Heta Prestige A Скачать руководство пользователя страница 17

17

2. Installation instructions

The  stove  installation  must  be  in  accordance 
with national, European and possibly local regu-
lations.  You  must  follow  local  regulations  with 
regard to installation of chimney and connection 
to  the  chimney.  We  recommend  that  you  let  a 
professional Heta dealer install the stove. Alter-
natively, you can ask the local chimney sweep 
before installation. Be aware that it is always the 
owner himself who has responsibility for ensu-
ring that applicable rules are complied with.

A modern stove places heavy demands on the 
chimney  due  to  the  high  efficiency.  It  may  be 
necessary  to  enhance  or  even  replace  an  old 
chimney.

Remember

1.  Always ensure free access to any cleaning   

doors in a chimney.

2.  Always ensure ample fresh air to the room.
3.  Exhaust/extraction fans in the house can re-

duce or create negative draft in the chimney. 
Reduced draft can lead to the stove having 
adverse  combustion  properties.  It  may  result 
in smoke coming out of the stove when the 
door  is  open.  A  negative  draft  due  to  an 
exhaust/extraction fan can cause the chim-
ney to work in reverse, drawing smoke into 
the house because of the fan.

4.  Any air vents must not be covered.

2.1 Distance Provisions

There is a difference between installation next to 
flammable wall or non-flammable wall. If the wall 
is made of non-flammable material, the stove in 
principle may be placed flush against it.

Inserts are generally only intended for installing 
in existing open fireplaces or in a wall built of non-
combustible material. There must be adequate 
space  between  the  wall  and  the  convection 
case. This is to avoid damage to the masonry/
wall when the stove expands when in use.

Minimum distances to combustible material found 
on the table on page 18-19, the data plate, as 
well  as  drawings.  Pay  special  attention  to  the 
distance to flammable floor (330 mm), which is 
also  applicable,  although  there  is  a  steel/glass 
plate on the floor. If the floor is made of, for ex. 
concrete, tile or similar, there may not be com-
bustible materials for at least a depth of 330

mm, valid from the bottom edge of the door on 
the insert.

Distances for installation see page 18.

2.2 Floor

You must ensure that the floor can support the 
weight  of  the  stove  and  a  top-mounted  steel 
chimney.

In  front  of  the  fireplace  insert,  the  substrate 
must  consist  of  non-combustible  material,  for 
ex. Steel/glass plate, stone or tile floor. The size 
of the non-combustible surface must follow the 
applicable  national  and  local  regulations.  Pro-
tecting your floor from embers that may fall out 
of the oven.

Distances see data table page 20-21. 
Distance from flammable floor:  330 mm.

Pay special attention to the distance from flam-
mable floor, which is also valid even if there are 
a steel, glass, stone or tile over flammable ma-
terials. It is the floor itself, which must be non-
flammable. (Concrete, tile or similar).

2.3 The chimney connection

The chimney opening must follow national and 
local regulations. However, the area of the ope-
ning should never be less than 175 cm

2

, which 

corresponds to a diameter of 150 mm. 

If  a  damper  is  fitted  in  the  flue  gas  pipe,  there 
must always be at least 20 cm

2

 of free passage, 

even  when  the  damper  is  in  its  “closed”  posi-
tion.

If local regulations permit, two contained stoves 
can be connected to the same chimney. How-
ever, you must abide by local regulations regar-
ding the distance between the two connections. 

The  Scan-Line  Prestige  insert  can  be  installed 
with a horisontal straight back outlet. Maximum 
length  of  the  pipe  should  be  500  mm  with  a 
5” diameter. Minimum draft of 13 pascal is re-
quired.

The insert stove must never be connected to
a chimney that is linked to a gas fire stove.

An efficient stove makes high demand on chimney 
properties – so always have your local chimney 
sweep evaluate your chimney.

Содержание Prestige A

Страница 1: ...UCTIONS PRESTIGE INSERT STOVE THE PRESTIGE PRESTIGE SCA SERIES IS EXEMPT FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD DANISH DESIGN DANISH QUALITY DANISH PRODUCTION www heta dk EN Prestige A P...

Страница 2: ...Dust 27 mg Nm3 Dust NS3058 3059 2 15 g kg OGC CEN TS 15883 81 mgC Nm3 at 13 O2 9 Fire safety Reaction to fire A1 Test of fire safety in connection with the burning of wood Approved Distance to combust...

Страница 3: ...ail heta heta dk Copyright 2014 Heta is a registered trademark of Heta A S 28 11 2019 0037 1485 Version 1 4 Printed in Denmark Subject to printing errors and changes Operating Instructions Contents Be...

Страница 4: ...dealers Neverthe less when in transport or handling damage of the often heavy stoves can occur It is important that upon receipt check your Heta product completely and report any damage or defects to...

Страница 5: ...el F lg fabrikantens brugervejledning Indsatsen m lslu es r ggas samleledning Tr 8 kW 312 C 0 085 27 mg Nm 2 15 g kg 79 109 mg Nm DOP Pres ge Indsats 2237 2016 Pres ge Indsats Produkt beskrivelse 1063...

Страница 6: ...A permanent amount of air will therefore enter the firebox to feed the fire producing negligible amounts of smoke and unburnt hydrocarbons The applian ces will only be considered as an exempt appli a...

Страница 7: ...minutes Once the fuel is Ignited Close the door and regulate the air back to ope rating air When the fire is well established you can now regulate the operating air to the desired combustion level No...

Страница 8: ...provide clean burning beautiful flame picture as well as achieving the rated efficiency There is a risk of smoke escaping into the room if the door is opened during vigorous firing or if there is a l...

Страница 9: ...eating value per kg which is about 5 27 kW hour for absolute dry wood Wood with a moistness of 18 has a efficiency of about 4 18 kW hour per kg and one litre heating oil contains about 10 kW hour CO2...

Страница 10: ...chamber is visible Too rapid combustion Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe i...

Страница 11: ...Qualified Technicia Maintenance Period Before Autum Daily 2 3 days 30 days 60 90 days 1st Year 2st Year Cleaning the chimney see Chimney C Cleaning the chimney and stove C C Cleaning the stoves fireb...

Страница 12: ...fore replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Removal sequence of stones Replace in reverse order Starting with Fig 8 7 1 3 4...

Страница 13: ...was carried out with the combustion air 40 1 19 Guarantee Heta wood stoves subjected to a strict quality control during production and before delivery to the dealer Therefore the stoves guarantee is F...

Страница 14: ...restige C 8 9 10 11 8 Prestige BR Prestige BL Prestige C 12 13 14 Prestige C 15 Prestige BR Prestige BL 16 Prestige A 17 18 19 20 21 23 24 25 26 27 28 x 2 29 30 31 32 33 34 35 Prestige BR Prestige BL...

Страница 15: ...m 22 0030 2609 Hinge 2 23 0008 9082 Cylinder pin 6x35 2 24 4013 0004 Start up air return spring 1 25 1513 0124 Closure mirrored 1 Pos No Name Qty 26 1513 0123 Closing System 1 27 1505 0084 Left hinge...

Страница 16: ...2 Installation instructions 17 2 1 Distance requirements 17 2 2 Floor 17 2 3 Chimney connection 17 2 4 Combustion air 18 2 5 Stovedrawings measurments 19 2 6 Fitting the flue collar 20 2 7 Clearances...

Страница 17: ...tention to the distance to flammable floor 330 mm which is also applicable although there is a steel glass plate on the floor If the floor is made of for ex concrete tile or similar there may not be c...

Страница 18: ...mm2 per kW output will be required 4 5 kW x 550 mm 2475 mm2 un less the stove is connected to an outside fresh air supply Connection to a brick chimney Brick a thimble into the chimney and seat the fl...

Страница 19: ...surments 752 501 463 464 294 705 169 731 501 505 294 186 708 464 480 731 501 480 464 294 186 708 505 501 710 480 464 294 186 505 Measurment Prestige A Measurment Prestige BR Measurment Prestige BL Mea...

Страница 20: ...sert without side windows 400 mm 7 Min 130 mm from top edge of convection outlet to a combustible material 8 Not combustible 12 5 0 36 W m K 9 Floor board Min 150 mm to combustible flooring to the sid...

Страница 21: ...BR BL 130 400 550 135 C N A N A 550 135 The dimensions are the minimum dimensions unless otherwise stated insulated flue pipe Applies to both right and left sides 5 6 2 1 9 10 3 7 Min 1080 cm2 Min 58...

Страница 22: ...ulite must be removed from the stove before mounting in the wall See on page 12 It is optional whether you want to mount the support rod1516 0007 See Fig 5 7 The cor ner must be removed if used suppor...

Страница 23: ...Prestige C Prestige A Prestige A 10 11 12 13 23 6 7 8 9 Prestige BR Prestige BL Prestige BR Prestige BL Prestige C Prestige BR BL C Prestige BR Prestige BL Prestige BR Prestige BL...

Страница 24: ...14 15 16 5 x M4x8 24 Prestige C Prestige C Prestige C 3 Connecting external air supply from below 2 x4 1 3 x4...

Страница 25: ...4 5 6 7 8 25 x4...

Страница 26: ...hinged door Model Prestige BR 8120 0100 with side window in the right side Left hinged door or right hinged door The Scan Line Prestige models Model Prestige BL 8120 0200 with side window in the left...

Страница 27: ...ction 15 of the Deregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Re gulatory Reform Scotland Act 2014 In Wales...

Страница 28: ...28...

Отзывы: