Heylo TurboVent 2000 Скачать руководство пользователя страница 10

 

10 

EN 

EC  Declaration  of Conformity, IIA

 

In conformity with EC Machine Directive 89 / 392/ EC, 

modified by Directive 91 / 368 / EC 

 

For unit series:   

 

Air mover / TurboVent 

Type: 

 

 

 

TV 2000 / TV 2000 PRO 

 
HEYLO GmbH of Im Finigen 9, D-28832 Achim, Germany, declares that, if they are fitted, maintained and used in 
conformity with the operating instructions and the generally accepted engineering standards, the machines 
mentioned are in keeping with the fundamental safety and health requirements of the “Machine Ordinance” as 
well as with the regulations and standards mentioned hereinafter. 
 

Applicable EC directives: 

EN 600335-1:2002 + A2:2006 

 

Safety of machines (machine ordinance) 

EN 60335-2-40:2003 + A11:2004   

Safety of machines (machine ordinance) 

EN 61000-6-3:2007 

Electro-Magnetic Compatibility (EMC). Part 6-3 

EN 61000-6-1:2007  

Electro-Magnetic Compatibility (EMC). Part 6-1 

EN 61000-6-2:2006 

Electro-Magnetic Compatibility (EMC).  

EN 61000-6-3:2008 

 

 

Electro-Magnetic Compatibility (EMC).  

EN 300 220-3 v1.1.1 

 

 

Electro-Magnetic Compatibility (EMC). 

EN301 489-3 v1.4.1 

 

 

Electro-Magnetic Compatibility (EMC). 

 
These products meet the requirements in conformity with the Directive on Electromagnetic Compatibility 
2004/108/EC and its modifications, the Directive 2006/95/EC and the Low-Voltage Directive and its modifications. 
The devices are manufactured according to RoHS. 
 
The devices are type-tested in conformity with German standard DIN VDE 0700,  
part 1 and part 30 EN 60335-1 and EN 60335-2-30 and bear a CE mark. 

 
 
 

 

 

Achim, 28th February 2014 

 

 

 

 

…………………….…….…………….. 
Dr. Thomas Wittleder 
   - Managing Director -  

---------------------------------------------------------------------------------------------------------------------------------------- 
 

Table of contents 

 

 

 

 

 

 

 

 

…… 

 

 

1. General aspects ................................................................................................................................ 11

 

2. Use of air movers / air blowers .......................................................................................................... 11

 

3. Setting up the unit .............................................................................................................................. 11

 

4. Humidity control ................................................................................................................................. 11

 

5. Operation of the unit .......................................................................................................................... 12

 

6. Maintenance / repair .......................................................................................................................... 13

 

7. Technical data ................................................................................................................................... 14

 

8. Fault finding and correction ............................................................................................................... 14

 

9. List of spare parts .............................................................................................................................. 15

 

10. Wiring diagram ................................................................................................................................ 16

 

a) TV 2000 ........................................................................................................................................ 16

 

b) TV 2000 PRO ............................................................................................................................... 17

 

 

 

 

Содержание TurboVent 2000

Страница 1: ...urboVent 2000 VENTILATOR BEDIENUNGSANLEITUNG USER MANUAL DE Ventilator EN Air mover DER EXPERTE F R PROFIS www heylo de Stand 09 2014 Art Nr 1 110 817 TurboVent 2000 Art Nr 1 110 818 TurboVent 2000 PR...

Страница 2: ...keit EMC Part 6 1 EN 61000 6 2 2006 Elektromagnetische Vertr glichkeit EMC EN 61000 6 3 2008 Elektromagnetische Vertr glichkeit EMC EN 300 220 3 v1 1 1 Elektromagnetische Vertr glichkeit ERM EN301 489...

Страница 3: ...en lassen oder werfen da es sonst zu Besch digungen von Bauteilen oder der Verdrahtung kommen kann Auf einer festen Fl che arbeiten Das Ger t immer auf einer festen ebenen Fl che aufstellen W hrend de...

Страница 4: ...rocken k nnen Fenster oder T ren einen Spalt ge ffnet werden 5 Bedienung des Ger tes Das Ger t an eine geerdete Steckdose anschlie en Den Schalter auf Betrieb ON stellen Den korrekten Betrieb berpr fe...

Страница 5: ...Glanz mit Vinylreiniger und politur z B HEYLO POWER CLEAN Kunststoffreiniger wiederherstellen berpr fung der Au enseite berpr fen Sie die u eren Bauteile und achten Sie darauf dass sie richtig instal...

Страница 6: ...r fen Schalter einschalten Grund f r die Blockierung entfernen Maschine abschalten und abk hlen lassen dann Blockierung entfernen Ersatzschalter vom H ndler oder von HEYLO anfordern Verdrahtung berpr...

Страница 7: ...PM DE03 01755 01 Griff DE09 01508 Schutzgitter Ansaugseite 1400320 Motorkondensator DE02 01711 Ein und Ausschalter DE09 01510 Schutzgitter Ausblasseite DE04 00048 Anschlusskabel DE03 00131 Gummifu 144...

Страница 8: ...8 DE 10 Schaltplan a TV 2000...

Страница 9: ...9 DE Schaltplan b TV 2000 PRO...

Страница 10: ...Compatibility EMC Part 6 1 EN 61000 6 2 2006 Electro Magnetic Compatibility EMC EN 61000 6 3 2008 Electro Magnetic Compatibility EMC EN 300 220 3 v1 1 1 Electro Magnetic Compatibility EMC EN301 489 3...

Страница 11: ...as this may cause damage to the unit or wiring Operate on solid surface Always set up the unit on a solid and plane surface Secure during transport When transporting units in vehicles secure against...

Страница 12: ...t 5 Operation of the unit Connect the unit to an earthed socket Set the switch to ON Check correct operation before leaving the unit unattended Do no move or carry air mover during operation For the r...

Страница 13: ...HEYLO POWER Clean plastic cleaner to restore the original glossiness Checking the outer side Check the external components and make sure that have been installed correctly Listen for unusual noises M...

Страница 14: ...he unit check the fuse Switch the unit on Remove the reason for the blockage Switch the unit off and let it cool down then remove blockage Order replacement switch from the dealer or HEYLO Check wirin...

Страница 15: ...55 01 Handle DE09 01508 Protective grille suction side 1400320 Motor capacitor DE02 01711 On and off switch DE09 01510 Protective grille exhaust side DE04 00048 Connection cable DE03 00131 Rubber foot...

Страница 16: ...16 EN 10 Wiring diagram a TV 2000...

Страница 17: ...17 EN Wiring diagram b TV 2000 PRO...

Страница 18: ...und in our online shop at www heylo shop de Trocknung Drying Ventilation Ventilation Luftreinigung Air cleaning Messtechnik Measurement Technology Beheizung Heating Seminare Seminars MOBILE LUFTSYSTEM...