![Hi-Force TWS-N Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/hi-force/tws-n-series/tws-n-series_operating-instructions-manual_2128881009.webp)
Operating Instruction Manual:
OM-TWS-N-01
Serial Numbers:
All
9
5.2.1 Connections
(S
ee figure 5.1
)
Connections between couplers are made by simply [1] pressing the male coupler into the female coupler
until [2] the locking collar springs forward and locks the couplers together.
Make certain the spring-loaded retaining rings are fully engaged to prevent the
connectors from disengaging under pressure. A gentle tug on the hose should be
enough to make sure the hose is correctly connected.
5.2.2 Disconnections
(S
ee figure 5.2
)
Always make sure the pump is switched off and pressure has been fully released before
disconnections are made.
To disconnect couplers; [1-1] twist the locking collar on the female coupler in the direction of arrow and
[1-2] pull back toward the female coupler body. [2] With the locking collar retracted, pull the male and female
couplers apart. Fit dust caps after disconnections are made.
Figure 5.1: Hydraulic Connections
Figure 5.2: Hydraulic Disconnections