21
manufacturer or an authorised
technician.
Avoid contact with the refrigerant.
When handling the refrigerant,
strictly adhere to the applicable
safety regulations.
WARNING! Risk of electric shock
When carrying out work on electrically
powered components, or if such
components come into contact with
water, there is a risk of serious or
even fatal injury from electric shock.
All work on the electrical equip-
ment must be carried out by quali-
fied electricians.
Take suitable measures to prevent
electrically powered components
coming into contact with water.
Before moving the device to a
different location, disconnect the
mains plug and empty the con-
densate tank.
WARNING! Risk of infection
The condensate may be contaminat-
ed with pathogens.
Never drink the condensate.
Regularly pump off the conden-
sate. Avoid leaving condensate in
the collecting vessel or in the con-
densate drain hose for a longer
period of time.
Operating conditions
The device is intended for mobile or
stationary use indoors, on construc-
tion sites, as well as in garages and
storage rooms. The device operates
efficiently:
■
At temperatures b5 °C
and +35 °C and at relative humid-
ity levels between 40% and
100%.
Ideal conditions: room tempera-
ture between 20 °C and 27 °C.
■
In closed rooms where there is as
little air exchange as possible.
■
When placed at close as possible
to the centre of the room.
■
When the dry air discharged by
the device is directed towards the
humid part of the room.
Do not use the device under the fol-
lowing ambient conditions:
■
Rooms with a potentially explo-
sive atmosphere, or an atmos-
phere containing sulphur or salt.
■
Atmospheres with high solvent or
dust concentration.
7 Transport and
installation
Transport
WARNING! Risk of injury from
device toppling over
Transport the device in an upright
position and secure it against tip-
ping or slipping.
Place the device on a level, firm
surface.
WARNING! Risk of injury during
machine transport
To transport the device, use the
handle and the castors/transport
wheels.
For heavy loads, work in teams of
two and use suitable lifting gear.
Procedure
1. Before transporting the device,
empty the condensate tank.
Содержание 1110570