dry  wood  in  your  stove.  Never  use  your  stove 
to  burn  driftwood,  as  this  may  contain  a  lot  of 
salt which can damage both the stove and the 
chimney. Similarly, you must not fire your stove
with refuse, painted wood, pressure-impregna-
ted wood or chipboard, as these materials can 
emit poisonous fumes and smoke. 

Correct  firing  using  well  seasoned  wood  pro-
vides  optimal  heat  output  and  maximum  effi-
ciency. At the same time, correct firing prevents 
environmental  damage  in  the  form  of  smoke 
emissions and reduces the risk of chimney fires. 
If the wood is damp and inadequately seasoned, 
a large proportion of the energy in the fuel will 
be  used  to  vaporize  the  water,  and  this  will  all 
disappear up the chimney. Thus, it is important 
to use dry, well seasoned wood, i.e. wood with a 
moisture content of less than 20 %. Achieve this 
by storing the wood for 1–2 years before use.

Pieces of firewood with a diameter of more than
10 cm should be split before before storing. The
pieces of firewood should be of an appropriate
length (approx. 19-25 cm) so that they can lie
flat on the bed of embers. 

If  you  store  your  wood  outdoors,  it  is  best  to 
cover it.

Examples of fuel values

for  different  woods  and  their  typical  densities 
per cubic meter, specified for 100% wood with 
a moisture content of 18%.

Wood

kg/m

3

Wood

kg/m

3

Beech

710

Willow

560

Oak

700

Alder

540

Ash

700

Scotch pine

520

Elm

690

Larch

520

Maple

660

Lime

510

Birch

620

Spruce

450

Mountain pine

600

Poplar

450

It is advised not to use oil-containing woods 
like teak tree and mahogany, as this can cau-
se damage to the glass.

Heating value in wood

You have to use about 2.4 kg normal wood to 
replace  one  litre  of  heating  oil.  All  woods  have 
almost the same heating value per kg, which is 
about 5.27 kW/hour for absolute dry wood.
Wood with a moistness of 18% has a efficiency

of  about  4.18  kW  /  hour  per  kg,  and  one  litre 
heating oil contains about 10 kW / hour.

CO

2

 release

At  combustion  1000  litres  of  heating  oil  forms 
3.171 tons CO

2

. As wood is a CO

2

 neutral heat/

energy source, you save the environment about
1.3 kg CO

2

 every time you have used 1 kg nor-

mal wood.

1.11 Operational problems

The  chimney  must  be  swept  at  least  once  a 
year, we recommend the use of a NACS (natio-
nal  association  of  chimney  sweeps)  registered 
chimney sweep.
In the event of smoke or malodorous fumes are
being  produced,  you  must  first  check  to  see 
whether the chimney is blocked.
The  chimney  must,  of  course,  always  provide 
the minimum draft necessary to ensure that it is 
possible to regulate the fire. Please note, how-
ever,  that  chimney  draft  is  dependent  on  the 
weather conditions. In high winds, the draft can 
become so powerful that it may be necessary to 
fit a damper in the flue gas pipe to regulate the 
draft.
When  cleaning  the  chimney,  soot  and  other 
deposits  may  come  to  fall  on  the  baffle  plate, 
remove  and  clean  it.  In  cases  where  the  wood 
burns too quickly, this may be due to excessive 
chimney draft. You should also check to make 
sure that the door seal and ash pan seal is intact 
and correctly fitting. 
If the stove it generating too little heat, this may
be because you are firing with wet wood. In this
case, much of the heating energy is used to dry
the  wood,  resulting  in  poor  efficiency,  poten-
tially damaging the vermiculite and an increased 
risk of soot deposits in the chimney.

1.12 Chimney fire

In case of a chimney fire, which often results from 
incorrect  operation/maintenance  or  prolonged 
use  of  damp  wood,  close  the  door  and  the  air 
supply completely, to help slow/smother the fire.
Call the fire department.

The stove and chiminey must be inspected be-
fore use again.

Содержание Prestige A

Страница 1: ...UCTIONS PRESTIGE INSERT STOVE THE PRESTIGE PRESTIGE SCA SERIES IS EXEMPT FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD DANISH DESIGN DANISH QUALITY DANISH PRODUCTION www heta dk EN Prestige A P...

Страница 2: ...Dust 27 mg Nm3 Dust NS3058 3059 2 15 g kg OGC CEN TS 15883 81 mgC Nm3 at 13 O2 9 Fire safety Reaction to fire A1 Test of fire safety in connection with the burning of wood Approved Distance to combust...

Страница 3: ...ail heta heta dk Copyright 2014 Heta is a registered trademark of Heta A S 28 11 2019 0037 1485 Version 1 4 Printed in Denmark Subject to printing errors and changes Operating Instructions Contents Be...

Страница 4: ...dealers Neverthe less when in transport or handling damage of the often heavy stoves can occur It is important that upon receipt check your Heta product completely and report any damage or defects to...

Страница 5: ...el F lg fabrikantens brugervejledning Indsatsen m lslu es r ggas samleledning Tr 8 kW 312 C 0 085 27 mg Nm 2 15 g kg 79 109 mg Nm DOP Pres ge Indsats 2237 2016 Pres ge Indsats Produkt beskrivelse 1063...

Страница 6: ...A permanent amount of air will therefore enter the firebox to feed the fire producing negligible amounts of smoke and unburnt hydrocarbons The applian ces will only be considered as an exempt appli a...

Страница 7: ...minutes Once the fuel is Ignited Close the door and regulate the air back to ope rating air When the fire is well established you can now regulate the operating air to the desired combustion level No...

Страница 8: ...provide clean burning beautiful flame picture as well as achieving the rated efficiency There is a risk of smoke escaping into the room if the door is opened during vigorous firing or if there is a l...

Страница 9: ...eating value per kg which is about 5 27 kW hour for absolute dry wood Wood with a moistness of 18 has a efficiency of about 4 18 kW hour per kg and one litre heating oil contains about 10 kW hour CO2...

Страница 10: ...chamber is visible Too rapid combustion Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe i...

Страница 11: ...Qualified Technicia Maintenance Period Before Autum Daily 2 3 days 30 days 60 90 days 1st Year 2st Year Cleaning the chimney see Chimney C Cleaning the chimney and stove C C Cleaning the stoves fireb...

Страница 12: ...fore replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Removal sequence of stones Replace in reverse order Starting with Fig 8 7 1 3 4...

Страница 13: ...was carried out with the combustion air 40 1 19 Guarantee Heta wood stoves subjected to a strict quality control during production and before delivery to the dealer Therefore the stoves guarantee is F...

Страница 14: ...restige C 8 9 10 11 8 Prestige BR Prestige BL Prestige C 12 13 14 Prestige C 15 Prestige BR Prestige BL 16 Prestige A 17 18 19 20 21 23 24 25 26 27 28 x 2 29 30 31 32 33 34 35 Prestige BR Prestige BL...

Страница 15: ...m 22 0030 2609 Hinge 2 23 0008 9082 Cylinder pin 6x35 2 24 4013 0004 Start up air return spring 1 25 1513 0124 Closure mirrored 1 Pos No Name Qty 26 1513 0123 Closing System 1 27 1505 0084 Left hinge...

Страница 16: ...2 Installation instructions 17 2 1 Distance requirements 17 2 2 Floor 17 2 3 Chimney connection 17 2 4 Combustion air 18 2 5 Stovedrawings measurments 19 2 6 Fitting the flue collar 20 2 7 Clearances...

Страница 17: ...tention to the distance to flammable floor 330 mm which is also applicable although there is a steel glass plate on the floor If the floor is made of for ex concrete tile or similar there may not be c...

Страница 18: ...mm2 per kW output will be required 4 5 kW x 550 mm 2475 mm2 un less the stove is connected to an outside fresh air supply Connection to a brick chimney Brick a thimble into the chimney and seat the fl...

Страница 19: ...surments 752 501 463 464 294 705 169 731 501 505 294 186 708 464 480 731 501 480 464 294 186 708 505 501 710 480 464 294 186 505 Measurment Prestige A Measurment Prestige BR Measurment Prestige BL Mea...

Страница 20: ...sert without side windows 400 mm 7 Min 130 mm from top edge of convection outlet to a combustible material 8 Not combustible 12 5 0 36 W m K 9 Floor board Min 150 mm to combustible flooring to the sid...

Страница 21: ...BR BL 130 400 550 135 C N A N A 550 135 The dimensions are the minimum dimensions unless otherwise stated insulated flue pipe Applies to both right and left sides 5 6 2 1 9 10 3 7 Min 1080 cm2 Min 58...

Страница 22: ...ulite must be removed from the stove before mounting in the wall See on page 12 It is optional whether you want to mount the support rod1516 0007 See Fig 5 7 The cor ner must be removed if used suppor...

Страница 23: ...Prestige C Prestige A Prestige A 10 11 12 13 23 6 7 8 9 Prestige BR Prestige BL Prestige BR Prestige BL Prestige C Prestige BR BL C Prestige BR Prestige BL Prestige BR Prestige BL...

Страница 24: ...14 15 16 5 x M4x8 24 Prestige C Prestige C Prestige C 3 Connecting external air supply from below 2 x4 1 3 x4...

Страница 25: ...4 5 6 7 8 25 x4...

Страница 26: ...hinged door Model Prestige BR 8120 0100 with side window in the right side Left hinged door or right hinged door The Scan Line Prestige models Model Prestige BL 8120 0200 with side window in the left...

Страница 27: ...ction 15 of the Deregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Re gulatory Reform Scotland Act 2014 In Wales...

Страница 28: ...28...

Отзывы: