Gas Pressure Regulator 

 
A gas pressure regulator must be installed to regulate the proper flow of gas to the appliance. The regulator must 
be installed between the main gas supply line to the unit shut off valve and the appliance and must be accessible 
for servicing. Proper sizing of the regulator is extremely important, check the BTU rating of the appliance or 
appliances being regulated by the regulator.  
 

NOTE:  

Contact the factory for regulator sizing when multiple appliances are being installed in a line up or  

               

island suite configuration and are interconnected using the front manifold connections. 

 

 

NOTE:  

Gas pressure should be checked when the unit is installed and all other equipment on the same line is  

              

  on. The operating gas pressure must be the same as that specified on the rating plate. If necessary,  

                pressure adjustment may be made at the pressure regulator. 

 

 

  The appliance and its individual shutoff valve must be disconnected from the gas supply piping system     
  during any pressure testing of that system where pressures are in excess of .5 psig (3.45kpa).  

 

  When test pressures are .5 psig (3.45kpa) or less, the appliance must be isolated from the gas   
  supply system by closing its individual manual shutoff valve. 

 

Prior to lighting, check all joints in the gas supply line for leaks. Use soap and 
water solution. Do not use an open flame. After piping has  been checked for 
leaks, all piping receiving gas should be fully purged to remove air. 

 

Ventilation Air / Flue Connections 

 
The following notes are intended to give general guidance. For detailed recommendations, refer to the 
applicable codes in the Country, State, County and City of installation. 

 

Do not obstruct the flow of combustion and ventilation air. 

 

Proper ventilation is critical for optimum performance. The ideal method of ventilating gas fired equipment is 
the use of properly designed canopy that should extend six inches (152mm) beyond all sides of the appliance (s) 
and six feet six inches (1981mm) above the floor. Information on the construction and installation of ventilating 
hoods may be obtained from the standard for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest 
edition), available from the National Fire Protection Association, on their web site: http://www.nfpa.org/. 
 
A strong exhaust will create a vacuum in the room. For an exhaust vent to work properly, replacement air must 
be equal to the amount of air exhausted. An imbalance between exhaust and replacement air can cause 
degradation in the appliance’s performance. 
 
All gas burners and pilots need sufficient air to operate. Large objects should not be placed in front of the 
appliance(s) that would obstruct the flow of air into the front.  
 
 
 

NOTICE:

 

In the Commonwealth of Massachusetts all gas appliances vented by either mechanical systems 
or ventilation hoods shall comply with 248 CMR interlocking requirements. 

 
 
 

 
 

 
 

Содержание HFT Series

Страница 1: ...ercial Corporation 1 Owner s Guide Installation Operation French Top HFT Series Hestan Commercial Corporation 3375 E La Palma Ave Anaheim CA 92806 888 905 7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE...

Страница 2: ...L GAS SUPPLIER IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GAS...

Страница 3: ...r Installation 5 Statutory Regulations 5 United States of America 5 Canada 5 Gas Supply 6 Gas Pressure Regulator 7 Ventilation Air Flue Connections 7 Electrical Supply 8 Model Serial Rating Plate Loca...

Страница 4: ...nd clear of combustible materials Clearances The following minimum clearances must be followed COMBUSTIBLE NON COMBUSTIBLE Model BACK SIDE BACK SIDE French Top 4 4 0 0 NOTE For use on non combustible...

Страница 5: ...allation of this appliance must be carried out by a properly trained and qualified installer and in accordance with the relevant regulations codes of practice and the related publications of the Count...

Страница 6: ...olation valve is fitted or the automatic system can be reset this notice must be posted ALL DOWNSTREAM BURNER AND PILOT VALVES MUST BE TURNED OFF PRIOR TO ATTEMPTING TO RESTORE THE SUPPLY AFTER EXTEND...

Страница 7: ...water solution Do not use an open flame After piping has been checked for leaks all piping receiving gas should be fully purged to remove air Ventilation Air Flue Connections The following notes are i...

Страница 8: ...de Appliances equipped with a flexible electrical supply cord are provided with a three prong grounding plug It is imperative that this plug be connected into a properly grounded three prong receptacl...

Страница 9: ...operation 2 When gas is present turn the knobs to the OFF position Using a log lighter light the pilot s The pilot s can also be lit through pilot viewing holes 3 Wait 3 minutes turn all of the burne...

Страница 10: ...o not spray on due to open flame from pilot lights Apply cleaners with sponge or cloth heavy soil can be removed with a plastic cleaning pad or scraper Wipe surfaces with clean damp cloth to remove so...

Страница 11: ...ted or dirty Vent plugged on regulator or regulator installed improperly Negative pressure or unbalanced ventilation in kitchen creating drafts Low gas pressure to unit Slow to heat up not recovering...

Отзывы: