1

 

System Overview 

MaxiProx® is a self-contained proximity reader.  The two-piece polycarbonate enclosure has an O-ring 
that weather seals the enclosure pieces together and a cable fitting that seals the cable entry.  The 
water-resistant unit is designed for outdoor use.  The enclosure is mountable on a single gang 
electrical box. A bi-color LED and audible tone provide user feedback. Configurable open collector data 
outputs provide the data to the Host.  Configurable DIP Switches and jumpers provide choice of data 
interfaces between Wiegand, Clock-and-Data, RS 232 and RS422.  The data interface is configured as 
ordered from the factory, but can be changed in the field - please contact 

HID Technical Support

 for 

assistance.  A tamper switch can alert the Host when the enclosure is opened.  Internal DIP Switches 
and jumpers provide for configuration of the outputs, audible tone and LED control options.  Installation 
of the MaxiProx reader consists of mounting, connecting the cable to the Host and +12VDC or 
+24VDC power, verifying the DIP Switch and jumper settings, verifying Auto-tune, and verifying the 
reading of a transponder. 

1.1

 

Operation 

Transponders (Proximity Cards or ProxKeys) are presented to the front of the MaxiProx. The LED is 

red

 when ready to read a transponder. The LED turns 

green

 and the beeper sounds when the 

transponder is read and the message is transmitted to the Host computer or interface panel. The 
system is ready for another transponder as soon as the LED returns to 

red

. There is an anti-passback 

delay of about one and a half seconds before it will read the same card. The LED flash is typically 250 
milliseconds long. The operation of the LED and beeper may be controlled by the Host, in which case 
the actual operation will depend on the programmed timing of the Host. 

1.2

 

Parts List 

 

MaxiProx reader 

Qty 1 (included) 

Installation Manual 

Qty 1 (included) 

3. 

Cable Fitting 

Qty 1 (included) 

Label for front cover - HID logo 

Qty 1 (included) 

#6-32 x 1" flat head screw, for upper-left base mount 
screw   

Qty 1 (included) 

#6-32 x 1" black screw, for gang-box mounting 

Qty 2 (included) 

#6-32 x .75" flat head screw, for front cover mounting 

Qty 1 (included) 

Cable, 5 conductor, 22 AWG  (Alpha 1295 C or 
equivalent) 

See Install Cable 

Power Supply – 2.0 A, Linear or switching regulated 

+24VDC, nominal (+21 TO 28.5VDC) 

Factory Default – P2 Shunt Jumper 
between P2 and P3 for 24V operation. 

For Europe, use ALTRONIX SMP3            

(USER SUPPLIED TRANSFORMER AND 
BATTERY) 

10 

+12VDC Shunt Jumper – P2-1 to P2-2 for 12VDC 
operation 

+12VDC, nominal (+11.6 to +20.9VDC) 

For Europe , use ALTRONIX SMP3 

(USER SUPPLIED TRANSFORMER AND 
BATTERY) 

 

Содержание MaxiProx DFM Reader - 5375

Страница 1: ...MaxiProx DFM Reader 5375 INSTALLATION GUIDE 5375 901 Rev E 1 March 2012 2008 2012 HID Global Corporation All rights reserved 15370 Barranca Parkway Irvine CA 92618...

Страница 2: ...witch and Jumper Settings 7 2 8 Tamper Switch 9 2 9 Mounting 9 2 10 Power Supply 9 2 11 Auto tune Operation 10 2 12 Reader Testing 10 2 13 Power Up Tune 10 2 14 Periodic Auto tune 10 2 15 Supervisor M...

Страница 3: ...15 Table 10 Data Pulses Timing Parameters 15 Table 11 Data Timing Timing Chart 17 HID GLOBAL HID the HID logo and MaxiProx are the trademarks or registered trademarks of HID Global Corporation or its...

Страница 4: ...n Transponders Proximity Cards or ProxKeys are presented to the front of the MaxiProx The LED is red when ready to read a transponder The LED turns green and the beeper sounds when the transponder is...

Страница 5: ...n Failure to install the P2 shunt jumper in the correct position will permanently damage the MaxiProx unit The following states the P2 shunt jumper installation Power Supply Voltage Jumper Position 24...

Страница 6: ...297 C or equivalent A 22 AWG twisted pair shielded stranded cable Belden 9330 or equivalent is often required for the tamper switch Follow the recommendations of the manufacturer of the Host system If...

Страница 7: ...2 2 7 Dip Switch and Jumper Settings Verify the default settings according to the model ordered or set the DIP Switches and Jumper positions according to the following Table 3 DIP Switch and Jumper Se...

Страница 8: ...term OFF OFF ON OFF OFF OFF 2 3 Table 7 Baud Rate Chart RS232 and RS422 BAUD SW1 7 SW1 8 SW2 1 9600 ON ON ON 4800 OFF ON ON 2400 ON OFF ON 1200 OFF OFF ON Table 8 Switch Description SW5 Switch Default...

Страница 9: ...vailable on TB1 Pins 4 and 5 and are either normally open or normally closed dependent upon the position of the jumper on P1 Install the jumper to connect pins 1 and 2 if you need the normally open co...

Страница 10: ...n Flash Beep on valid read SW1 5 on 2 13 Power Up Tune Following this initial power up sequence the reader will perform power up Auto tune It will beep and turn the access LED amber for 1 second to in...

Страница 11: ...r screw Make sure that the Auto tune indicator LED remains in a steady green state If the LED is red remove the cover and re mount the unit using a non metallic spacer to position it further away from...

Страница 12: ...5 VDC DEFAULT SHUNT PINS 1 AND 2 11 20 VDC SW1 SW2 SW5 SW5 1 SW5 2 SW5 3 SW5 4 SW5 5 SW5 6 SW5 7 SW5 8 DATA 1 ISOLATION DATA 0 ISOLATION RS422 TERM RESISTOR RS 232 422 LINE 1 RS 232 422 LINE 2 NOT USE...

Страница 13: ...l being received from the card by re directing excite field transmissions into the receiver circuitry Moving the reader away from the metal objects reduces energy loss Try to limit the amount of metal...

Страница 14: ...generally sends out the same bit pattern as previously programmed on the card Consult factory for variations to this method A 26 bit Wiegand format will be used in the examples below The 26 bits of t...

Страница 15: ...ice on a reader is measured at the control panel that is controlling the input device with reference to the signal ground at the panel 4 1 3 Signal Levels The Data One Data Zero and LED Control conduc...

Страница 16: ...form of a parity bit Each character consists of five bits The maximum number of characters for a magnetic strip card encoded on Track 2 are 40 this product will output less than 40 characters The dat...

Страница 17: ...e adjustable for cards traveling at 4 inches per second to 20 inches per second This relates to bit times of 3 3 ms and 666us respectively There are 75 bits per inch on Track 2 4 2 3 Output signal Lev...

Страница 18: ...hp F iiiip start data a data b data c data d data e data f data g data h end LRC The message structure follows the ISO ABA Track 2 standard The first character is a start sentinel B hex which is follo...

Страница 19: ...um The checksum is calculated by first grouping the message data into the pairs CC DD DD DD DD DD Each pair of characters represents one byte of data Then each pair of characters is converted from ASC...

Отзывы: