
1 Phase + N
3 x 4 mm²
H 05 VV - F
H 05 RR - F
40 A *
400V~ 50/60Hz
2 N
4 x 2.5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz
3 N
5 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Caution! Be careful that the cables are correctly engaged and tightened.
The manufacturer cannot be held responsible for any incident resulting from incorrect
connection or which could arise from the use of an appliance which has not been
earthed or has been equipped with a faulty earth connection.
Содержание HIX604B1
Страница 1: ...USE AND CARE INDUCTION COOKTOPS HIX604B1 HIX906B1...
Страница 2: ......
Страница 17: ...17 Disconnect and reconnect the cooktop...
Страница 21: ...20509 0...