Hewi ES5403 Скачать руководство пользователя страница 7

HEWI

 

   Installation-instruction

M1000_123_ES5403_DE-Vers-001.pdf

M1000.123

Page 7 of 8

HEWI P.O. Box 1260 D-34442 Bad Arolsen

Data sheet

General

Product description

Wallreader basis-unit ES5403

Casing

Length x width x height

70 x 70 x 44 mm

Material

synthetic

Installation depth

min. 40 mm

Installation diameter

50 mm

Power supply /
connections

Current

Input

12 - 37 V DC unregulated
23 - 27 V AC

4 - 37 V DC / 4 - 27 V AC 30 - 100 Hz +/- 10%

Current consumption

max. 500 mA without load (with 6 reader modules )

Switching capacity

Relay Closer/NO max. 40 V AC/DC / 1,6 A
Relasi Opener/NC max. 40 V AC/DC / 0,25 A
Relais Opener/NC (Alarm) max.  40 V AC/DC / 0,25 A

Connection cable

I-Y(ST)Y 8 x 2 x 0,8

Power adaptor

Depending on number of wallreaders.

Specific data

Operating temperature

-20 bis +70 °C

Storage temperature

-40 bis +85 °C

Humidity

Max. 95% not condensing

Outputs

3 Relays (Photomos-Relays) 1 x NO (Closer), 2 x NC (Opener)

Data interfaces

RS485 e.g. for operating a programmable logic controller
RS485 for communication with up to 8 reading-modules ES5401
/ ES5402 / ES5404

Communication with
programming device

Inducticve coupling.

Connection configuration

See figure

Memory size

25.000 or 60.000 identifiers (after consultation of HEWI)

Time zones

2 per identifier

Special time zones

20, programmable with administration software HEWIKey5

Tests

CE-test

Basic technical standard EN 5002 1081

Содержание ES5403

Страница 1: ...be seperated from the basis unit Please use the ES5403 in the secured inside area in combination with the ES5401 ES5402 ES5404 in the unsecured outside area b Environmental requirements Combined with...

Страница 2: ...data connection uses a RS485 Bus that means the connection cable is wired from the basis unit compact wallreader to the first reading module and from there to the second reading module an so on Umbrel...

Страница 3: ...ished please programm the wallreader instantaneously using the HEWIKey5 Administration software the programming device and the programming key card In doubt please contact the HEWI Servicecenter locki...

Страница 4: ...standard installation 1 Lock the basis unit ES5403 in backside of the cover ES5410 2 The sub finery socket depth min 40 mm should be mounted smooth to the wall 3 Install all neccessary connections po...

Страница 5: ...ews Turn the screws carefully so that the circuit board doesn t become distorted Alternative use 4 screws at the outside fitting points 6 Plug the cover onto the wallreader After switching on the powe...

Страница 6: ...the event protocolls which can be evaluated using the programming device and the HEWIKey Software Coceivably you ll find indications of a wrong programming of the locking system which can be critical...

Страница 7: ...0 25 A Relais Opener NC Alarm max 40 V AC DC 0 25 A Connection cable I Y ST Y 8 x 2 x 0 8 Power adaptor Depending on number of wallreaders Specific data Operating temperature 20 bis 70 C Storage temp...

Страница 8: ...1 VCC onyl for seperated reader module J2 2 closer 1 NO J3 2 RS485 A onyl for seperated reader module J2 3 opener 1 NC J3 3 RS485 B onyl for seperated reader module J2 4 opener 1 NC J3 4 GND onyl for...