background image

©2015 Hestan Commercial Corporation 

 

Operating Instructions 

 

Lighting Instructions 

 

French Top Section 

 

1)

 

Remove  center ring, turn main gas supply on. Turn knobs to the “ON” position for 5 seconds, 
purging the air in the gas lines. If there is no gas present, wait 5 minutes and repeat the operation. 

2)

 

When gas is present turn the knobs to the “OFF” position. Using a log lighter, light the pilot(s). The 
pilot(s) can also be lit through pilot viewing holes.  

3)

 

Wait 3 minutes, turn all of the burners on and then off, one at a time, to make sure all of the lines have 
been purged of air. 

4)

 

Re-install center ring. 

 

 
For daily shutoff:  

Turn burner valve knob(s) to the “OFF” position, pilot(s) will remain on. 

 
 
 

A 5 minute complete shutoff period is 

 

required before the appliance is re-lighted

 

 

 
 
 
 
 
 
   

 

                     
 
 
 
 
 
 
 
 
 

 
 
 

Содержание HFT Series

Страница 1: ...ercial Corporation 1 Owner s Guide Installation Operation French Top HFT Series Hestan Commercial Corporation 3375 E La Palma Ave Anaheim CA 92806 888 905 7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE...

Страница 2: ...L GAS SUPPLIER IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GAS...

Страница 3: ...r Installation 5 Statutory Regulations 5 United States of America 5 Canada 5 Gas Supply 6 Gas Pressure Regulator 7 Ventilation Air Flue Connections 7 Electrical Supply 8 Model Serial Rating Plate Loca...

Страница 4: ...nd clear of combustible materials Clearances The following minimum clearances must be followed COMBUSTIBLE NON COMBUSTIBLE Model BACK SIDE BACK SIDE French Top 4 4 0 0 NOTE For use on non combustible...

Страница 5: ...allation of this appliance must be carried out by a properly trained and qualified installer and in accordance with the relevant regulations codes of practice and the related publications of the Count...

Страница 6: ...olation valve is fitted or the automatic system can be reset this notice must be posted ALL DOWNSTREAM BURNER AND PILOT VALVES MUST BE TURNED OFF PRIOR TO ATTEMPTING TO RESTORE THE SUPPLY AFTER EXTEND...

Страница 7: ...water solution Do not use an open flame After piping has been checked for leaks all piping receiving gas should be fully purged to remove air Ventilation Air Flue Connections The following notes are i...

Страница 8: ...de Appliances equipped with a flexible electrical supply cord are provided with a three prong grounding plug It is imperative that this plug be connected into a properly grounded three prong receptacl...

Страница 9: ...operation 2 When gas is present turn the knobs to the OFF position Using a log lighter light the pilot s The pilot s can also be lit through pilot viewing holes 3 Wait 3 minutes turn all of the burne...

Страница 10: ...o not spray on due to open flame from pilot lights Apply cleaners with sponge or cloth heavy soil can be removed with a plastic cleaning pad or scraper Wipe surfaces with clean damp cloth to remove so...

Страница 11: ...ted or dirty Vent plugged on regulator or regulator installed improperly Negative pressure or unbalanced ventilation in kitchen creating drafts Low gas pressure to unit Slow to heat up not recovering...

Отзывы: