background image

INSTRUCTION MANUAL

ENGLISH

www.alcamobil.de

www.alcamobil.de

www.heynermobil.de

Art. 930600

Art. 930800

Art. 931100

Art. 932280

Art. 933080

6 Ampere

max. 60 Ah

12 Volt

8 Ampere

max. 80 Ah

12 Volt

NORMAL / RAPID loading

11 Ampere

max. 120 Ah

12 Volt

NORMAL / RAPID loading

22 Ampere

max. 225 Ah

12 Volt

NORMAL / RAPID l START

30 Ampere

max. 350 Ah

12/24 Volt

NORMAL / RAPID l START

The following contents are not specified to 

your device. They serve for the general 

understanding of all HEYNER battery

chargers. Before starting the charging 

process, make sure that all switches on 

your charger have been set according

to the battery’s specifications.

APPLICATION AREA

Depending on the capacity of your 

HEYNER charger batteries of different 

vehicle categories may be charged. The 

pictograms on the packaging illustrate 

the types of vehicle and battery types 

that are compatible with your charger.

Caution! Only use your charger to charge 

batteries that correspond to the voltage 

and capacity of your charger. Please 

check the technical specifications of 

your battery or contact your battery or 

vehicle manufacturer in case of doubt. 

We assume no liability when charging 

unsuitable batteries.

DESCRIPTION -

ampere | voltage | capacity

•Ampere: Your device and its packaging 

  shows the maximum power that 

  the charger can supply to the battery. 

  This depends on the capacity of the 

  battery you are going to charge. It 

  will decrease during the ch

  process.

•Voltage: The voltage of the battery 

  that you want to charge must 

  correspond with the battery charger’s 

  voltage. Otherwise the charger may not 

  be connected to the battery. 

  Connecting the battery to the charger 

  will cause battery damage if voltages 

  don’t match.

•Capacity: If the Ah rating of the battery 

  falls within the Ah range of the charger, 

  it is possible to fully recharge the 

  empty battery within 8 to 10 hours. If 

  the battery has a higher Ah rating you 

  may charge it anyway but the charging 

  process will take significantly longer.

OPERATION

Caution! After the loading process the 

charger should be divided manually from 

the battery. Please take care of manually

finishing of loading process in time. If 

battery charger is connected too long to 

battery this will lead to unavoidable

defect of battery.

Connecting the charger to the battery 

poles (follow this sequence):

1. Connect the red battery clamp (+) to 

    the positive (+) battery pole.

2. Connect the black battery clamp (-) to 

    the negative (-) battery pole.

3. Use the power cord to connect the 

    charger to a power supply system.

To stop the charging process, consider the 

following steps in order:

1. Unplug the power cord of the charger 

    from the power supply system.

2. Disconnect the black battery clamp (-) 

    from the negative (-) battery pole.

3. Disconnect the red battery clamp (+) 

    from the positive (+) battery pole.

N/R  Switch ( NORMAL/RAPID laden ):

Depending on the type the battery 

charger is equipped with a switch 

NORMAL / RAPID load.  

• When setting the switch to the 

   NORMAL position the loading of the 

   battery will occur with reduced 

   charging power and enlarged charging 

   time. This position is intended for 

   batteries with very low capacities. 

   NORMAL charging will extend battery 

   life. 

•The RAPID position will supply a 

  current up to the maximum current.

START:

The charger can support a weak or 

discharged battery when starting the 

car engine.

• Select the Jump-Start switch position.

• Connect the charger to the battery 

   and mains as described in the User’s 

   Manual.

• We recommend to charge the battery 

   for approx. 10 to 15 minutes before 

   using.

• Keep the charger connected to the 

   battery and to the mains when 

   starting the engine.

• Start the car engine as usual.

• The charger is protected against 

   overload when starting the engine.

   Depending on the current load, an 

   automatic circuit-breaker will 

   interrupt the circuit after approx. 

   10 seconds.

• We recommend to keep the 

   charger connected to the battery for 

   approx. 10 to 15 minutes after 

   starting the engine in order to 

   minimise any voltage spikes.

• Duration of start is automatically to 

   1 to 10 seconds. After completing the 

   JUMP-START process a circuit-breaker 

   cuts out automatically. To perform 

   another start, wait for 5 minutes and 

   reset the circuit-breaker.

Voltage Selector Switch

If your charger does not have a voltage 

selector switch: The charger is only 

supplied with the specified voltage.

Voltage Selector Switch ( 12V / 24V ):

•The 12 Volt / 24 Volt selector switch 

  allows you to charge 12 Volt or 24 Volt

  batteries.

•Please always make sure that the 

  charger voltage and battery voltage 

  match.

•Check the battery voltage before 

  starting the charging process.

•6-cell batteries typically have a nominal 

  voltage of 12 V.

•12-cell batteries typically have a 

  nominal voltage of 24 V.

Ammeter:

The ammeter indicates the battery 

charging current. The charging current 

supplied to the battery depends on the 

battery status. The charging current will 

thus never be constant during the entire

charging process but will decrease 

gradually as the charging level increases. 

