Under  the  Clean  Air  Act  local  authorities  may 
declare  the  whole  or  part  of  the  district  of  the 
authority to be a smoke control area. It is an of-
fence to emit smoke from a chimney of a buil-
ding,  from  a  furnace  or  from  any  fixed  boiler  if 
located  in  a  designated  smoke  control  area.  It 
is  also  an  offence  to  acquire  an”  unauthorized 
fuel” for use within a smoke control area unless 
it is used in an” exempt” appliance (” exempted” 
from  the  controls  which  generally  apply  in  the 
smoke control area).

In England appliances are exempted by publica-
tion on a list by the Secretary of State in accor-
dance  with  changes  made  to  sections  20  and 
21  of  the  Clean  Air  Act  1993  by  section  15  of 
the Deregulation Act 2015. Similarly, in Scotland 
appliances are exempted by publication on a list 
by Scottish Ministers under section 50 of the Re-

gulatory  Reform  (Scotland)  Act  2014.  In  Wales 
and  Northern  Ireland  these  are  authorized  by 
regulations made by Welsh Ministers and by the 
Department of the Environment respectively. 

Further  information  on  the  requirements  of  the 
Clean Air Act can be found here: 
https://www.gov.uk/smoke- control-area-rules 

Your  local  authority  is  responsible  for  imple-
menting the Clean Air Act 1993 including desig-
nation and supervision of smoke control areas 
and  you  can  contact  them  for  details  of  Clean 
Air Act requirements

The  Prestige  with  and  without  side  windows 
have all been recommended as suitable for use 
in smoke control areas when burning dry wood 
logs.

5. Appendix A

The Clean Air Act 1993 and Smoke Control Areas.

Содержание Prestige A

Страница 1: ...UCTIONS PRESTIGE INSERT STOVE THE PRESTIGE PRESTIGE SCA SERIES IS EXEMPT FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD DANISH DESIGN DANISH QUALITY DANISH PRODUCTION www heta dk EN Prestige A P...

Страница 2: ...Dust 27 mg Nm3 Dust NS3058 3059 2 15 g kg OGC CEN TS 15883 81 mgC Nm3 at 13 O2 9 Fire safety Reaction to fire A1 Test of fire safety in connection with the burning of wood Approved Distance to combust...

Страница 3: ...ail heta heta dk Copyright 2014 Heta is a registered trademark of Heta A S 28 11 2019 0037 1485 Version 1 4 Printed in Denmark Subject to printing errors and changes Operating Instructions Contents Be...

Страница 4: ...dealers Neverthe less when in transport or handling damage of the often heavy stoves can occur It is important that upon receipt check your Heta product completely and report any damage or defects to...

Страница 5: ...el F lg fabrikantens brugervejledning Indsatsen m lslu es r ggas samleledning Tr 8 kW 312 C 0 085 27 mg Nm 2 15 g kg 79 109 mg Nm DOP Pres ge Indsats 2237 2016 Pres ge Indsats Produkt beskrivelse 1063...

Страница 6: ...A permanent amount of air will therefore enter the firebox to feed the fire producing negligible amounts of smoke and unburnt hydrocarbons The applian ces will only be considered as an exempt appli a...

Страница 7: ...minutes Once the fuel is Ignited Close the door and regulate the air back to ope rating air When the fire is well established you can now regulate the operating air to the desired combustion level No...

Страница 8: ...provide clean burning beautiful flame picture as well as achieving the rated efficiency There is a risk of smoke escaping into the room if the door is opened during vigorous firing or if there is a l...

Страница 9: ...eating value per kg which is about 5 27 kW hour for absolute dry wood Wood with a moistness of 18 has a efficiency of about 4 18 kW hour per kg and one litre heating oil contains about 10 kW hour CO2...

Страница 10: ...chamber is visible Too rapid combustion Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe i...

Страница 11: ...Qualified Technicia Maintenance Period Before Autum Daily 2 3 days 30 days 60 90 days 1st Year 2st Year Cleaning the chimney see Chimney C Cleaning the chimney and stove C C Cleaning the stoves fireb...

Страница 12: ...fore replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Removal sequence of stones Replace in reverse order Starting with Fig 8 7 1 3 4...

Страница 13: ...was carried out with the combustion air 40 1 19 Guarantee Heta wood stoves subjected to a strict quality control during production and before delivery to the dealer Therefore the stoves guarantee is F...

Страница 14: ...restige C 8 9 10 11 8 Prestige BR Prestige BL Prestige C 12 13 14 Prestige C 15 Prestige BR Prestige BL 16 Prestige A 17 18 19 20 21 23 24 25 26 27 28 x 2 29 30 31 32 33 34 35 Prestige BR Prestige BL...

Страница 15: ...m 22 0030 2609 Hinge 2 23 0008 9082 Cylinder pin 6x35 2 24 4013 0004 Start up air return spring 1 25 1513 0124 Closure mirrored 1 Pos No Name Qty 26 1513 0123 Closing System 1 27 1505 0084 Left hinge...

Страница 16: ...2 Installation instructions 17 2 1 Distance requirements 17 2 2 Floor 17 2 3 Chimney connection 17 2 4 Combustion air 18 2 5 Stovedrawings measurments 19 2 6 Fitting the flue collar 20 2 7 Clearances...

Страница 17: ...tention to the distance to flammable floor 330 mm which is also applicable although there is a steel glass plate on the floor If the floor is made of for ex concrete tile or similar there may not be c...

Страница 18: ...mm2 per kW output will be required 4 5 kW x 550 mm 2475 mm2 un less the stove is connected to an outside fresh air supply Connection to a brick chimney Brick a thimble into the chimney and seat the fl...

Страница 19: ...surments 752 501 463 464 294 705 169 731 501 505 294 186 708 464 480 731 501 480 464 294 186 708 505 501 710 480 464 294 186 505 Measurment Prestige A Measurment Prestige BR Measurment Prestige BL Mea...

Страница 20: ...sert without side windows 400 mm 7 Min 130 mm from top edge of convection outlet to a combustible material 8 Not combustible 12 5 0 36 W m K 9 Floor board Min 150 mm to combustible flooring to the sid...

Страница 21: ...BR BL 130 400 550 135 C N A N A 550 135 The dimensions are the minimum dimensions unless otherwise stated insulated flue pipe Applies to both right and left sides 5 6 2 1 9 10 3 7 Min 1080 cm2 Min 58...

Страница 22: ...ulite must be removed from the stove before mounting in the wall See on page 12 It is optional whether you want to mount the support rod1516 0007 See Fig 5 7 The cor ner must be removed if used suppor...

Страница 23: ...Prestige C Prestige A Prestige A 10 11 12 13 23 6 7 8 9 Prestige BR Prestige BL Prestige BR Prestige BL Prestige C Prestige BR BL C Prestige BR Prestige BL Prestige BR Prestige BL...

Страница 24: ...14 15 16 5 x M4x8 24 Prestige C Prestige C Prestige C 3 Connecting external air supply from below 2 x4 1 3 x4...

Страница 25: ...4 5 6 7 8 25 x4...

Страница 26: ...hinged door Model Prestige BR 8120 0100 with side window in the right side Left hinged door or right hinged door The Scan Line Prestige models Model Prestige BL 8120 0200 with side window in the left...

Страница 27: ...ction 15 of the Deregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Re gulatory Reform Scotland Act 2014 In Wales...

Страница 28: ...28...

Отзывы: