HF-BL200A Low Energy Bluetooh
(
BLE 4.1
)
Module User Manual
Shanghai High Flying Electronics Technology Co., Ltd www.hi-flying.com
- 33
-
"
AT:ERP\r\n
" means invalid command, query failed
4.3.18.
Start Broadcast
Function
:
device start broadcast
Effective time
:
do not execute if under broadcast status and connect status, execute
immediately under other status
Command:
"
AT:ADVSTART
"+ <CR><LF>
Feedback
:
"
AT:OK\r\n
" means command successfully received and start broadcast
"
AT:ADVSTART-
"+<CR><LF> means command successfully received, but status
incorrect
Status: each character indicate a status
‘0’-> CYBLE_CNN_INITIALIZING
‘1’-> CYBLE_CNN_ADVERTISING
‘2’-> CYBLE_CNN_CONNECTED
‘3’-> CYBLE_CNN_DISCONNECTED
‘4’-> CYBLE_CNN_STOPPED
‘5’-> CYBLE_CNN_CONNECTING
"
AT:ERP\r\n
" means invalid command, command failed
4.3.19.
Stop Broadcast
Function
:
stop broadcast
Effective time
:
execute immediately at broadcast status; do not execute if at other status
Command
:
"
AT:ADVSTOP
"+ <CR><LF>
Feedback
:
"
AT:OK\r\n
" means command successfully received and stop broadcast
"
AT:ADVSTOP-
"+<CR><LF> means command successfully received, but status incorrect