4.11. User panel SPACE 3000
Manually controlled cranes are equipped with User Interface SPACE 3000
Functions:
• Stop button (1)
When you push the stop button, all crane movements are
stopped immediately.
• ON/OFF button (2) to switch the safety system On/Off.
• Button (3)
Push the button to operate stabiliser extensions and
legs.
The button is also an OLP release button with the
functions:
Disconnecting the automatic dump function.
OLP release.
• Button (4), to sound the horn, if present.
• Button (5)
Push the button, to switch the manual extensions on/off.
4.11.1. Indicator lights on User Interface SPACE 3000
Power On
(1)
Green light on: The system is on.
Green light flashing: A stop button is depressed
or remote control selected.
Service
(2)
Green light on: Time to service the crane.
Red light on: A non-critical error detected in the
system.
Red light flashing: Critical error is stopping the
crane. Diagnostic required.
Red light dubble flash: CAN Error, crane stops.
SPACE 3000
➀
➁
➂
➃ ➄
The Safety system
HIAB 410K PRO
39