Electrical Safety Information

Warnings for Safe Use

HiB recommends that all electrical bathroom products must be installed 
in accordance with current building and wiring regulations. 

If in doubt please contact an electrician.
Before drilling ensure that there are no hidden cables or pipes in the wall.

• 

This product is intended for Domestic Use only

• 

Please read the instructions and warnings carefully before installing the product 
and ensure this document is kept with the product for future reference to ensure 
product longevity and in the interest of safety.

• 

If you give the product to another person, please give them this manual as well.

• 

If any modification is made it will invalidate the warranty and may render the 
product unsafe.

• 

This product is IP44 rated and suitable for installation in Zones 2 and Outside Zone 
according to the IEEE regulations.

• 

It is not suitable for use in saunas, steam rooms and shower cubicles.

• 

Appropriate circuit protection should be available for the product.

• 

When drilling use appropriate eye protection.

• 

The use of a Residual Current Device (RCD) is advised for any power tools used 
during the installation of this product.

• 

Take suitable precautions when handling glass.

• 

Do not use if glass is broken or unsafe. 

• 

Beware of hidden cables or pipes. Take care if drilling on tiled surfaces in case the 
drill slips.

• 

Always switch off the electrical supply to the product at the mains during 
installation and maintenance.

• 

It is recommended that this product is installed by a person who is able to meet 
the level of competence required in order to comply with relevant regulations. If 
in doubt consult a qualified tradesperson.

• 

Do not enter IP44 box unless competent and item is isolated from mains.

• 

Do not use if any electrical wires appear damaged or degraded.

• 

This product is designed for installation into a brick or masonry block wall, if 
mounting onto other substrate ensure appropriate fixing and batons (if required) 
are used and the load bearing of the wall is sufficient.

• 

It is recommended that this product is installed by two people.

• 

Avoid leaving excessive standing and surface water on the product for prolonged 
periods of time.

• 

Dispose of packaging in accordance to local authority regulations.

• 

At end of life dispose of item according to local authority regulations.

Содержание Fold 50

Страница 1: ...ough these instructions carefully and refer back to them during installation to ensure that your product is fitted safely and that it retains its high quality finish FOLD Fold 50 Art No 79601000 Fold 60 Art No 79602000 Fold 80 Art No 79603000 FI 01 035 R210701 Ver No 1 0 Oct 2021 ...

Страница 2: ...f a Residual Current Device RCD is advised for any power tools used during the installation of this product Take suitable precautions when handling glass Do not use if glass is broken or unsafe Beware of hidden cables or pipes Take care if drilling on tiled surfaces in case the drill slips Always switch off the electrical supply to the product at the mains during installation and maintenance It is...

Страница 3: ...his product is IP44 rated and is suitable for installation in zones 2 Outside Zone live earth neutral MAINS SUPPLY LUMINAIRE Wiring Diagram Live supply can be Red or Brown Earth supply is Green and Yellow Neutral supply can be Blue or Black Live is Brown Neutral is Blue Fig 1 Zonal Diagram Caution We recommend that you place this mirror on a soft flat surface to ensure no breakages We also recomme...

Страница 4: ...4 What s in the Box Tools Required Pencil Spirit Level Drill Drill bit Screwdriver Fold Mirror Fittings pack ...

Страница 5: ...5 hib co uk Mounting Points Adhesive Pads Figures Fig 2 Mounting points adhesive pads ...

Страница 6: ... surface to avoid cracking NB For plasterboard walls specialist fixings should be purchased available from any DIY or hardware store 5 Screw supplied fixings into wall plugs 6 Ensure the domestic electrical mains supply to which the mirror is being connected is turned off Connect the domestic mains supply to the terminal box according to the wiring diagram see page 3 7 Remove the backing paper fro...

Страница 7: ...en the desired level of illumination is achieved remove your finger NB Once your level is set when you turn the mirror off and then back on again the mirror will revert to the last saved level 2 There are 4 pre set temperatures that cycle through warm daylight and cool colour temperatures 3 To set a customised colour temperature level simply press and hold the CTC switch 4 After 3 seconds the mirr...

Страница 8: ...r duplicated without HiB consent All sizes and measurements are approximate but we do try and make sure they are as accurate as possible In the interest of continuous product development HiB reserves the right to alter specifications as necessary E OE T 44 0 20 8441 0352 F 44 0 20 8441 0219 E sales hib co uk hib co uk Building 3 North London Business Park Oakleigh Road South New Southgate London N...

Отзывы: