FRU Replacement Guide
7 Storage Enclosure Basic Field Replaceable Units
88
7.3 Power Cord Replacement Procedure
Required Tools
• None
To replace a power cord, do the following:
Time Estimate
: 7 minutes
1.
Unplug the failed power cord by lifting the
power cord retention bale
and carefully removing the power cord from
the
power supply
.
Figure 61: Replacing the Failed Power Cord
Note:
The power cord is marked in red and the power cord retention bale is marked in blue.
2.
Do the following to remove the failed power cord from the rack:
a) Disconnect the failed power cord from the server.
b) From the Enclosure end, pull the power cord through the rail kit cable guides.
c) Pull the power cord up through the side of the rack rail.
d) Pull the power cord through the top of the rack.
3.
Note:
Ensure the new power cord is installed in the same location as the failed power cord.
Do the following to install the new power cord into the rack:
a) Run the new power cord through the top of the rack.
b) Pull the power cord down through side of the rack rail.
c) From the Enclosure end, pull the power cord through the rail kit cable guides.
d) Connect the power cable to the server.
4.
Pull the power cord through I/O module cable guides.
5.
Plug the power cord into the power supply unit.
6.
To secure the power cord, press the power cord retention bale into the I/O module.