Physical Properties

 

Size: 14cm × 8cm × 3.5cm 

 

 

 

Weight: 360g (with battery) 

 

 

 

Operating Temperature: -20

  ~ +70

  

Storage Temperature: -30

  ~ +80

 

 

 

 

Dustproof and Waterproof 

IP65 

 

 

 

Shock: Anti 1.5 m free fall 

 

 

 

Содержание Qmini H1

Страница 1: ...ial GIS data collector manual 1 Hi Target QminiH Series Industry GIS Data Collector Manual Manual Revision Revised Date Revised Times Specification July 2010 1 QminiH Series Industrial GIS data collector manual 1 0 Version ...

Страница 2: ...iH Series Industrial GIS Data Collector 9 3 3 Reverse of QminiH Series Industrial GIS Data Collector 9 3 4 Interface 10 3 5 Touch Pen Appearance 11 3 6 Battery 11 3 7 Data Cable 12 3 8 Strap 12 Chapter 4 Basic Operation 13 4 1 Introduction 14 4 2 Keyboard 14 4 3 Touch pen 14 4 4 3G card 15 4 5 MicroSD card 16 4 6 Power Supply system 17 4 7 Turn on or turn off QminiH Series industrial GIS data coll...

Страница 3: ...QminiH series industrial GIS data collector manual 3 Chapter 1 Preface Chapter Instruction Instruction Relative Information Technical Support Your Suggestions C H A P T E R 1 ...

Страница 4: ...om 1 2 Relative Information You can get the manual from the following 1 the supplementary CD when purchasing Hi Target QminiH series equipment You can get this manual from folder named Manual 2 Download from Hi Target website Go to Download Section Products Manual GIS products 1 3 Technical Support You can find Technical Support in Hi Target website You can contact our technical center or service ...

Страница 5: ...QminiH series industrial GIS data collector manual 5 Chapter 2 Summary Chapter Introduction Instruction Product Features Usage and Notes C H A P T E R 2 ...

Страница 6: ...econd software package And it can satisfy second development equipment of customer and software provider Tips This manual is for QminiH Series Industry GIS Data Collector product functions will be different according to different model please refer to technical parameters Before using we suggest users firstly to check whether the package box is damaged and then open careful and check whether inner...

Страница 7: ...he Industry GIS Data Collector must be used and stored in the specified temperature More details please refer to Chapter 5 Technical Parameters To ensure the quality of continuous tracking satellites and signals surveying station s top should be in open while there should no any obstacle in space above 15 altitude angle in order to reduce all kinds of electrical interference to the GNSS satellite ...

Страница 8: ...pter 3 QminiH Series Introduction Chapter Introduction Introduction Obverse side of QminiH Series Industrial GIS Data Collector Inverse side of QminiH Series Industrial GIS Data Collector Interface Touch Pen Appearance Battery Data Wire Strap C H A P T E R 3 ...

Страница 9: ...or Touch Screen 3 5 inch upright screen directly touch to operation support Chinese and English input Protective cover wear prevention anti drop anti shock avoid being scratched Key board Direction key enter key escape key power and other function keys Microphone build in microphone can be used for voice information collection on the spot 3 3 Reverse of QminiH Series Industrial GIS Data Collector ...

Страница 10: ... to the performance of the instrument after water happens to go into speaker But please drying the speaker in time 3 4 Interface Figure 3 3 shows the location of interface for QminiH Series Industrial GIS Data Collector Its functions are Charging data transferring SIM installation and SD cards for the Interface Figure 3 3 interface Figure 3 4 interface inner SIM card slot install SIM card MicroSD ...

Страница 11: ... right corner of GIS data collector and the length can be changeable according to the requirements figure 3 6 Figure 3 5 Touch Pen Figure 3 6 Touch Pen 3 6 Battery Figure 3 7 Figure 3 8 Obverse and inverse side of 2000mAh lithium battery Figure 3 7 Obverse of battery Figure 3 8 inverse of battery Tip To protect the environment please do not throw the useless lithium battery away optionally please ...

Страница 12: ...s industrial GIS data collector USD interface connect with USB port of PC to download data Warning To prevent damage the plug store the cable in good place after using without squeezing 3 8 Strap Due to smaller stature of Q mini please put your hand through the strap to prevent falling during the operation work Figure 3 10 Strap USB interface Data collector port ...

Страница 13: ...lector manual 13 Chapter 4 Basic Operation Chapter Introduction Introduction Key board Touch Pen 3G Card Micro SD card Power Supply System Turn on off QminiH Series Industrial GIS Data Collector Data Acquisition Application C H A P T E R 4 ...

Страница 14: ...indicate cancel or quit the current operation Ent Enter F1 Function key Function is defined by the software Please refer to the software manual Power on off key Hold this key one second power on Three seconds or above power off Switch on off backlight after power on Microphone Built in microphone can be used for voice message collecting Tips IF you don t use QminiH series GIS Data Collector in wor...

Страница 15: ...d QminiH 3P 1 Install the 3G card Gently dig the yellow protective cover of interface there is an oblong open mouth as card socket Figure 4 4 installation diagram 2 Figure 4 4 there is a yellow button in the left of 3G card Press it and the 3 G card s cassette will be popup take the card out install the 3G card in the cassette Listen to the sound which plastic spring stuck It shows that installing...

Страница 16: ...is an oblong open mouth as MicroSD card socket Please noted the MicroSD card s metal surface should upward Plug the MicroSD s card to plughole until the MicroSD is completely in the plughole The edge of MicroSD is parallel to the card trough Figure 4 9 MicroSD card 2 Take out the MicroSD card Firstly push the card forward the card will be popup half automatically take MicroSD out Tips MicroSD card...

Страница 17: ...ng the sound of plastic spring sticking It shows installing already Remove 1 See chart 4 11 according to the direction to take out the battery Figure 4 11 remove battery 2 Listen to the sound of gently dig plastic take out the battery QminiH series GIS Data Collector battery and charger s model Power supply mode Name Model 2000mah lithium battery BL 2000A Lithium Battery charger CL 2000A Power sup...

Страница 18: ...when using it first should use the power up then recharge with first three times should charge for 12 hours after third time should charge for 4 hours If the battery often do not use must charge once a month Figure 4 12 charging diagram Figure 4 13 Charging diagram Figure 4 14 finish charging diagram When charging the battery click Start Setup Control Panel power can check the remaining battery re...

Страница 19: ...se change the battery 3 Please stop to use the battery if the using time is obviously short means the battery is aging and please change the battery 4 7 Turn on or turn off QminiH Series industrial GIS data collector Turn on 1 Press 1 second industrial GIS data collector will go into BIOS screen put off the button BIOS will automatically upload to Windows system be patient to wait for about 10 sec...

Страница 20: ...en follow the instruction to finish installing After installing run the Microsoft ActiveSync in Start menu Program Setup Allow to connect by USD in the Connect setup Figure 4 18 Figure 4 18 USB connecting setup 2 Hardware connect Turn on the QminiH series industrial GIS data collector go into Windows system no need to open Application program Connect QminiH series industrial GIS data collector wit...

Страница 21: ...IS data collector see figure 4 20 go into NandFlash related directory to copy the data to your computer Figure4 20 WinCE Asset Browser Screen Tips The collecting data or new installing software must save in NandFlash or MicroSD card otherwise industrial GIS data collector data will be lost after Re start 4 9 Application Function QminiH series industrial GIS data collector adopts PPP technology The...

Страница 22: ...ical Data 5 1 Introduction In this chapter we introduce you the technical parameters of QminiH Series industrial data collector Different models have different product functions When you review this chapter pls review the corresponding technical parameters of the model you purchased 5 2 Technical Parameters C H A P T E R 5 ...

Страница 23: ...TTFF 30 seconds typical Positioning accuracy Single Point Positioning 5 meters SBAS 1 3 meters Communication Interface Built in Bluetooth USB interface WIFI Built in 3G SIM card Built in sealed Micro SD card slot maximum support up to 32GB Power Supply Built in 7 4V Lithium Battery 2000mAh Over 10 hours continuous work Online charging Application Function Built in 3G communication module supportin...

Страница 24: ...industrial GIS data collector manual 24 Physical Properties Size 14cm 8cm 3 5cm Weight 360g with battery Operating Temperature 20 70 Storage Temperature 30 80 Dustproof and Waterproof IP65 Shock Anti 1 5 m free fall ...