When connecting the charger to an 

empty battery, the charging current will be 

high. The ammeter needle will 

indicate a value on the right of the 

gauge.

While charging level increases, the 

charging current will decrease. The 

ammeter needle moves to the left of the 

gauge, indicating that the charging 

process has finished. The battery is fully 

charged.

The ammeter is only an indicator for 

monitoring the charging cycle.

REPLACING THE FUSE

Unplug the power cord from the mains 

and disconnect the battery clamps from 

the battery poles before replacing the 

blade-type fuse. The fuse is placed 

visibly on the front panel. Remove the 

defective fuse (fuse wire broken) and 

replace it with a fuse with the same 

amperage. 

To remove the fuse, insert a screwdriver 

into the slot between the fuse and the

 fuse holder. Use the screwdriver as a 

lever.

Do not apply brute force when replacing 

the fuse!

A defective fuse is excluded from 

warranty!

You can use standard automotive fuses as 

replacement fuses.

WARRANTY TERMS

1. The warranty covers all manufacturing 

    or material faults. The manufacturer 

    offers a free-of-charge replacement 

    (parts or the entire product) for two 

    years from the date of purchase. 

    Only the customer is responsible 

    for the freight charges.  

2. Warranty claims will only be accepted 

    if accompanied by proof of 

    purchase (invoice or coupon).

3. The warranty does not cover 

    necessary repairs as a result of an 

    accident, improper dismantling, 

    damage due to dropping or shocks, 

    improper use, or connection to a 

    higher mains voltage than specified.

4. Under no condition the warranty 

    does include a right of compensation 

    and/or refund.

In case of damage:

Please contact your dealer.

Only for EC-Countries

After the implementation of the Euro-

pean Directive 2002/96/EU in the national 

legal system, the following applies: 

Electrical and electronic devices may not 

be disposed of with domestic waste. 

Consumers are obliged by law to return 

electrical and electronic devices at the end 

of their service lives to the public

collecting points set up for this purpose or 

point of sale. Details to this are defined by 

the national law of the respective country. 

This symbol on the product, the

instruction manual or the package 

indicates that a product is subject to these 

regulations. By recycling, reusing the 

materials or other forms of utilising old

devices, you are making an important 

contribution to protecting our environ-

ment.

Содержание AkkuEnergy 930600

Страница 1: ...Instruction PRO CHARGER AkkuEnergy P R O F E S S I O N A L A U T O B A T T E R Y PRO CHARGER AkkuEnergy P R O F E S S I O N A L A U T O B A T T E R Y Art 930600 Art 930800 Art 931100 Art 932280 Art 9...

Страница 2: ...liable charging of all lead acid batteries incl AGM Mobility 100 guaranteed even at extreme temperatures up to 40 C Universal fitting cable clamps Extra large robust metal quality with isolation Certi...

Страница 3: ...werden stoppen sie den Ladeprozess und lassen Sie die Batterie vom Fachmann berpr fen Keine nicht wiederaufladbaren Prim rbatterien laden Die Batterie nicht der Sonne aussetzen Bei Nutzung des Ladeger...

Страница 4: ...adeger t an die Batterie abgeben kann Dieser ist abh ngig von der aktuellen Kapazit t der Batterie Er wird mit fortlaufendem Ladevorgang abnehmen Spannung Die Spannung der zu ladenden Batterie muss mi...

Страница 5: ...ung immer weiter abnehmen Bei Anschluss des Ladeger tes an eine leere Batterie liefert das Ladeger t einen hohen Ladestrom Der Zeiger des Ampere meters steht im rechten Bereich der Anzeigeskala Mit fo...

Страница 6: ...rging process stop the process and let the battery check by an expert Do not recharge any non rechargeable primary batteries Do not expose the battery to direct sunlight When using the charger do not...

Страница 7: ...attery that you want to charge must correspond with the battery charger s voltage Otherwise the charger may not be connected to the battery Connecting the battery to the charger will cause battery dam...

Страница 8: ...el increases the charging current will decrease The ammeter needle moves to the left of the gauge indicating that the charging process has finished The battery is fully charged The ammeter is only an...

Страница 9: ...www alcamobil de www alcamobil de EX 1 2 3 II...

Страница 10: ...mobil de Art 930600 Art 930800 Art 931100 Art 932280 Art 933080 6 A 60 A 12 8 A 80 A 12 NORMAL RAPID 11 A 120 A 12 NORMAL RAPID 22 A 225 A 12 NORMAL RAPID START 30 A 350 A 12 NORMAL RAPID START HEYNER...

Страница 11: ...www alcamobil de www alcamobil de 2 3 N R NORMAL RAPID NORMAL RAPID NORMAL RAPID 10 15 10 10 15 1 10 5 12 24 12 24 12 24 6 12 12 24 1 2 3 4 2002 96 EC...

Страница 12: ...t mit der den folgenden Norm en oder normativen Dokument en bereinstimmt to which this declaration relates is in conformity with the following standard s or other normative document s Safety EN 60335...

Отзывы: