background image

Page 2 of 38 

September 2016  

 

 

EntryProx User Manual, 4045-905, Rev. C.4 

Copyright 

©2002 - 2016 HID Global Corporation/ASSA ABLOY AB. 

All rights reserved.  This document may not be reproduced, disseminated or republished in any 

form without the prior written permission of HID Global Corporation. 

 Trademarks 

HID GLOBAL, HID, the HID logo, and EntryProx are the trademarks or registered trademarks of HID 

Global Corporation, or its licensors, in the U.S. and other countries. All other trademarks, service 

marks, and product or service names are trademarks or registered trademarks of their respective 

owners. 

Revision History 

Date 

Description 

Version 

September 2016 

Removed references to PDAs and DCD/DTDs, which are no longer 

supported. 

C.4 

March 2014 

Added French translation of warning statement. 

C.3 

February 2007 

Reformatted, added correct IP statement 

C.2 

August 2006 

Error correction in EntryProx User Guide 4045-905 C.0 - page 33, 

add ".com" to hidcorp URL 

C.1 

May 2006 

Added PDA support for logging data. 

C.0 

Contacts 

For additional offices around the world, see 

www.hidglobal.com

 corporate offices. 

North America 

Asia Pacific 

611 Center Ridge Drive 
Austin, TX 78753 
USA 
Phone:  866-607-7339  
Fax:      949-732-2120 

19/F 625 King’s Road 
North Point, Island East 
Hong Kong 
Phone:  852 3160 9833 
Fax:      852 3160 4809 

Europe, Middle East and Africa 

Brazil 

Haverhill Business Park Phoenix Road 
Haverhill, Suffolk CB9 7AE 
England 
Phone:  44 (0) 1440 711 822 
Fax:      44 (0) 1440 714 840  

Condomínio Business Center 
Av. Ermano Marchetti, 1435 
Galpão A2 CEP 05038-001 
Lapa - São Paulo/SP 
Brazil 
Phone:        55 11 5514-7100 

HID Global Customer Support: 

www.hidglobal.com/support

 

 

 

Содержание ENTRYPROX

Страница 1: ...ENTRYPROX USER MANUAL 4045 905 Rev C 4 September 2016 hidglobal com ...

Страница 2: ...r supported C 4 March 2014 Added French translation of warning statement C 3 February 2007 Reformatted added correct IP statement C 2 August 2006 Error correction in EntryProx User Guide 4045 905 C 0 page 33 add com to hidcorp URL C 1 May 2006 Added PDA support for logging data C 0 Contacts For additional offices around the world see www hidglobal com corporate offices North America Asia Pacific 6...

Страница 3: ...tion 16 4 6 2 Secure Installation 17 4 7 Installation and Compliance for UL 294 18 4 8 Metal or Plastic Single Gang J Box 18 4 9 Wall Mounting 19 5 Wiring 20 5 1 Gate Actuator 20 5 2 Auxiliary Relay 21 5 3 Request to Exit Input 21 6 Programming 22 6 1 Programming Command Sequences 22 6 2 LED Indication during Program Mode 23 6 3 Changing the Master Code 23 6 4 Preparing to Program Card 23 6 5 PIN ...

Страница 4: ...em Defaults Only 30 8 4 Erasing Entire Memory Resetting System Defaults 30 8 5 Turning KeyPress Audible Feedback On Off 30 8 6 Turning Keypress Visual Feedback On Off 31 8 7 Auto Entry Enable 31 9 Wiegand Mode 32 9 1 PIN Code Output In Wiegand Mode 32 9 2 LED Control Options for Wiegand Mode 32 10 Programming Commands 33 11 LED Sounder Status Indications 36 Appendix A Users Chart for Record Keepin...

Страница 5: ...hange the Master Code from the factory default User Location 1 PIN Code 1234 to a new code 1 6 digits Programming commands will not work until the default Master Code is changed Keep a record of the new code in a safe place Program the New Master Code into Location 0 Once this is done the default Master Code in User Location 1 can now be reprogrammed for normal access control use Note The Rev C En...

Страница 6: ...tch of cards or tags encoded in any format can be sequentially presented to the reader by entering a single keypad command 2 1 Unit Capacity The EntryProx unit can accommodate up to 2 000 users Each user is assigned to a User Location numbered 1 2000 which can have a card key tag a PIN code or both a card key tag and a PIN code User Location 0 is reserved for the Master Code used for programming o...

Страница 7: ...eripherals Mechanical Height 5 25 in 13 3 cm Width 2 75 in 7 cm Depth 1 625 in 4 1 cm Relay Outputs Main Relay Aux Relay Form C switches up to 1A inductive load 2A resistive 30VDC Sounder 4000 Hz defeatable LEDs Bi Color red green Amber Infrared 2 5 Default Settings The EntryProx unit is shipped with the following default settings Parameter Default Setting Master Code User Location 1 Code must be ...

Страница 8: ... Keypad Unit I Silicone Rubber Cushion B Controller Keypad Backplate J Self Adhering Pads C Cable Assemblies K 2 pin Jumper1 D Antenna Backplate L Filler Piece E Antenna Housing M Lithium Coin Cell Battery2 3 N Cover screws hex and tamper2 F Blank Label G Mounting Screws O Hex wrench2 H Press to Exit Label 1 Pre installed on main board connector P2 pins 5 6 2 Not shown in the following figure 3 Ca...

Страница 9: ...WG Request to Exit cable ALPHA 2421C 18AWG or ALPHA 1292C 22AWG only if using remote switch Optional tamper screw bit only if tamper screw is used Ademco 945T or PR 20451 magnet and reed switch or equivalent for UL 294 compliance CAUTION Replace Battery with Panasonic BR1225 only Use of another battery may present a risk of fire or explosion Battery may explode if mistreated Do not recharge disass...

Страница 10: ...case CAUTION If your installation must comply with the UL 294 Standard for Access Control see Section 4 3 Controlled Keypad Wiring 4 1 Precautions for Outdoor Installations Water damage is a key cause of unit malfunction causing corrosion or short circuits When mounting the unit in an area that will be exposed to rain or moisture take the following precautionary measures 1 Use silicone to seal wir...

Страница 11: ...f the EntryProx unit 2 Disconnect the backplate of the EntryProx unit from the controller keypad 3 Remove the wire exits and mounting hole cutouts from the backplate 4 Pull the wires through the backplate 5 Attach the backplate to a wall or glass surface using the mounting screws or the self adhesive fasteners Removing Wiring Exits and Mounting Holes Pulling Wires through the Backplate Wire Exits ...

Страница 12: ...to the following figure for clarification 1 Touch a grounded object BEFORE touching the main circuit board to guard against possible static discharges 2 Remove the main circuit board by pushing outward on the two spring tabs in the direction shown in the following figure 3 Lift the main circuit board 4 Make the wiring connections for the door locking devices the power supply and the alarm inputs a...

Страница 13: ... To wire the EntryProx unit for a secure installation refer to the following two figures as applicable and perform these instructions 1 Touch a grounded object before touching the main circuit board to guard against possible static discharges 2 Remove the main circuit board by pushing outward on the two spring tabs in the direction shown in the figure in Section 4 3 Controller Keypad Wiring 3 Lift...

Страница 14: ... cable is not supplied with the EntryProx unit 9 Make the wiring connections for the Request to Exit switch the door locking devices the power supply and the alarm inputs and outputs See Section 5 Wiring for wiring diagrams 10 Reattach the main circuit board to the controller keypad unit 11 Insert the blank filler piece into the controller keypad unit 12 Attach the controller keypad unit to the mo...

Страница 15: ...ntenna housing s backplate cable holes Mounting the Antenna Backplate 2 Position and secure the antenna backplate to the mounting surface so that the two moisture release holes are on the bottom 3 Cut the plastic connector off the antenna cable assembly 4 Splice in the additional antenna cable Be careful to match the wire colors to the proper pin connectors on the 10 inch antenna cable assembly 5 ...

Страница 16: ... to Exit Label Installation The filler piece replaces the antenna housing on the controller keypad when you use the high security installation 4 6 1 Standard Installation To use the filler piece 1 Insert the filler piece into the opening on the controller keypad 2 Apply the blank label Attaching the Antenna Housing ...

Страница 17: ...alignment pins on the switch activator 3 Apply the Press to Exit label to the filler piece 4 Insert the filler piece into the opening on the controller keypad 5 Refer to the following figure to make the wiring connections to the cable assembly if you are using a door contact 6 Set the internal Request to Exit button ON using programming Command 30 option 7 See Section 10 Programming Commands Fille...

Страница 18: ... drain wires must be grounded at the reader end by connection to P1 Pin 4 DC Power configurations recommended below by connection to P1 Pin 4 DC Power Ground using appropriate wire nuts or crimp fittings Tamper Switch must be installed in one of the configurations recommended below and connected to an intrusion alarm system See the figure in Section 4 9 Wall Mounting for switch and magnet location...

Страница 19: ...cer which is factory installed to the back of the Keypad board at location B as shown in the figure in Section 4 9 Wall Mounting 3 Drill a 3 8 inch hole in the wall behind the magnet location feed the switch wire through the wall and press the switch into place Tamper Switch Installation shown from the back with the base removed Batt Magnet A Magnet B Main Electronics Board Keypad Electronics Boar...

Страница 20: ...ard and its use Connector P5 is not used Pin Locator Diagram The main relay for the door locking device is wired to connector P1 on the EntryProx main circuit board 5 1 Gate Actuator You can make the wire connections for a gate actuator by connecting the Blue C wire and the Green N O wire directly to the input Note If you connect a gate actuator DO NOT connect a power supply to the relay ...

Страница 21: ...d but is held open too long Note The auxiliary relay audible and visual indicators and the door open times can be programmed See Section 10 Programming Commands for more information 5 3 Request to Exit Input When the EntryProx Request to Exit REX input receives a momentary switch closure it engages the main relay for the programmed access time It can be connected to a wall mounted exit button to a...

Страница 22: ...1 is no longer reserved for the Master Code and can be reprogrammed for any User Type If the Master Code Is Lost End Users Contact your dealer A service call is required Dealers Call HID Global Technical Support The proper hex key or security tool will be need to be used at the customer site Consider a Secure Installation For exterior doors or other high risk locations a secure installation is rec...

Страница 23: ... 7 Card PIN Programming Sequences 4 Press to exit program mode You can now program any user type into User Location 1 or you can simply delete it User Location 0 is not an access code it is only used to enter programming mode Although it is not recommended you can also program the same PIN used in User Location 0 as an access code in another location it is the only code not checked for duplication...

Страница 24: ...tion of the Main Relay time Download Log 2 Obsolete No longer supported Note The log is only downloaded and displayed not erased Lockout 3 For this user type the keypad freezes disallowing all other codes plus the door remains in the current state During a lockout state card access does not continue to work If it is locked it remains locked If it is unlocked it remains unlocked until another Locko...

Страница 25: ...Press 99 2468 Press 50 1 2 1111 1111 present card Press Remember to write an entry in your user list User 2 Type 1 PIN 1111 Card 0056 Name John Doe 7 2 Quick Programming PINs or Cards A quick program feature allows user data entry with minimal keystrokes No command number is required This feature programs either a card or a PIN not a combination and it automatically selects a Normal user access ty...

Страница 26: ...m mode 7 4 Programming CARD Only Use To program Card only use with Command 50 simply omit the keypad PIN values from the sequence 1 Place the EntryProx unit in program mode Press 99 Master Code 2 On the EntryProx keypad Press 50 user type user location present card 3 Press to exit program mode 7 5 Programming Code or Card To program a user for either Code OR Card 1 Place the EntryProx unit in prog...

Страница 27: ...rds to be added starting user location card number repeat card number 3 Press to exit program mode 7 7 Batch Load By Presentation Use Command 53 to program a batch of cards into consecutive User Locations by specifying the starting User Location then presenting cards or tags to the reader Use any card format up to 37 bits All cards are programmed alike and users are card only Card enrollment stops...

Страница 28: ...se Command 58 to delete all cards PINs in a block of User Locations The yellow LED will blink rapidly during the deletion process It can take several seconds to delete large blocks of users Note Entering a starting user location or number of locations which exceeds 2000 will generate a programming error To block delete user locations follow this procedure 1 Place the EntryProx unit in program mode...

Страница 29: ...re prevents unauthorized persons from gaining entry by guessing PIN codes or Master Codes When a preset number of invalid entries is exceeded set by using Command 32 option 4 default is 5 the EntryProx will either trigger the Forced Door output or the keypad will be disabled for a user configurable time period select the action using Command 30 option 19 and then set lockout time by using Command ...

Страница 30: ...aster Code 2 Press 40 00000 00000 3 Press to exit program mode 8 4 Erasing Entire Memory Resetting System Defaults Command 46 deletes everything from the EntryProx memory including the user list but not the transaction log and restores the default settings This is used as a last resort if you need to erase a specific user and could not retrieve the Programmed User List After performing this comman...

Страница 31: ...led ON and OFF as desired 1 Place the EntryProx unit in program mode Press 99 Master Code 2 To enable this feature Press 30 1 1 3 To disable this feature Press 30 1 0 4 Press to exit program mode 8 7 Auto Entry Enable This function is not recommended for use as it lowers the overall security of the unit and affects programming sequences ending with the key It is set with the 30 command Set Clear S...

Страница 32: ...2 2 will be used Entering any PIN over 65535 will cause an error condition and no data will be sent Note It may not be possible for some panels to perform Card and Code operation requiring both to gain access because keypad data is sent in a card data format If your panel cannot accept and interpret 26 bit format as PIN data be sure to configure the user at the PC host software by entering the cod...

Страница 33: ...30 14 is enabled this sets the time that a card must be removed from the RF field before it can be re read If option 30 14 is disabled this sets the time between successive readouts used in either standalone or Wiegand mode Option Number Description 0 Audio keypress feature 1 Visual keypress feature 2 Auto entry enable 3 Stand alone Wiegand operation 4 Facility code access 26 bit cards only Note T...

Страница 34: ...nder 44 ttt 0 ttt propped door time to nearest 10 s seconds entered as 10 990 default 30 seconds 15 Set forced door time this sets active time for both the Aux Relay and local sounder 45 ttt 0 ttt forced door time to nearest 10 s seconds entered as 10 990 default 10 seconds 16 Delete memory except user list and restore system defaults also see command 46 40 00000 00000 17 Delete all memory and res...

Страница 35: ...rt user number of users number of users Yellow LED blinks rapidly allow several seconds for large blocks of users Cannot delete master user more than 2000 users or user location greater than 2000 26 Quick Enroll Card User Location present card 27 Download Transaction Log via IR port 70 0 0 Obsolete No longer supported 28 Set transaction log mask set clear event logging 73 event set clear Prevent s...

Страница 36: ...Slow blinking green Obsolete No longer supported Solid green with red flicker Strike toggle is unlocked and used lockout active Red green alternating Awaiting second form of ID during Card AND Code access attempt Red blink User lockout is active and strike locked red LED drops out for 100 ms every second normal users cannot change the state of the relay This also indicates Invalid Pin Lockout Soun...

Страница 37: ...his page Use it as a photocopy master and follow the applicable recommendations Make the number of copies required to record all programmed users Write the specified information in the appropriate spaces Place the users charts in a binder and keep it in a secure location User Location Type Code Card AND OR Last Name First Name Other ...

Страница 38: ...hidglobal com ...

Отзывы: